• Title/Summary/Keyword: Nuclear Power Plant Performance

Search Result 500, Processing Time 0.032 seconds

Reactor Coolant Pump Seal Monitoring System Using Statistical Modeling Techniques (통계적모델을 이용한 원자로냉각재펌프 밀봉장치 성능감시)

  • Lee, Song-Kyu;Chung, Chang-Kyu;Bae, Jong-Kil;Ahn, Sang-Ha
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1386-1390
    • /
    • 2007
  • This paper presents the equipment condition monitoring technology for the process or the equipment using statistical techniques. The equipment condition monitoring system consists of an empirical model to estimate the expected sensor values of process variables and a diagnose model to detect the abnormal condition and to identify the root source of the problem. The empirical model is constructed by the analysis of historic data. The diagnose model uses the sequential probability ratio test (SPRT) technique. The monitoring system was tested with real operating data acquired from the Reactor Coolant Pump Seal in the Nuclear Power Plant. It can detect the system degradation or failure at the early stage since it is able to catch the subtle deviation of process variables from normal condition.

  • PDF

A Study on the Two Phase Flow in the Floor of Containment Building after a Loss of Coolant Accident (냉각재 상실사고 후 격납건물내의 이상유동 연구)

  • Bae, Jin-Hyo;Park, Man Heung;Koh, Chul-Kyun;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1274-1284
    • /
    • 1999
  • The Regulatory Guide 1.82 recommends an analysis of hydraulic performance for sump of ECCS (Emergency Core Cooing System) when LOCA(Loss of Coolant Accident) occurs in a nuclear power plant. The present study deals with 3-dimensional, unsteady, turbulent and two-phase flow simulation to examine the behavior of mixture of reactor coolant and debris near the floor of containment building in conjunction with appropriate assumptions. The dispersed solid model has been adjusted to the interfacial momentum transfer between reactor coolant and debris. According to the results, the counterclockwiserecirculation zone had been formed in the region between sump and connection aisle about 376 second after LOCA occurs. The debris thickness accumulated on a sump screen periodically increases or decreases up to 2000 second, afterwards its peak decreases.

The Experience of Non-destructive Examination of Equipments Welds in Nuclear Power Plant (원자력발전소 설비 용접부 비파괴검사 참여 경험)

  • 김영호;김형남;남민우;김용식;양승한
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.118-120
    • /
    • 2004
  • The non-destructive examinations for Yonggwang unit 6 was conducted in four different fields, these are 1)all non-destructive inspections for components, piping weldments and structures, 2)automated ultrasonic inspection for pressure vessels weldments. As the results, there were no big indications, and all indications detected during inspection were evaluated as the metallurgical and geometrical non-reinvent indications form weldments. Especially for the weldment of pipes, PD(Performance Demonstration) was applied as a UT inspection method according to 1995 edition of ASME code Sex. XI, this resulted in improvement of the reliability of UT inspection.

  • PDF

Fuzzy Linguistic Approach for Evaluating Task Complexity in Nuclear Power Plant (원자력발전소에서의 작업복잡도를 평가하기 위한 퍼지기반 작업복잡도 지수의 개발)

  • Jung Kwang-Tae;Jung Won-dea;Park Jin-Kyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.126-132
    • /
    • 2005
  • The purpose of this study is to propose a method to evaluate task complexity using CIFs(Complexity Influencing Factors). We developed a method that CIFs can be used in the evaluation of task complexity using fuzzy linguistic approach. That is, a fuzzy linguistic multi-criteria method to assess task complexity in a specific task situation was proposed. The CIFs luting was assessed in linguistic terms, which are described by fuzzy numbers with triangular and trapezoidal membership function. A fuzzy weighted average algorithm, based on the extension principle, was employed to aggregate these fuzzy numbers. Finally, the method was validated by experimental approach. In the result, it was validated that TCIM(Tink Complexity Index Method) is an efficient method to evaluate task complexity because the correlation coefficient between task performance time and TCI(Task Complexity Index) was 0.699.

Recent Corrosion Research Trends in Weld Joints

  • Kim, Hwan Tae;Kil, Sang Cheol;Hwang, Woon Suk
    • Corrosion Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.74-76
    • /
    • 2007
  • The increasing interest in the corrosion properties of weld joints in the corrosive environment is placing stringent demands on the manufacturing techniques and performance requirements, and the manufacture employs the high quality and efficiency welding process to produce welds. Welding plays an important role in the fabrication of chemical plants, nuclear power plant, ship construction, and this has led to an increasing attention to the corrosion resistant weld joints. This paper covers a recent technical trends of welding technologies for corrosion resistance properties including the COMPENDEX DB analysis of welding materials, welding process, and welding fabrications.

A Review on Measurement and Applications of Situation Awareness for an Evaluation of Korea Next Generation Reactor Operator Performance (상황인식에 대한 측정 및 차세대 원자로 운전원 성능 평가에서의 활용방법에 관한 이론 연구)

  • Lee, Dhong-Ha;Lee, Hyun-Chul
    • IE interfaces
    • /
    • v.13 no.4
    • /
    • pp.751-758
    • /
    • 2000
  • Situation awareness is defined as a person's perception of the elements of the environment within a volume of time and space, the comprehension of their meaning and the projection of their status in the near future. Situation awareness is important in attempting to evaluate human behavior in operating complex systems such as aircraft, air traffic control, and nuclear power plant systems. From the literatures this study reviews the relationship between situation awareness and numerous individual, system and environmental factors, and also reviews the methodologies for the empirical measurement of situation awareness applicable to Korea Next Generation Reactor (KNGR) design project. Attention, working memory, workload, stress, system complexity, and automation are presented as critical factors limiting operator's situation awareness. Mental models and goal-directed behavior are hypothesized as important mechanisms overcoming these limits. This study summarized hypothesized guidelines for interface design to improve situation awareness of reactor operators. Some of the guidelines should be tested in the KNGR evaluation experiments in the future.

  • PDF

A Study on the Concept of Operations and Improvement of the Design Methodology for the Physical Protection System of the National Infrastructure - Focused on Nuclear Power Plants - (국가기반시설 물리적 방호체계 운영개념 및 설계방법 개선방안 연구: 원자력발전소를 중심으로)

  • Na, Seog-Jong;Sung, Ha-Yan;Choi, Sun-Hee
    • Korean Security Journal
    • /
    • no.61
    • /
    • pp.9-38
    • /
    • 2019
  • As the scales & density of the Korean national infrastructures have been increased, they will be identified as rich and attractive potential targets for intensified North Korea's attack in the rear region and terrorism attack. In addition, due to changes in security environment such as drone threats and lack of security forces under the 52-hour workweek law, I think that it is the proper time point to reevaluate the effectiveness and appropriateness of the current physical protection system and its shift to a new system. In this study, the direction and improvement of the perimeter physical protection systems of the national infrastructures are to be studied from the viewpoints of its concepts of operations and design methodology, focusing on the nuclear power plant. The reason why we focus on nuclear power plants is because they cause wide-range and long-term damages caused by radioactive materials disperal and pollution, along with short-term damage caused by the interruption of electricity generation in the event of damage to nuclear power plants. With the aim of extracting improvement directions, as we will comprehensively review domestic research trends and domestic·overseas related laws, and consider Korea's specificity, we try to reframe the concept of operation - systematization, mobilization and flexibility -, and establish criteria on system change. In order to improve the technical performance of the new perimeter physical protection system, we study on high-fidelity·multi-methodology based integrated design methodology, breaking from individual silo-type design methods, and I suggest improvement of government procurement, its expansion to export business and other national infrastructure.

Study on Performance of Vertical-axis Tidal Turbines Applied to the Discharged Channel of Power Plant (조류발전용 수직축 터빈의 방수로 설치에 따른 성능에 관한 연구)

  • Lee, Jeong-Ki;Hyun, Beom-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.274-281
    • /
    • 2015
  • Thermal and nuclear power plants on shore commonly use the sea water for cooling facility. Discharged cooling water has the high kinematic energy potential due to amount of water flux. Numerical analysis was made to find the suitable combinations between the arrangement of tidal turbines and the overall dimensions of the discharged channel. Several parameters such as the turbine diameter to inlet size, and the axial distance to turbine size were investigated. Power coefficients for various test conditions were also compared to see the effect of inlet configurations such as single inlet and dual inlet. For the single inlet, the mean power coefficient appeared to be gradually decreased with increasing distance, and the maximum power was obtained when the turbine diameter was same as the inlet diameter. For the dual inlet, the tendency was similar so that the better result when the turbine diameter was same as the inlet diameter. It is expected that the present methodology can be extensively utilized to harness the high kinetic energy flow of the discharge channel of power plant.

An Analytical Study on Evaluation of Opening Performance of Steam Safety Valve for Nuclear Power Plant (원자력 증기용 안전밸브의 개방성능 평가를 위한 해석적 연구)

  • Sohn, Sangho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.1
    • /
    • pp.5-11
    • /
    • 2014
  • The purpose of this paper is to investigate an analytical approach for opening performance evaluation of the nuclear pressure safety valve based on standard codes such as ASME or KEPIC. It is well-known that safety valve is considered as one of pressure relief valves for protecting a boiler or pressure vessel from exceeding the maximum allowable working pressure. When pressure in a container reaches its set pressure, the safety valve commences discharging the internal fluid by a sudden opening called as popping. Safety valve is usually evaluated by set pressure, full open, blow-down, leakage and flow capacity. The test procedure and technical requirement for performance evaluation is described in international code of ASME code such as BPVC. The opening characteristics of steam safety valve can be analyzed by computational fluid dynamics (CFD) and steam shaft dynamics. First, the flow analysis along opening process is simulated by running the CFD models of the ten types of opening steps from 0 to 100%. As a analysis result, the various CFD outputs of flow pattern, pressure, forces on the disc and mass flow at each simulation step is demonstrated. The lift force is calculated by using the forces applied on disc from static pressure and secondary flow. And, the effect of huddle chamber or control chamber is studied by dynamic analysis based on CFD simulation results such as lift force. As a result, dynamics analysis shows opening features according to the sizes of control chamber.

Aspect of the chief of state guard EMP (Electro Magnetic Pulse) protection system for the consideration (국가원수 경호적 측면에서의 EMP(Electro Magnetic Pulse) 방호 시스템에 대한 고찰)

  • Jung, Joo-Sub
    • Korean Security Journal
    • /
    • no.41
    • /
    • pp.37-66
    • /
    • 2014
  • In recent years, with the development of computers and electronics, electronics and communication technology in a growing and each part is dependent on the cross-referencing makes all electronic equipment is obsolete due to direct or indirect damage EMP. Korea and the impending standoff North Korea has a considerable level of technologies related to the EMP, EMP weapons you already have or in a few years, the development of EMP weapons will complete. North Korea launched a long-range missile and conducted a nuclear test on several occasions immediately after, when I saw the high-altitude nuclear blackmail has been strengthening the outright offensive nuclear EMP attacks at any time and practical significance for the EMP will need offensive skills would improve. At this point you can predict the damage situation of Korea's security reality that satisfy the need, more than anything else to build a protective system of the EMP. The scale of the damage that unforeseen but significant military damage and socio-economic damage and fatalities when I looked into the situation which started out as a satellite communications systems and equipment to attack military and security systems and transportation, finance, national emergency system, such as the damage elsewhere. In General, there is no direct casualties reported, but EMP medical devices that rely on lethal damage to people who can show up. In addition, the State power system failure due to a power supply interruption would not have thought the damage would bring State highly dependent on domestic power generation of nuclear plants is a serious nuclear power plant accident in the event of a blackout phenomenon can lead to the plant's internal problems should see a forecast. First of all, a special expert Committee of the EMP, the demand for protective facilities and equipment and conduct an investigation, he takes fits into your budget is under strict criteria by configuring the contractors should be sifting through. He then created the Agency for verification of performance EMP protection after you have verified the performance of maintenance, maintenance, safety and security management, design and construction company organized and systematic process Guard facilities or secret communications equipment and perfect for the EMP, such as protective equipment maneuver system should take.

  • PDF