Reactor Coolant Pump Seal Monitoring System Using Statistical Modeling Techniques

통계적모델을 이용한 원자로냉각재펌프 밀봉장치 성능감시

  • 이송규 (한국전력기술(주) 원자로설계개발단) ;
  • 정장규 (한국전력기술(주) 원자로설계개발단) ;
  • 배종길 (한국수력원자력(주)) ;
  • 안상하 (한국과학기술원 원자력 및 양자공학과)
  • Published : 2007.11.15

Abstract

This paper presents the equipment condition monitoring technology for the process or the equipment using statistical techniques. The equipment condition monitoring system consists of an empirical model to estimate the expected sensor values of process variables and a diagnose model to detect the abnormal condition and to identify the root source of the problem. The empirical model is constructed by the analysis of historic data. The diagnose model uses the sequential probability ratio test (SPRT) technique. The monitoring system was tested with real operating data acquired from the Reactor Coolant Pump Seal in the Nuclear Power Plant. It can detect the system degradation or failure at the early stage since it is able to catch the subtle deviation of process variables from normal condition.

Keywords