• 제목/요약/키워드: Nozzle Space

검색결과 274건 처리시간 0.024초

초고압수에 의한 화강석절삭에 대한 연구 (A study on the slot cutting in granite by high speed water jet)

  • 선우춘;최병희
    • 터널과지하공간
    • /
    • 제4권2호
    • /
    • pp.92-101
    • /
    • 1994
  • Water jet has been employed in extraacton of minerals for many years but the applications of low pressure jent s ar emodfined to some fields. With increasing strength of equipment it is possible to consider the use of high speed water jets for cutting hard rock. The high speed water jet technology is applied to various engineering fiels such as precessing rocks, quarrying rocks, mechanical fracturing as wel as rock excavation under the sea. For slot cutting in rocks with high speed water jets it is necessary to establish the empirical formula for estiamation of the cutting depth. The cutting depth is influenced by cutting parameters such as driving pressure, traverse speed, standoff distance, and shape and diameter of nozzel. Tests were carried out with a variety of cutting parameters on three types of granite. Nozzle pressures ranged from 1,200 to 2,800 bar, traverse speeds from 0.45 to 10.38 cm/min, standoff distances from 4.5 to 13.5 mm, and three types of nozzle diameter were used.

  • PDF

화장실을 이용한 층별 피난공간 확보 기술개발 (Development of Technology to Secure Refuge Space by Using Existing Restroom)

  • 김지석;신현준;김정엽;박병직
    • 설비공학논문집
    • /
    • 제27권1호
    • /
    • pp.24-30
    • /
    • 2015
  • The fire on a high-rise building would possibly cause fatalities because of ineffective egress due to extended evacuation distance in huge building structure, coupled with dense population, thus requiring secured optimal evacuation method and space. The restroom located in the living space is considered to be useful refuge space which is built with wet pipe and noncombustible materials. This study aimed to develop a system that would make use of the existing restroom as a fire refuge space. Ventilation duct were installed to discharge odor during normal conditions. We could serve the air supply duct to also raise the air pressure in the restroom so as to prevent the toxic gas from gapping around the restroom. The nozzle for the water screen would be installed in restroom door facing the living room to form the water screen which would protect the door. This study is intended to replace the existing refuge space with the restroom in such a way as described above.

난방공간에서 에어커튼의 토출각도 변화에 따른 성능 변화 (Performance Variation of the Air Curtain for Various Discharge Angles in Feating Space)

  • 성순경
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.57-63
    • /
    • 2010
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. The discharge angle of air curtain is very important as the sealing efficiency is affected by it. This paper presents a performance of single jet air curtain in heating space when the discharge angle of nozzle changes. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A condition of discharge angle that has the highest sealing efficiency is proposed.

Preliminary Study of Micro Cold Gas Thruster

  • Moon, Seonghwan;Oh, Hwayollng;Huh, Hwanil
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.617-621
    • /
    • 2004
  • Miniaturization of subsystems including propulsion systems is recent trends in spacecraft technology. Small space vehicle propulsion is not only a technological challenge of a scaling system down, but also a combination of fundamental flow/combustion constraints. In this paper, physical constraints of micronozzle for cold gas micro-thruster are reviewed and discussed. Method to measure small thrust are also described.

  • PDF

Numerical Analysis of Flow Uniformity in Selective Catalytic Reduction (SCR) Process Using Computational Fluid Dynamics (CFD)

  • Shon, Byung-Hyun
    • International Journal of Advanced Culture Technology
    • /
    • 제10권3호
    • /
    • pp.295-306
    • /
    • 2022
  • The NOx removal performance of the SCR process depends on various factors such as catalytic factors (catalyst composition, shape, space velocity, etc.), temperature and flow rate distribution of the exhaust gas. Among them, the uniformity of the flow flowing into the catalyst bed plays the most important role. In this study, the flow characteristics in the SCR reactor in the design stage were simulated using a three-dimensional numerical analysis technique to confirm the uniformity of the airflow. Due to the limitation of the installation space, the shape of the inlet duct was compared with the two types of inlet duct shape because there were many curved sections of the inlet duct and the duct size margin was not large. The effect of inlet duct shape, guide vane or mixer installation, and venturi shape change on SCR reactor internal flow, airflow uniformity, and space utilization rate of ammonia concentration were studied. It was found that the uniformity of the airflow reaching the catalyst layer was greatly improved when an inlet duct with a shape that could suppress drift was applied and guide vanes were installed in the curved part of the inlet duct to properly distribute the process gas. In addition, the space utilization rate was greatly improved when the duct at the rear of the nozzle was applied as a venturi type rather than a mixer for uniform distribution of ammonia gas.

Urea-SCR용 스월 인젝터의 니들 리프트 형상에 따른 유동특성에 대한 연구 (Study on the Flow Characteristics of Urea-SCR Swirl Injector according to the Needle Lift Profile)

  • 곽은조;박성영
    • 한국산학기술학회논문지
    • /
    • 제17권6호
    • /
    • pp.650-655
    • /
    • 2016
  • 본 논문에서는 요소수를 적용하는 SCR 인젝터의 내부유동에 대한 전산 유동해석을 수행하였다. 유동해석에 적용된 인젝터는 경사진 노즐과 스월디스크를 갖는 스월타입의 단홀 인젝터이다. 인젝터 니들의 최대 리프트 및 열림 속도를 인젝터의 설계 변수로 선정하였다. 비정상 상태로 작동하는 노즐 내부의 유동 특성을 해석하기 위하여, 움직이는 물체에 적용이 가능한 Moving Grid 기법을 적용하여 정밀한 인젝터 니들의 움직임을 모사하였다. 유동해석 결과, 인젝터 니들의 속도가 증가할수록 출구를 통한 요소수 유량은 감소하는 것으로 나타났다. 이는 인젝터 니들의 속도가 빨라질수록, 인젝터 니들 하부의 빈 공간을 채우려는 유량이 증가하고, 이러한 요소수 유량의 증가가 노즐 출구로 방출되는 유량의 감소를 유발하게 된다. 요소수 유동이 인젝터 노즐에서 출구 쪽으로 진행할수록, 스월 유동은 감소하였다. 이는 유동과 노즐 벽면과의 마찰에 기인한 것으로 사료된다. 또한, 최대 리프트 유지기간에서, 니들 리프트가 높을수록 스월 계수와 평균 스월 계수가 증가하는 경향을 보였다. 본 연구의 결과는 관련된 Urea-SCR 인젝터의 기본 설계 자료로 활용될 수 있을 것이다.

차세대 인공위성 전기저항제트 가스추력기의 다물리 수치모사 (MULTI-PHYSICAL SIMULATION FOR THE DESIGN OF AN ELECTRIC RESISTOJET GAS THRUSTER IN THE NEXTSAT-1)

  • 장세명;최진철;한조영;신구환
    • 한국전산유체공학회지
    • /
    • 제21권2호
    • /
    • pp.112-119
    • /
    • 2016
  • NEXTSat-1 is the next-generation small-size artificial satellite system planed by the Satellite Technology Research Center(SatTReC) in Korea Advanced Institute of Science and Technology(KAIST). For the control of attitude and transition of the orbit, the system has adopted a RHM(Resisto-jet Head Module), which has a very simple geometry with a reasonable efficiency. An axisymmetric model is devised with two coil-resistance heaters using xenon(Xe) gas, and the minimum required specific impulse is 60 seconds under the thrust more than 30 milli-Newton. To design the module, seven basic parameters should be decided: the nozzle shape, the power distribution of heater, the pressure drop of filter, the diameter of nozzle throat, the slant length and the angle of nozzle, and the size of reservoir, etc. After quasi one-dimensional analysis, a theoretical value of specific impulse is calculated, and the optima of parameters are found out from the baseline with a series of multi-physical numerical simulations based on the compressible Navier-Stokes equations for gas and the heat conduction energy equation for solid. A commercial code, COMSOL Multiphysics is used for the computation with a FEM (finite element method) based numerical scheme. The final values of design parameters indicate 5.8% better performance than those of baseline design after the verification with all the tuned parameters. The present method should be effective to reduce the time cost of trial and error in the development of RHM, the thruster of NEXTSat-1.

액체로켓엔진에서 충돌형 분사기 형태의 연료과잉 가스발생기 연소특성 (Combustion Characteristics of Fuel-rich Gas Generator with Impinging Injector for a Liquid Rocket Engine)

  • 한영민;김승한;이광진;문일윤;설우석;이창진
    • 한국항공우주학회지
    • /
    • 제33권6호
    • /
    • pp.64-70
    • /
    • 2005
  • 본 논문에서는 충돌형 분사기를 장착한 연료 과잉 가스발생기에서 수행한 설계점 및 탈설계점 연소시험의 전반적인 결과에 대하여 논하였다. 가스발생기는 충돌형 분사기와 추진제 공급 메니폴드로 구성된 분사기 헤드, 물냉각 채널을 가진 연소실, 혼합을 증가시키는 turbulence ring, 온도 및 압력을 측정하는 링, 그리고 노즐로 구성되었다. 여러 운영조건에서 연소시험은 성공적이었으며 가스발생기 손상은 발생하지 않았다. 체류시간 4~6msec 정도에는 출구온도변화가 거의 없었지만 압력변동에 따라 출구온도는 변하였다. 측정되는 압력, 유량 그리고 노즐목 크기로 계산한 연소효율는 출구에서 측정한 온도의 제곱근에 비례하는 관계식을 저 혼합비 가스발생기에서도 갖고 있었다. 가스발생기의 O/F 비 변화에 가장 민감하게 출구온도가 변화하였으며 이에 대한 관계식을 도출하여 향후 설계 기초 자료로 활용되게 하였다.

전산유체역학을 이용한 아폴로 달착륙선 하강엔진의 플룸 거동 연구 (Plume Behavior Study of Apollo Lunar Module Descent Engine Using Computational Fluid Dynamics)

  • 최욱;이균호;명노신
    • 한국항공우주학회지
    • /
    • 제45권9호
    • /
    • pp.766-774
    • /
    • 2017
  • 달착륙선 하강엔진에서 사출된 배기가스가 월면과 충돌할 때 배기가스와 월면과의 상호작용으로 인해 월면에 분포되어 있는 표토가 분산된다. 이때, 분산된 표토입자가 착륙선과 충돌할 경우 성능 저하 등과 같은 역효과를 야기할 수 있다. 따라서 본 연구에서는 달착륙 엔진의 배기가스 거동을 전산유체해석을 통해 예측하고자 하였다. 하강엔진의 노즐내부 영역은 Navier-Stokes 방정식 기반의 연속체 유동 모델을 이용하여 해석하였으며, 노즐 외부 배기가스 거동은 연속체 유동 모델과 직접모사법(DSMC)을 적용하여 해석한 결과를 각각 비교 및 분석하였다. 이를 통해 진공환경에서 달착륙선 하강엔진에 대한 최적의 배기가스 해석 절차를 수립할 수 있었으며, 차후 한국형 달착륙선 개발에 충분히 활용할 수 있을 것으로 기대된다.

사출성능 개선을 위한 사출용 가스발생기 연구 (Research on the Ejection Gas Generator to Improve Ejecting Performance)

  • 오석진;장승교;차홍석
    • 한국항공우주학회지
    • /
    • 제41권5호
    • /
    • pp.383-390
    • /
    • 2013
  • 유도탄의 사출성능 중 탄에 충격으로 작용하는 최대가속도의 감소는 유도탄의 비정상작동 방지와 내부 부품들의 크기 및 비용 감소 측면에서 매우 중요하다. 본 연구에서는 사출용 가스발생기의 작동에 의해 탄에 가해지는 최대가속도가 사출초기에 발생됨을 착안하여 사출초기에 영향을 미치는 설계인자를 조사하였다. 가스발생기 설계인자로 점화기 및 노즐마개를 선정하고, 설계인자 변경을 통해 가스발생기에 의해 발생되는 최대가속도를 실험적으로 조사하였다. 최종적으로 최대가속도 감소효과를 정량적으로 비교하기 위해 가스발생기 지상연소시험을 실시하였다. 그 결과 설계인자의 최적값들이 적용된 개선모델의 경우 기준모델에 비해 최대가속도를 약 68% 줄일 수 있음을 확인하였다.