• Title/Summary/Keyword: Nozzle Extension

Search Result 30, Processing Time 0.021 seconds

Determination of Ignition Squence and Estimation of Injector Life Extension Technique in Liquid Rocket Engine (소형 액체 로켓 엔진에서의 점화 시퀀스 결정 및 인젝터 수명 연장 기법 평가)

  • Park, Jeong;Kim, Yong-Wook;Kim, Young-Han; Moon, Il-Yoon;Lee, Jae-Yong;Kang, Sun-Il;Chung, Yong-Gahp;Cho, Nam-Kyung;Oh, Seung-Hyup
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.1
    • /
    • pp.43-53
    • /
    • 2000
  • Experimental studies on determination of the supply leading time of propellants to combustion chamber have been made to stably and efficiently guarantee the ignition process with liquid rocket engine. The propellant used is a Jet A-1 as fuel and a liquid oxygen as oxidizer. Unlike impinging FOOF type of injectors are arranged radially and the designed O/F ratio is 2.34. The present experiment program also includes the stability on the quadlet type of ignitor using the triethylalumimum as an ignition source and injector life tests. Experimental results clarifies that the propellant supply through LOx leading to combustion chamber is proper for stable ignition and combustion processes based on the fuel and oxidizer manifold pressures, combustion chamber pressure, and the variation of flame length from the nozzle exit with lapse time, and shows that the leading supply time of propellants affects the engine performance little. The effect of positioning cooling holes is remarkable to protect the injector face.

  • PDF

Performance Assessment of Two Horizontal Shroud Tidal Current Energy Converter using Hydraulic Experiment (수리실험을 통한 수평 2열 쉬라우드 조류에너지 변환장치 성능평가)

  • Lee, Uk-Jae;Choi, Hyuk-Jin;Ko, Dong-Hui
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.34 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • In this study, the two horizontal shroud tidal current energy converter, which can generate power even under low flow speed conditions, was developed. In order to determine the shape of the shroud system, a three-dimensional numerical simulation test was conducted, and a 1/6 scale down model was made to perform a hydraulic model experiment. The hydraulic model experiment was performed under four flow conditions, and the flow speed, torque, and RPM were measured for each experimental case. As a result of the numerical simulation test, it was found that the flow speeds passing through the nozzle were increased by about 2~3 times in the cylinder, and when the extension ratio was 2:1, the highest flow speed was shown. In addition, it was found that the flow speeds increased 2.8 times when the diameter ratio between the nozzle and the cylinder was 1.5:1. Meanwhile, as a result of the hydraulic model experiment, it was found that when the tip speed ratio was between 1.75 and 2, the power coefficient was 0.32 to 0.34.

Investigation of Characteristics for Cooling Parameters of a Combustor in Liquid Rocket Combustors (재생냉각 연소기의 냉각기구에 따른 특성 파악)

  • Kim, Hong-Jip;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.5
    • /
    • pp.45-50
    • /
    • 2010
  • Thermal analyses have been performed to study the effect of location of fuel ring and thermal barrier coatings in regenerative cooling channels in a full-scale combustor. For the effective cooling, the fuel ring has better be installed near axial location of the low expansion ratio and low heat flux, and branching of cooling channels is preferable. Also, the radiative cooled nozzle extension is thought to be reasonable for the cooling of combustor walls. Among the possible coatings, $Y_2O_3$ stabilized $ZrO_2$ coating and Ni/Cr coating have been adopted. Compared with Ni/Cr coating which has high oxidation resistance, $Y_2O_3$ stabilized $ZrO_2$ coating, one of ceramic coatings is found to be much effective to sustain the thermal survivability of combustion walls.

Eco-friendly Control of Whiteflies by Two-Fluid Fogging System (이류체 포그시스템을 이용한 친환경적 가루이 방제)

  • Kim, Sung-Eun;Lee, Sang-Don;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.120-126
    • /
    • 2012
  • Two experiments were designed and executed to measure the effectiveness of the two-fluid fogging system in controlling whiteflies in tomato cultivation. The two-fluid fogging system that lowers temperature and raises humidity in greenhouses provides an eco-friendly method of preventing damages from whiteflies. The first experiment elucidated the effect of fogging treatment on the elimination of whiteflies and investigated the sectional distribution of whiteflies. The second experiment analyzed the vertical distribution, the motility of whiteflies and reduction of the number of whiteflies under the fogging system. The result of the experiments showed that the fogging system lowered the number of whiteflies and decreased their motility significantly. It affected the vertical distribution of whiteflies as well. Based on these experiments, we strongly recommend using the fogging system to prevent and control whiteflies in greenhouses, in addition to installing yellow sticky traps in the areas that have the highest density of whiteflies.

Control of Bemisia tabaci by Two-Fluid Fogging System (이류체 포그시스템을 활용한 가루이 방제)

  • Kim, Sung-Eun;Lee, Sang-Don;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.394-398
    • /
    • 2011
  • The effect of two-fluid fogging system on the control of Bemisia tabaci in tomato cultivation was evaluated in a greenhouse. The number of Bemisia tabaci was decreased by 87% from the fog treatment for 7 days. During the fog treatment, the mean daily temperature was decreased by $2^{\circ}C$ and the mean daily relative humidity was increased by 3~4% as compared to the non-treatment. The reduction of Bemisia tabaci in the treatment might not be resulted from the differences in temperature and humidity in the greenhouse. The sound coming from the two-fluid fogging system did not affect when it was operated without water inside. Therefore it was concluded that water droplets coming out the nozzle reduced the growth and the movement of whiteflies because the suspension of tiny water droplets were attached on the skin of whiteflies.

Regenerative Cooling Characteristics for Cooling Parameters of a Combustor in Liquid Rocket Combustors (재생냉각 연소기의 냉각기구에 따른 냉각 특성 파악)

  • Kim, Hong-Jip;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.145-149
    • /
    • 2010
  • Thermal analyses have been performed to study the effect of location of fuel ring and thermal barrier coatings in regenerative cooling channels in a full-scale combustor. For the effective cooling, the fuel ring has better be installed near axial location of the low expansion ratio and low heat flux, and branching of cooling channels is preferable. Also, the radiative cooled nozzle extension is thought to be reasonable for the cooling of combustion walls. Among the possible coatings, $Y_2O_3$ stabilized $ZrO_2$ coating and Ni/Cr coating have been adopted. Compared with Ni/Cr coating which has high oxidation resistance, $Y_2O_3$ stabilized $ZrO_2$ coating, one of ceramic coatings is found to be much effective to sustain the thermal survivability of combustion walls.

  • PDF

A study on the optimization design of pulse air jet system to improve bag-filter performance (여과집진기의 탈진 성능 향상을 위한 충격 기류 분사 시스템 최적화 설계에 관한 연구)

  • Hong, Sung-Gil;Jung, Yu-Jin;Park, Ki-Woo;Jeong, Moon-Heon;Lim, Ki-Hyuk;Suh, Hye-Min;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3792-3799
    • /
    • 2012
  • The dedusting characteristics of pulse air jet type dedusting system which is widely applied in the industries were identified by utilizing the computational fluid dynamics (CFD) and the dedusting performance in modified shape of dedusting unit was compared in this study. The review on the dedusting air volume, air stream distribution and inflow velocity distribution on each shape of dedusting part showed that the case of installing the nozzle on the blow tube (Case-3) and the case of installing the double intaking tube to the venturi (Case-4 and Case-5) were more excellent than the structure (Case-1) which is widely applied in the field in its amplification effect on the air volume and extension of stream width. The specification of venturi was decided to apply the selected Case-5 for the option of the commercial back filter. It is considered that the dedusting air volume will be maintained in maximum in the case of 50 mm and 90 mm for the diameter of internal and external intaking pipe respectively.

Conceptual Design of a LOX/Methane Rocket Engine for a Small Launcher Upper Stage (소형발사체 상단용 액체메탄 로켓엔진의 개념설계)

  • Kim, Cheulwoong;Lim, Byoungjik;Lee, Junseong;Seo, Daeban;Lim, Seokhee;Lee, Keum-Oh;Lee, Keejoo;Park, Jaesung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.4
    • /
    • pp.54-63
    • /
    • 2022
  • A 3-tonf class liquid rocket engine that powers the upper stage of a small launcher and lifts 500 kg payload to 500 km SSO is designed. The small launcher is to utilize the flight-proven technology of the 75-tonf class engine for the first stage. A combination of liquid oxygen and liquid methane has been selected as their cryogenic states can provide an extra boost in specific impulse as well as enable a weight saving via the common dome arrangement. An expander cycle is chosen among others as the low-pressure operation makes it robust and reliable while a specific impulse of over 360 seconds is achievable with the nozzle extension ratio of 120. Key components such as combustion chamber and turbopump are designed for additive manufacturing to a target cost. The engine system provides an evaporated methane for the autogenous pressurization system and the reaction control of the stage. This upper stage propulsion system can be extended to various missions including deep space exploration.

Proper Application Concentration of Oleic Acid for Eco-friendly Control of Whiteflies by Two-fluid Fogging System in Greenhouses (이류체 포그 시스템을 이용한 친환경적 가루이 방제시 올레산의 적정 농도)

  • Kim, Sung Eun;Lee, Sang Don;Lee, Moon Haeng;Sim, Sang Youn;Kim, Young Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.3
    • /
    • pp.299-304
    • /
    • 2012
  • In this work, we experimented with the two-fluid fogging system that eco-friendly prevents whiteflies in greenhouses in order to find the optimal concentration of oleic acid supplied through the system and to evaluate the control value of three consecutive treatments. The first experiment, which was to find the optimal concentration of oleic acid, used "Dotaerang Gold" tomatoes grown in stand-alone plastic greenhouse at Buyeo Tomato Experiment Station. We tested three levels of concentration of oleic acid, which were 0, 2000, and 4000 ppm. The second experiment, which was to evaluate the control value of three consecutive treatments of oleic acid, used "Rokusanmaru" tomatoes grown in Venlo type glasshouse at Gyeonggi-Do Agricultural Research & Extension Services. In this experiment, oleic acid of 2000 ppm was applied three times with two days intervals. The number of whiteflies was counted 2 two days after the last application of oleic acid. Even when oleic acid was not being applied, the two-fluid fogging system was run from 9:00 am to 5:00 pm whenever the temperature is higher than $25^{\circ}C$ or the humidity is lower than 75%. In the first experiment, the control value was 81.6% with 2000 ppm of oleic acid and 93.6% with 4000 ppm. It means that the higher the concentration is, the greater the control value. In the second experiment, 2000 ppm treatment resulted in 85.8% of the control value, which is higher than the required standard for insecticides. Hence, spraying oleic acid with the concentration of 2000 ppm three times with two days intervals turned out to be a very effective in the eco-friendly prevention of whitefly.

Herbicidal Phytotoxicity under Adverse Environments and Countermeasures (불량환경하(不良環境下)에서의 제초제(除草劑) 약해(藥害)와 경감기술(輕減技術))

  • Kwon, Y.W.;Hwang, H.S.;Kang, B.H.
    • Korean Journal of Weed Science
    • /
    • v.13 no.4
    • /
    • pp.210-233
    • /
    • 1993
  • The herbicide has become indispensable as much as nitrogen fertilizer in Korean agriculture from 1970 onwards. It is estimated that in 1991 more than 40 herbicides were registered for rice crop and treated to an area 1.41 times the rice acreage ; more than 30 herbicides were registered for field crops and treated to 89% of the crop area ; the treatment acreage of 3 non-selective foliar-applied herbicides reached 2,555 thousand hectares. During the last 25 years herbicides have benefited the Korean farmers substantially in labor, cost and time of farming. Any herbicide which causes crop injury in ordinary uses is not allowed to register in most country. Herbicides, however, can cause crop injury more or less when they are misused, abused or used under adverse environments. The herbicide use more than 100% of crop acreage means an increased probability of which herbicides are used wrong or under adverse situation. This is true as evidenced by that about 25% of farmers have experienced the herbicide caused crop injury more than once during last 10 years on authors' nationwide surveys in 1992 and 1993 ; one-half of the injury incidences were with crop yield loss greater than 10%. Crop injury caused by herbicide had not occurred to a serious extent in the 1960s when the herbicides fewer than 5 were used by farmers to the field less than 12% of total acreage. Farmers ascribed about 53% of the herbicidal injury incidences at their fields to their misuses such as overdose, careless or improper application, off-time application or wrong choice of the herbicide, etc. While 47% of the incidences were mainly due to adverse natural conditions. Such misuses can be reduced to a minimum through enhanced education/extension services for right uses and, although undesirable, increased farmers' experiences of phytotoxicity. The most difficult primary problem arises from lack of countermeasures for farmers to cope with various adverse environmental conditions. At present almost all the herbicides have"Do not use!" instructions on label to avoid crop injury under adverse environments. These "Do not use!" situations Include sandy, highly percolating, or infertile soils, cool water gushing paddy, poorly draining paddy, terraced paddy, too wet or dry soils, days of abnormally cool or high air temperature, etc. Meanwhile, the cultivated lands are under poor conditions : the average organic matter content ranges 2.5 to 2.8% in paddy soil and 2.0 to 2.6% in upland soil ; the canon exchange capacity ranges 8 to 12 m.e. ; approximately 43% of paddy and 56% of upland are of sandy to sandy gravel soil ; only 42% of paddy and 16% of upland fields are on flat land. The present situation would mean that about 40 to 50% of soil applied herbicides are used on the field where the label instructs "Do not use!". Yet no positive effort has been made for 25 years long by government or companies to develop countermeasures. It is a really sophisticated social problem. In the 1960s and 1970s a subside program to incoporate hillside red clayish soil into sandy paddy as well as campaign for increased application of compost to the field had been operating. Yet majority of the sandy soils remains sandy and the program and campaign had been stopped. With regard to this sandy soil problem the authors have developed a method of "split application of a herbicide onto sandy soil field". A model case study has been carried out with success and is introduced with key procedure in this paper. Climate is variable in its nature. Among the climatic components sudden fall or rise in temperature is hardly avoidable for a crop plant. Our spring air temperature fluctuates so much ; for example, the daily mean air temperature of Inchon city varied from 6.31 to $16.81^{\circ}C$ on April 20, early seeding time of crops, within${\times}$2Sd range of 30 year records. Seeding early in season means an increased liability to phytotoxicity, and this will be more evident in direct water-seeding of rice. About 20% of farmers depend on the cold underground-water pumped for rice irrigation. If the well is deep over 70m, the fresh water may be about $10^{\circ}C$ cold. The water should be warmed to about $20^{\circ}C$ before irrigation. This is not so practiced well by farmers. In addition to the forementioned adverse conditions there exist many other aspects to be amended. Among them the worst for liquid spray type herbicides is almost total lacking in proper knowledge of nozzle types and concern with even spray by the administrative, rural extension officers, company and farmers. Even not available in the market are the nozzles and sprayers appropriate for herbicides spray. Most people perceive all the pesticide sprayers same and concern much with the speed and easiness of spray, not with correct spray. There exist many points to be improved to minimize herbicidal phytotoxicity in Korea and many ways to achieve the goal. First of all it is suggested that 1) the present evaluation of a new herbicide at standard and double doses in registration trials is to be an evaluation for standard, double and triple doses to exploit the response slope in making decision for approval and recommendation of different dose for different situation on label, 2) the government is to recognize the facts and nature of the present problem to correct the present misperceptions and to develop an appropriate national program for improvement of soil conditions, spray equipment, extention manpower and services, 3) the researchers are to enhance researches on the countermeasures and 4) the herbicide makers/dealers are to correct their misperceptions and policy for sales, to develop database on the detailed use conditions of consumer one by one and to serve the consumers with direct counsel based on the database.

  • PDF