• Title/Summary/Keyword: Nose

Search Result 1,633, Processing Time 0.036 seconds

A Study on the Heat Transfer Performance of an Energy-Nose Section in a Household Refrigerator-Freezer (가정용 냉장고의 에너지 노즈부 열전달 특성에 관한 연구)

  • Lee, Moo-Yeon;Lee, Dong-Yeon;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.6 s.261
    • /
    • pp.574-580
    • /
    • 2007
  • The objective of this article is to present an analysis of all heat transfer paths through the energy nose under closed door conditions when refrigeration system of household refrigerator-freezer is operating on. Both experimental and numerical methods are suggested as a means of determining the overall energy nose load amount as well as the load due to each pathway such as mullion section and F and R sides of the household refrigerator-freezer. In other words, all loads determined in this article are just energy nose and not the loads seen by the refrigeration system. We suggest good ideas for improving the heat transfer losses such as conduction and convection through the energy nose. As we can be known from the experimental test results, it is effective to prevent the heat loss of a mullion section. And energy efficiency is also decreased approximately 6% compared to that of a baseline sample test result. As we can be known from the Ansys 8.1 analysis, it is shown the steady state temperature distribution in figures from 6 to 8. And the direction of the heat flow through the energy nose section is also easily seen from that In conclusion, the article is focused on an energy nose section in household refrigerator-freezer for practical proposes which is the energy saving in a household refrigerator-freezer. And the method suggested may be applied to any make or model to aid in the search for high efficient energy nose section of household side by side refrigerator-freezer as well as top mounted refrigerator-freezer, commercial refrigerator and so on.

Association of Nose Size and Shapes with Self-rated Health and Mibyeong (코의 크기 및 형태와 자가건강, 미병과의 상관성)

  • Ahn, Ilkoo;Bae, Kwang-Ho;Jin, Hee-Jeong;Lee, Siwoo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.35 no.6
    • /
    • pp.267-273
    • /
    • 2021
  • Mibyeong (sub-health) is a concept that represents the sub-health in traditional East Asian medicine. Assuming that the nose sizes and shapes are related to respiratory function, in this study, we hypothesized that the nose size and shape features are related to the self-rated health (SRH) level and self-rated Mibyeong severity, and aimed to assess this relationship using a fully automated image analysis system. The nose size features were evaluated from the frontal and profile face images of 810 participants. The nose size features consisted of five length features, one area feature, and one volume feature. The level of SRH and the Mibyeong severity were determined using a questionnaire. The normalized nasal height was negatively associated with the self-rated health score (SRHS) (partial ρ = -0.125, p = 3.53E-04) and the Mibyeong score (MBS) (partial ρ = -.172, p = 9.38E-07), even after adjustment for sex, age, and body mass index. The normalized nasal volume (ρ = -.105, p = 0.003), the normalized nasal tip protrusion length (ρ = -.087, p = 0.014), and the normalized nares width (ρ = -.086, p = .015) showed significant correlation with the SRHS. The normalized nasal area (ρ = -.118, p = 0.001), the normalized nasal volume (ρ = -.107, p = .002) showed significant correlation with the MBS. The wider, longer, and larger the nose, the lower the SRHS and MBS, indicating that health status can be estimated based on the size and shape features of the nose.

The study of determination proper nose properties, used for I..L.M constructing economic long spans bridge. (경제성과 장대경간 구성을 구현할 수 있는 I.L.M교량에 사용되는 추진코의 적정제원 산정에 관한 연구)

  • 박상현;이승주;김찬녕;심재수;황의승
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.853-858
    • /
    • 2001
  • The PSC bridge being built by ILM may have greater bending moment during its construction rather than after completion. When it occurs, Engineer should suggest to reduce stress-resultants than to make bigger cross-section with considering stability ,economics, and proper span-to-depth ratio. The used method is to install extruded nose at the end of girder. It substitutes the weighted segment for the light. From the reference, the stiffness of extruded nose, is 1/10 of the main girder, and the length is 60 to 70% of the length of the span, with little justification. In this study, the proper length and stiffness of the nose element is determined by the parametric study and idealizing procedure. The results about the extruded nose through the mixing of the parameter of its stiffness and length, the proper length of extruded nose is 80% of the longest span and the proper stiffenss is 13% of the bending stiffness of the superstructure and the proper length of extruded nose is 70% of the longest span and the proper stiffness is 9.5% of the bending stiffness of the superstructure.

  • PDF

Dynamics of a Projectile with a Passive Moveable Nose (가변탄두를 갖는 발사체의 동역학에 대한 기초연구)

  • Lee Hyun-Chang;Park Woo-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.308-313
    • /
    • 2006
  • The extent of impact dispersion is a function of parameters including gun geometry and tolerances, the foe control system, projectile manufacturing tolerances, etc. The study here investigates potential impact point accuracy improvement for a projectile realized by replacing the rigid nose cone wind screen with a passive nose. Toward this end, a nose projectile dynamic model is derived which consists of the standard six degrees of freedom similar to a rigid projectile plus three additional degrees of freedom associated with rotation of the nose with respect to the main projectile body. By Observing the pitch and yaw movement of the nose in the simulation results, it is believed to be possible to reduce the effects of uncertainties which is occurred at firing step.

  • PDF

Application of Electronic Nose in Biotechnology (바이테크놀로지 분야에서의 전자코 이용)

  • Lim, Chae-Lan;Noh, Bong-Soo
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.401-408
    • /
    • 2007
  • It's not easy to detect the specific compounds from various compounds that fermented in bioreactor. The electronic nose was an instrument, which comprised of an array of electronic chemical sensors with partial specificity and an appropriate pattern recognition system, capable of recognizing simple or complex volatiles. It can conduct fast analysis and provide simple and straightforward results and is best suited for quality control and process monitoring in field of biotechnology. This review examined the application of electronic nose in biotechnology and brief explanation of its principle. In this minireview numbers of applications of an electronic nose in biotechnology include monitoring fermentation process, to overcome interference with alcohol, and to detect contaminant microorganism were discussed. The electronic nose would be useful for a wide variety of biotechnology when correlating analytical instrumental data with the obtained data from electronic nose.

Implementation of a Portable Electronic Nose System for Field Screening (필드 스크린을 위한 휴대용 전자코 시스템의 구현)

  • Byun, Hyung-Gi;Lee, Jun-Sub;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.41-46
    • /
    • 2004
  • There is currently much interest in the development of instruments that emulate the senses of humans. Increasingly, there is demand for mimicking the human sense of smell, which is a sophisticated chemosensory system. An electronic nose system is applicable to a large area of industries including environmental monitoring. We have designed a protable electronic nose system using an array of commercial chemical gas sensors for recognizing and analyzing the various odours. In this paper, we have implemented a portable electronic nose system using an array of gas sensors for recognizing and analyzing VOCs (Volatile Organic Compounds) in the field. The accuracy of a portable electronic nose system may be lower than an instrument such as GC/MS (Gas Chromatography/Mass Spectrometer). However, a portable electronic nose system could be used on the field and showed fast response to pollutants in the field. Several different algorithms for odours recognition were used such as BP (Back-Propagation) or LM-BP (Levenberq-Marquardt Back-Propagation). We applied RBF (Radial Basis Function) Network for recognition and quantifying of odours, which has simpler and faster compared to the previously used algorithms such as BP and LM-BP.

Correction of Saddle Nose Deformity using Autogenous Cartilage Graft (자가연골이식을 이용한 안장코의 교정)

  • Cheon, Ji Seon;Kim, Gyu Bo;Yang, Jeong Yeol;Shin, Myung Seok;Lee, Seung Chan
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.81-87
    • /
    • 2007
  • Purpose: Correction of saddle nose remains problematic both in the technique of reconstruction and in the choice of implant material for nasal augmentation. A large variety of graft materials have been used for the reconstruction of the saddle nose deformity. The purpose of this study is to determinate an algorithm for deciding alternative graft materials used in correction of saddle nose deformity. Methods: Six patients with saddle nose who were corrected using by auricular cartilage and costal cartilage at Chosun university hospital were analyzed. Results: After a mean interval of 12 months, all patients were satisfied with the esthetic and functional result. Conclusion: Auricular cartilage is an excellent graft material for esthetic and functional reconstruction of mild to moderate saddle nose deformity.

The Effects of Tribulus terrestris on Model of Allergic Rhinitis (백질여(白蒺藜)가 알레르기 비염 유발 동물 모델에 미치는 영향)

  • Chou, Ching-Yu;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.24 no.2
    • /
    • pp.28-34
    • /
    • 2011
  • Background & Objectives : Allergic rhinitis is an inflammation or irritation of the mucous membranes that line the nose. Common symptoms include sneezing, a stuffy or runny nose, itchy eyes, nose and throat, and watery eyes. We aimed to determine therapeutic effects of Tribulus terrestris by observing changes of total IgE level and the scratching or rubbing around the nose behavior. Materials and Methods : Fifteen BALB/c mice were divided into three groups : AR group(allergic rhinitis elicitated), TT group(which ate herbal medicine) and AH group(which ate antihistamine). Allergic rhinitis was induced in the three groups by intraperitoneal and intranasal sensitization with 0.1% ovalbumin solution. Then Tribulus terrestris was orally administered only to the TT group of 28days, while the AH group was given antihistamine. We observed changes of total IgE level and the scratching or rubbing around the nose behavior. We used Kruskal-Wallis test statistically(p<0.05). Results : 1. Tribulus terrestris showed significantly decreased IgE level on the serum of the rat model. 2. Tribulus terrestris showed significantly decreased scratching or rubbing around the nose behaviors of the rat model. Conclusion : According to the above results, it is considered that Tribulus terrestris has an inhibitory effect on the process of allergic rhinitis and it can be used in relieving symptoms of allergic rhinitis.

Improved Vapor Recognition in Electronic Nose (E-Nose) System by Using the Time-Profile of Sensor Array Response (센서 응답의 Time-Profile 을 이용한 전자 후각 (E-Nose) 시스템의 Vapor 인식 성능 향상)

  • Yoon Seok, Yang
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.329-334
    • /
    • 2004
  • The electronic nose (E-nose) recently finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. The odor recognition performance of E-nose can be improved by manipulating the sensor array responses of vapors in time-profile forms. The different chemical interactions between the sensor materials and the volatile organic compounds (VOC's) leave unique marks in the signal profiles giving more information than collection of the conventional piecemal features, i.e., maximum sensitivity, signal slopes, rising time. In this study, to use them in vapor recognition task conveniently, a novel time-profile method was proposed, which is adopted from digital image pattern matching. The degrees of matching between 8 different vapors were evaluated by using the proposed method. The test vapors are measured by the silicon-based gas sensor array with 16 CB-polymer composites installed in membrane structure. The results by the proposed method showed clear discrimination of vapor species than by the conventional method.

A portable electronic nose (E-Nose) system using PDA device (개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발)

  • Yang, Yoon-Seok;Kim, Yong-Shin;Ha, Seung-Chul;Kim, Yong-Jun;Cho, Seong-Mok;Pyo, Hyeon-Bong;Choi, Chang-Auck
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.