Linear Energy Transfer Dependence Correction of Spread-Out Bragg Peak Measured by EBT3 Film for Dynamically Scanned Proton Beams

  • Lee, Moonhee;Ahn, Sunghwan;Cheon, Wonjoong;Han, Youngyih
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.135-144
    • /
    • 2020
  • Purpose: Gafchromic films for proton dosimetry are dependent on linear energy transfers (LETs), resulting in dose underestimation for high LETs. Despite efforts to resolve this problem for single-energy beams, there remains a need to do so for multi-energy beams. Here, a bimolecular reaction model was applied to correct the under-response of spread-out Bragg peaks (SOBPs). Methods: For depth-dose measurements, a Gafchromic EBT3 film was positioned in water perpendicular to the ground. The gantry was rotated at 15° to avoid disturbances in the beam path. A set of films was exposed to a uniformly scanned 112-MeV pristine proton beam with six different dose intensities, ranging from 0.373 to 4.865 Gy, at a 2-cm depth. Another set of films was irradiated with SOBPs with maximum energies of 110, 150, and 190 MeV having modulation widths of 5.39, 4.27, and 5.34 cm, respectively. The correction function was obtained using 150.8-MeV SOBP data. The LET of the SOBP was then analytically calculated. Finally, the model was validated for a uniform cubic dose distribution and compared with multilayered ionization chamber data. Results: The dose error in the plateau region was within 4% when normalized with the maximum dose. The discrepancy of the range was <1 mm for all measured energies. The highest errors occurred at 70 MeV owing to the steep gradient with the narrowest Bragg peak. Conclusions: With bimolecular model-based correction, an EBT3 film can be used to accurately verify the depth dose of scanned proton beams and could potentially be used to evaluate the depth-dose distribution for patient plans.

의학물리 분야에 사용하기 위한 PMCEPT 몬테카를로 도즈계산용 코드 검증 (Verification of the PMCEPT Monte Carlo dose Calculation Code for Simulations in Medical Physics)

  • 금오연
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.21-34
    • /
    • 2008
  • 환자의 CT자료를 기반으로 만들어진 3차원상의 표적물질에 전자 및 광자의 전달 현상을 계산하는 몬테카를로(MC) 도즈계산용 병렬프로그램 (PMCEPT 코드)을 개발하여 베어울프 PC 클러스터에 탑제하였다. 시뮬레이션에서 오차를 최소화하고 코드를 더욱 발전시키기 위해서는 현재의 MC 코드의 한계를 아는 것이 매우 유익하다. 이러한 관점에서 저자는 PMCEPT코드를 이용하여 이질 혹은 동질의 표적물질에서 표준화된 깊이 도즈를 계산하여 잘 알려진 다른 코드들, MCNP5, EGS4, DPM, GEANT4 및 실험결과와 비교를 하였다. PMCEPT결과는 이질 혹은 동질의 표적에서 다른 코드들과 $1{\sim}3%$ 오차 범위 안에서 잘 일치하였다. 계산시간 비교에 있어서도 PMCEPT 코드가 MCNP5 보다는 약 20배, GEANT4코드보다는 약 3배정도 빨랐다. 이러한 결과를 종합하면, PMCEPT코드는 의학물리분야의 시뮬레이션 코드로 사용하기에 매우 좋은 것으로 사료된다.

  • PDF

Co-60에 의한 전신조사시 선량분포 (Dose Distribution of Co-60 Photon Beam in Total Body Irradiation)

  • Kang, Wee-Saing
    • 한국의학물리학회지:의학물리
    • /
    • 제2권2호
    • /
    • pp.109-120
    • /
    • 1991
  • 골수이식을 받게 될 환자의 이상 골수를 완전히 죽이기 위해 MV 정도의 선질의 광자선에 의한 전신방사선요법이 시행되고 있다. 국소방사선요법에 이용되고 있는 방사선치료장치에 의한 일상적인 방법으로 환자의 전선에 걸쳐 방사선을 조사하기에는 조사면의 크기가 훨씬 미치지 못한다. 그래서 환자의 전선에 걸쳐 방사선을 조사할 수 있는 방법이 개발되어야 한다. 방사선 전신조사를 위한 여건이 병원에 따라 다를 것이기 때문에 병원에 따라 독특한 방법이 개발될 수 있다. 서울대학교병원에서는 코발트치료기 만이 두부를 기울일 수 있어서 전신조사에 이용될 수 있다. 코발트치료기의 두부를 밖으로 90$^{\circ}$ 기울일 때 선축은 수평이고 또한 맞은편 벽과 직각이 된다. 이 때 선원에서 맞은편 벽가지 거리는 319cm 이였다. 벽에서 환자의 중앙시상면까지 간격을 40cm라고 가정할 때, 중앙시상면에서 명목상 최대 조사면 크기가 122cm$\times$122em 이였고, 조사선량 분포를 측정한 결과로는 130cm$\times$129cm 이였으며 상하방향에서는 대칭이 아니였다. 환자가 쭈그리고 앉은 자세를 취한다면 조사면의 크기는 전신조사를 시행할 수 있을 정도로 충분히 크다. 환자 좌우폭의 평균을 30cm 라고 가정하고, 중앙시상면에서 선원쪽 15cm 위치에 기준표면 (SSD는 264cm, 명목상 조사면 크기 115.5cm$\times$155.5cm)을 두고 단면의 크기가 25cm$\times$25cm이고 두께가 30cm 인 폴리스티렌 팬톰에서 평판형 전리함으로 PDD를 측정하였다. 최대선량점의 깊이는 0.3cm 이였고 표면선량율은 82%, 50% 깊이는 16.9cm였다. 대향조사시 선축상 선량분포는 중점의 선량에서 10%이내로 일치하였다. SCD를 279cm. 최대 조사면, 기준깊이 15cm 에 대한 TPR 을 폴리스티렌 팬톰에서 깊이 10cm 에서 20cm 에 걸쳐 측정하였다 . 측정범위에서 TPR 은 직선성을 보였다. 인체팬톰의 최대 전단면(coronal plane) 에 있는 각 구멍에 TLD 조각을 넣고, 코발트 선원에서 팬톰의 시상면까지 거리를 279cm 되게 하고 선축은 팬톰의 27번 절편과 28번 절편의 접변과 최대 전단면의 교차선과 일치시켜 양방향에서 15분씩 조사하여 전단면에서 선량을 측정하였다. 팬톰내 선축상 중앙점의 선량을 기준으로 다른 부위의 선량을 비교하였다. 두경부와 복부, 폐의 하반에서 선량의 차이는 $\pm$ 10% 이내였고, 폐의 상반과 어깨와 골반 부위에서 선량은 10%이상 저선량을 보였다. 특히 어깨부위에는 30%이상 저선량을 보였다. 이로부터 서울대병원과 유사한 조건에서 코발트로 전신조사하는 경우에는 폐나 두경부에 대응하는 조직보상체를 이용하기보다는 어깨부위에 선량을 추가하는 것이 바람직할 것이라고 생각한다.

  • PDF

전신방사선조사(TBI)시 다이오드 측정기(Diode detector) 및 열형광선량계(TLD)를 이용한 골조직 선량감쇄에 대한 고찰 (A study on dose attenuation in bone density when TBI using diode detector and TLD)

  • 임현실;이정진;장안기;김완선
    • 대한방사선치료학회지
    • /
    • 제15권1호
    • /
    • pp.67-77
    • /
    • 2003
  • I. 목적 전신방사선조사(TBI)시 균등한 선량을 조사할 목적으로 사용되는 각 신체부위별 보상체(compensator) 두께의 결정은 열형광선량계(TLD)를 이용하여 표면선량(surface dose)를 측정하고, 심부선량(depth dose)으로 환산하는 방법을 주로 이용한다. 그러나 이와 같은 방법은 골(bone) 조직에 대한 선량감쇄(dose attenuation)의 영향이 고려되지 않아 신체중심부에서의 정확한 심부선량을 알 수가 없다. 이에 본 연구에서는 열형광선량계와 다이오드측정기(Diode detector)로 표면선량과 심부선량을 동시에 측정하여 골조직에서의 선량감쇄 영향을 알아보고자 한다. II. 대상 및 방법 실험은 본원에서 TBI 치료를 받은 5명의 환자를 대상으로 실시하였으며, 측정장비로는 Siemens Mevatron 10MV X-ray, TLD(Harshaw 5500), Diode detector(Sun Nuclear)를 사용하였다. 선량 조사방법은 복부의 배꼽(umblicus)를 중심으로 하여 이문대향법(Bilateral)으로 150cGy가 조사되도록 하였다. 측정방법은 열형광선량계로 두부, 경부, 대퇴부, 슬관절, 족관절, 부위의 표면선량을 측정하였으며, 이 가운데 대퇴부, 슬관절, 족관절에서는 중심부 선량측정이 가능하여 동시에 심부선량을 측정하였다. 또한 실험대상자 중 3명의 환자는 상기와 같은 부위(두부, 경부, 대퇴부, 슬관절, 족관절)에 다이오드측정기로 심부선량을 측정하였다. III. 결과 TLD로 측정한 표면선량을 심부선량으로 환산한 값은 두부, 경부, 대퇴부, 슬관절, 족관절에서 각각 $92.78{\pm}3.3,\;104.34{\pm}2.3,\;98.03{\pm}1.4,\;99.9{\pm}2.53,\;98.17{\pm}0.56$ 이었고, 중심부 심부선량 측정이 가능한 대퇴부, 슬관절, 족관절에서는 각각 $86{\pm}1.82,\;93.24{\pm}2.53,\;91.50{\pm}2.84$로 나타났다. 따라서 표면선량과 중심부 심부선량 비교가 가능한 대퇴부, 슬관절, 족관절에서의 TLD의 측정치를 비교해보면 부위에 따라 최소 $6.67\%{\sim}$ 최대 $11.65\%$까지 골조직에 의한 선량감소가 나타나는 것을 알 수가 있다. 또한, Diode detector로 측정한 심부선량 값은 두부, 경부, 대퇴부, 슬관절, 족관절에서 각각 $95.23{\pm}1.18,\;98.33{\pm}0.6,\;93.5{\pm}1.5,\;87.3{\pm}1.5,\;86.90{\pm}1.16$으로 나타났으며, TLD로 측정한 대퇴부, 슬관절, 족관절에서의 표면선량과 비교했을 때 부위에 따라 최소 $4.53\%{\sim}$ 최대 $12.6\%$ 까지 차이를 보였다. 그리고 골조직에 의한 선량감쇄의 영향이 적은 복부(배꼽)에서는 열형광선량계 및 다이로드측정기로 측정한 값이 각각 $101.58{\pm}0.95,\;104.77{\pm}1.18$로 큰 차이가 없었다. IV 결론 전신방사선조사시 표면선량을 측정하여 심부선량으로 환산한 값은 골조직의 감쇄영향을 고려하지 못하므로 다이로드측정기(Diode detector) 또는 열형광선량계(TLD)로 중심부선량을 직접 측정하는 것이 중요하다. 그러나 중심부의 심부선량을 직접 측정할 수 없을 경우에는 골조직의 감쇄영향을 고려하여 복부배꼽에서의 선량보다 $5\%{\sim}10\%$ 정도의 선량이 초과 조사되도록 보상물질의 두께를 적절하게 조절하는 것이 필요할 것으로 사료된다.

  • PDF

6MV X-선에 대한 조직 보상체의 제작 및 응용에 관한 연구 (A Study on Design and Application of Tissue Compensator for 6MV X-rays)

  • 채규영;최은경;정웅기;강위생;하성환;박찬일
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.123-132
    • /
    • 1989
  • A radiation beam incident on an irregular or sloping surface produces the non-uniformity of absorded dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator is designed based on the patient's three dimensional contour. After required compensator thickness was determined according to tissue deficit at $25cm\pm25cm$ field size, 10cm depth for 6MV x-rays, tissue deficit was mapped by isoheight technique using laser beam system. Compensator was constructed along the designed model using 0.8mm lead sheet or 5mm acryl plate. Dosimetric verification were peformed by film dosimetry using humanoid phantom. Dosimetric measurements were normalized to central axis full phantom readings for both compensated and non-compensated field. Without compensation, the percent differences in absorbed dose ranged as high as $12.1\%$ along transverse axis, $10.8\%$ along vertical axis. With the tissue compensators in place, the difference was reduced to $0\~43\%$ Therefore, it can be concluded that the compensator system constructed by isoheihnt technique can produce good dose distribution with acceptible inhomogeneity, and such compensator system can be effectively applied to clinical radiotherapy.

  • PDF

고정형쐐기(Physical Wedge)와 동적쐐기(Dynamic Wedge)의 조사야 주변 선량에 관한 연구 (A Study of Peripheral Doses for Physical Wedge and Dynamic Wedge)

  • 민제순;나경수;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제19권2호
    • /
    • pp.77-82
    • /
    • 2007
  • 목 적: 목적: 2D-ARRAY chamber를 이용하여 고정형쐐기(Physical wedge filter)와 동적쐐기(Dynamic wedge)의 조사야 주변의 선량을 비교하여 평가하였다. 대상 및 방법: 고체팬텀위에 2D-ARRAY seven29 (PTW, Germany) chamber를 이용하여 조사야 10$\times$10, SSD 90 cm로 고정시키고 에너지는 6 MV와 15 MV로 변화시켜 5 mm 깊이의 조사야 밖 선량을 측정하였다. 쐐기필터15$^\circ$, 45$^\circ$동적쐐기와 선형가속기에 장착된 동적쐐기의 15$^\circ$, 45$^\circ$를 측정하여 조사야 끝에서 쐐기의 heel부분과 toe부분의 1 cm 되는 지점에서 5 cm 지점까지의 1 cm 간격으로 주변선량을 비교, 분석하였다. 선량은 최대선량지점에 대한 표면에 근접한 5 mm 깊이와 5 cm 깊이의 백분율로 선량값을 얻었다. 결 과: 6 MV 에너지는 동적쐐기가 고정형쐐기보다 조사야 주변 선량이 0.1$\sim$1.4%정도 모두 낮았다. 15 MV 에너지는 조사야에서 근접한 거리에서 동적쐐기의 선량이 0.4$\sim$0.9%정도 높지만 멀어지면서 급격하게 감소하여 동적쐐기가 최대 1.6% 낮게 측정되었다. 경사각 15$^\circ$와 45$^\circ$에서의 선량차이는 크지 않았으며, 동적쐐기는 heel 부분과 toe부분의 선량차이가 없는 반면 고정형쐐기는 에너지가 크고 쐐기 각도가 클수록 heel부분 보다 toe부분의 선량이 2%정도 높게 측정되었다. 결 론: 동적쐐기와 고정형 쐐기가 조사야 내에서는 같은 선량분포를 갖는 반면 조사야 주변에서는 동적쐐기가 고정형쐐기보다 선량이 낮았다. 따라서 동적쐐기를 사용할 경우 치료주위선량을 감소시킬 수 있으므로 치료부위와 근접한 표면에 가까운 주요장기의 선량을 최소화 할 수 있으며, 치료시간도 단축시킬 수 있었다.

  • PDF

흡수선량지수결정(吸收線量指數決定)에 관한 실험적(實驗的) 연구(硏究) (Experimental Study on the Determination of Absorbed dose Index)

  • 전재식;노재식;노성기;하정우;유영수;이현덕
    • Journal of Radiation Protection and Research
    • /
    • 제7권1호
    • /
    • pp.34-48
    • /
    • 1982
  • 본 연구의 일차적 목적은 방사선 방호를 위하여 임의지점(任意地點)의 주변 방사선량의 수준을 특성(特性)짓는 방법의 하나로 ICRU가 정의(定義)한 흡수선량지수를 실측(實測)하는데 있는 바 이를 위한 실험은 에비실험과 본 실험의 두 단계로 나누어 수행하였다. 예비단계의 실험에서는 30cm 지름의 polyethylene구(球)를 사용한 반면 본 실험에서는 인체조직등가물질(人體組織等價物質)의 구(球)를 제작하였으며 두 실험 모두 $^{137}Cs$$^{60}Co$ 감마선장(線場)과 TRIGA Mark-II 원자로의 열중성자(熱中性子) column의 중성자공장(中性子工場)에서 행하여졌다. 감마선 흡수선량측정에는 TCD-700 $(^{7}LiF)$ chip을, 중성자선량측정에는 Au 방사화박(放射化薄)과 함께 TLD chip도 사용하였는데 이 경우에는 감마선의 기여를 판별해 내기 위하여 TLD-600 $(^{6}LiF)$과 TLD-700을 동시에 사용하였다. 감마선 조사(照射)의 경우 구(球) phantom내(內) 흡수선량의 이론적 해석은 Burlin의 공동이론(空洞理論)에서 유도된 Erlich의 방법을 썼으며, 중성자 선량해석에는 fluence-KERMA 변환방법을 사용하였다. 이들 선량에 관하여서는 특히 자세히 설명하였다. 해석에 실험결과는 모두 통계적으로 처리 분석하였으며 특히 심부선량분포(深部線量分布)는 규격화(規格化)한 값을 사용하여 도표(圖表)로 나타내는 한편, 결론에서는 방사선방호용 지수량(指數量) 실측(實測)의 가능성과 난점(難點)을 설명하고 해결하여야 할 문제점들을 언급(言及)하였다.

  • PDF

Bolus를 대체하기 위해 자체 제작된 선량상승영역 변환기를 투과한 광자선의 특성 (Characteristics of Photon Beam through a Handmade Build-Up Modifier as a Substitute of a Bolus)

  • 김성준;이승준;문수호;설기호;이정은
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.225-232
    • /
    • 2014
  • 본 논문에서는 자체 제작된 선량상승영역 변환기(build-up modifier, BM)을 투과하는 high energy photon beam의 심부선량백분율(PDD)을 특성을 측정하고 이 결과를 토대로 BM 산란인자(BM scatter factor, $S_{BM}$)를 계산하였다. 다양한 조건에서 BM scatter가 PDD의 Build-up region에 미치는 영향을 평가하고 BM의 유용성을 알아보는 것이 본 연구의 목적이다. $S_{BM}$는 BM을 사용하지 않은 SFS 30 mm에서 측정된 산란인자의 값을 1로서 정규화 하였다. 가장 큰 SFS 200 mm의 경우, 6 MV 광자선을 사용할 때 $S_{BM}$는 두께에 따라 각각 1.331, 1.519, 1.598, 1.641, 그리고 1.657이었다. 10 MV 광자선에는 각각 1.384, 1.662, 1.825, 1.913, 그리고 2.001이었다. BM의 효과는 bolus의 최대 76% 효율을 가지는 것으로 나타났다. Bolus를 밀착시키기 어려운 특정적 부위에 대해 BM은 그 대안으로써 효과적인 장치가 될 수 있을 것으로 기대된다.

선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰 (Evaluation of Dosimetric Characteristics of Small Field in Cone Versus Square Fields Based on Linear Accelerators(LINAC) for Stereotactic Radiosugery(SRS))

  • 윤준;이귀원;박병문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권1호
    • /
    • pp.61-66
    • /
    • 2010
  • 선형가속기를 기반으로 하는 뇌정위적 방사선 수술에 있어 전용 콘과 동일한 정방형 조사면에서의 소조사면 선량특성에 관해 알아보고자 6 MV 광자선과 소조사면 전용 검출기를 이용해 측정하였다. 선원 표면간 거리는 100 cm로 하고, 전용 cone ${\Phi}1\;cm$, ${\Phi}2\;cm$, ${\Phi}3\;cm$과 정방형 조사면 $1{\times}1\;cm^2$, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$ 조사면 으로 1.5 cm, 5 cm, 10 cm, 20 cm, 30 cm 지점에서 심부선량을 측정하였고, 최대 선량점에서 각 조사면에서 출력선량을 측정하여 비교하였다. 반음영의 측정을 위한 선량측면도 측정은 ${\Phi}1\;cm$, ${\Phi}3\;cm$ 및 동일한 정방형 조사면에서 선원 표면간 거리 95 cm, 깊이 5 cm에서 SFD를 이용하여 측정하였다. 물리학적 조사면(90%) 내에서는 1 mm 간격으로, 반음영 영역(20~80%)에서는 0.5 mm 간격으로 측정하였다. 전용 콘 과 정방향 조사면의 PDD 변화는 기준조사면을 기준으로 5 cm 깊이에서 4.3~7.9% 낮게 나타났으며, 콘의 크기와 조사면 크기가 커질수록 PDD 변화는 적게 나타났다. 선질 비교를 위해 $PDD_{20,10}$를 비교한 결과 ${\Phi}1\;cm$ 콘과 $1{\times}1\;cm^2$을 제외한 다른 조사면에서는 1% 이내의 변화를 보였다. 출력선량은 콘을 이용한 방법에서 정방형 조사면에서 보다 3.1~4.6% 출력선량이 증가하였다. 반음영 영역은 ${\Phi}1\;cm$, ${\Phi}3\;cm$ 동일한 정방형 조사면에서 콘을 이용한 방법이 반음영 영역이 20% 감소하였다. 뇌정위적 방사선 수술은 소조사면을 이용해 1회 대선량을 조사하는 방법으로 조사면의 선량특성을 고려한 처방이 중요하게 된다. 본 실험을 통해 뇌정위적 방사선 수술에 있어 정방형 소조사면 보다 전용 콘을 이용한 방법이 유효하다고 사료되며, 향후 다양한 측정기를 이용한 소조사면의 선량특성에 관한 연구가 필요하다고 생각된다.

4-, 6-, 10-MV X-선원에서 공기동이 흡수선량에 미치는 효과 : 후두모형 (Air Cavity Effects on the Absorbed Dose for 4-, 6- and 10-MV X-ray Beams : Larynx Model)

  • 김창선;양대식;김철용;최명선
    • Radiation Oncology Journal
    • /
    • 제15권4호
    • /
    • pp.393-402
    • /
    • 1997
  • 목적 : 공기동을 포함한 병소 부위에 X-선원을 조사할 경우 공동과 근접한 영역에서의 저흡수선량 효과는 잘 알려져 있다. 공기-연조직 사이의 불균질면의 한 예로 후두 모형 즉, 조직 둥가물질과 그 사이에 삽입되어 있는 공기동을 만들었다. 본 연구에서는 방사선의 선질 조사면의 크기 공기동의 크기에 따른 공동 가까이에서의 흡수선량의 변화를 살펴보았다. 대상 및 방법 : 4-, 6-, 10-MV X-선원을 이용하여 2cm(폭)$\times$L(cm, 길이)$\times$2cm(높이)인 공기동을 포함한 후두 모형의 아크릴 팬톰에 대하여 흡수선량을 측정하였다. 흡수선량의 측정장비로 평행판전리함과 전리계를 이용하였다. 제작한 후두의 기하학적 치수는 상부 연조직$\cdot$공기동$\cdot$하부 연조직의 두께가 각각 4-, 2-, 4-cm이었다. 공기동이 없이 균일한 연조직 팬톰에 대한 공기동이 있는 경우의 흡수선량의 비(O/E)를 공기 공동-연조직의 경계로부터 거리를 변화시키면서 측정하였다. 표준화된 중강곡선과 최대흡수선량에 대한 입사면 반대쪽 표면에서의 흡수선량의 비를 초사면의 크기를 변화시키면서 측정하였다. 공기동의 크기에 따른 효과를 알기 위하여 여러 가지 조사면에 대하여 투영된 크기가 4cm(폭)$\times$L인 공기동의 높이(Z)를 변화시켜서 측정하였다. 결과 : 4-MV선원에서 $5cm\times5cm$ 이상의 조사면에서는 저흡수선량 효과가 없었다. 6-이나 10-MV선원에서 작은 조사야 즉, $4cm\times4cm$$5cm\times5cm$에서는 후두에 저흡수선량 부위가 나타났으며 $6cm\times6cm$ 이상의 조사면에서는 이 효과가 관찰되지 않았다. 선원의 선질이 증가할수록 저흘수선량인 조직층이 증가하였고 이때 표면 흡수선량의 크기는 변하지 않았다. 조사면의 크기가 $4cm\times4cm$에서 $8cm\times8cm$로 증가할 때 최대흡수선량에 대한 입사면 반대쪽의 공기동의 표면 선량은 4-, 6-, 10-MV 선원에서 각각 0.95, 0.92, 0.91에서 0.99로 증가하였다. 6-이나 10-MV 선원에서 공기동 표면에서의 흡수선량은 $5cm\times5cm$ 조사면에 있어서 예상값보다 각각 2-, 3-퍼센트의 감소가 있었고 또 4-MV에서는 감소효과를 발견할 수 없었다. $4cm\timesL\timesZ$ 공기동에서 그높이(Z)를 0.6에서 4.8cm까지 변화시켰을 때 조사면의 크기가 $8cm\times8cm$에서 공동의 크기에 무관하게 O/E>1.0이 관찰되었다. 결론 : 조사면내 공기동에 의한 저흘수선량 효과는 방사선의 선질$\cdot$조사면의 크기$\cdot$공기동의 크기에 의존된다. 이상의 연구 결과에서 고선질 선원이 공동을 포함한 병소 특히, 종양이 공기동의 표면까지 미치는 부위에 조사될 째 특별한 주의가 필요함을 알 수 있다. 이 경운 가능하면 조사되는 부위가 저전량이 되지않도록 저선질의 선원(예를 들면, 4-MV)을 쓰고 또 조사면을 넓혀야한다. 6-이나 10-MV 등의 고선질의 X-선을 쓰는 경우에는 조사면의 부위에 저선랸 부위가 생기므로 한번의 추가 조사를 더 시행할 필요가 있다.

  • PDF