• Title/Summary/Keyword: Normal tension

Search Result 355, Processing Time 0.026 seconds

Experimental Study on the Material Properties of Unreinforced Masonry (비보강 조적조의 재료특성 평가에 관한 실험연구)

  • 박진호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.178-185
    • /
    • 2000
  • A set of tests were accomplished in order to get better insight of the basic material properties of masonry made of normal concrete brick and different type of mortar compositions. Three different types of test were performed. Masonry unit and prism were tested by compressive strength test, Masonry wallets were tested by compressive strength test. Masonry wallets were tested in diagonally under tension. A significant influence of different mortar compositions on compression strength of masonry prism was observed, The tests have shown that for diagonal compression three different mode of failure were possible : tension crack along the loaded diagonal sliding along a mortar joint and combined sliding and diagonal crack according to the adhesive strength of a mortar.

  • PDF

Development and Decay of Columnar Vortex in Two Phases Interface; Gas/Liquid, Solid/Liquid (기/액, 고/액 2상 경계면에서의 수직와류의 성장과 소멸)

  • Kim, K.H.;Yang, S.Y.;Park, M.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.241-246
    • /
    • 2001
  • Vortices terminating at free surface have been investigated extensively. Most of investigations, however, are focused on surface parallel vortices and little has been known about surface normal vortex or columnar vortex. Visualized experimental results utilizing LIF technique are discussed for the purpose of characterization of columnar vortex interacting with a clean and a contaminated free surfaces and a solid body interface in the present investigation. The results reveal that surface tension changes due to surface contamination although bulk viscosity remains constant and eventually the behavior of a columnar vortex interacting with a contaminated free surface and a solid body interface are totally different from the clean free surface case.

  • PDF

Nonlinear Fracture Analysis of Polymer-Impregnated Concrete Flextural Members (폴리머침투콘크리트 휨부재의 비선형 파괴해석)

  • 변근주;이상민;유동우;김태진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.202-207
    • /
    • 1992
  • The objective of this study is to develop analytical techniques of polymer impregnated concrete flexural members for its proper applications. crystalline methylmethacrylate(MMA) is chosen as a monomer of polymer impregnants, On the basis of members. fracture toughness, fracture energy , critical crack width, and tension softening relations near crack tip are formulated in terms of member depth, initial notch length and the flexural strength of normal concrete. The structural analysis rocedure and the finite element computer program developed in the study are applicable to evaluate elastic behavior, ultimate strength, and tension softening behavior of MMA type PIC structural members subject to various loading conditions. It is concluded that the developed structural analysis procedure and the finite element computer program are applicable to analysis and design of in-situ and precast PIC structural members.

  • PDF

Uniaxial tension behavior of high ductile fiber reinforced mortar designed based on micromechanics (마이크로 역학에 의하여 설계된 고인성 섬유복합 모르타르의 1축인장 거동)

  • Kim, Yun-Yon;Kim, Jeong-Su;Kim, Hee-Sin;Kim, Jin-Keun;Ha, Gee-Joo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.284-287
    • /
    • 2004
  • A high ductile fiber reinforced mortar has been developed by employing micromechanics-based design procedure. Micromechanical analysis was initially performed to properly select water-cement ratio, and then optimal mixture proportion was determined based on workability considerations, including desirable fiber dispersion without segregation. Subsequent direct tensile tests revealed that the fiber reinforced mortar exhibited high ductile uniaxial tension property, represented by $1.8\%$ strain capacity, which is around 100 times the strain capacity of normal concrete.

  • PDF

A study on the protection system in electrified railways system (전철시스템에서의 보호시스템에 관한 연구)

  • Lee, Hee-Yong;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1342-1346
    • /
    • 2004
  • Recently, the load increasement and regenerative system of electrified railway system make a difficult to distinguish between the load current and fault current and it need a new intelligent protection system. The failure of traction system cause collapse of the other systems from high tension current. The over current from abnormal situation produces high tension current flow, high temperature are, voltage instability and current cutting, and break down railway systems. Protective system of traction system playa role of which detect and isolate failure points. In this paper, we proposed intelligent algorithm for discriminating normal and abnormal situation instead of the system being operated abnormally.

  • PDF

Design and Construction of Flat Slab using Unbonded Post-tension System (비부착 포스트텐션 플랫 슬래브의 설계와 시공)

  • Chung, Kwang-Ryang;Park, Jung-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.91-96
    • /
    • 2011
  • The flat slab is well-known as a structural system to reduce the story height, so it is broadly used for recent building. However, the normal RC flat slab is not appropriate for the long span, and the quantity of reinforcement bar and concrete is raised. Recently, the post-tensioning system has been introduced and used widely as an alternative method. Nevertheless, in Korea, it is not used broadly due to lack of the understanding and field experience. Especially, the post-tensioning system is hesitated to use due to uncertainty of construction ability and economics. This paper will introduce applicability to site and economics of unbonded post-tensioning system through construction examples.

  • PDF

A method for incompressible free surface flow including surface tension using CSF model (CSF 모델을 이용한 자유표면 유동 해석)

  • Hong I. C.;Baek J. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.15-18
    • /
    • 2004
  • A numerical method for simulating two-phase flows including surface force is presented. The method is based on fractional step method of finite volume formulation and the interface is tracked with PLIC VOF method. In the CSF model, as color function, f, representing the location of interface varies steeply in the interface region, we need to use smoothed function f to get accurate unit normal and the curvature. Peskin kernel is used to get smoothed function f. A spherical drop in static equilibrium and three-dimensional merging of gas bubble are tested, resulting in the validation of this method

  • PDF

Experiments on Columnar Vortex with Free Surface using LIF (Laser Induced Fluorescence) Technique (유동가시화를 통한 자유표면과 와류 수직반응에 대한 실험적 연구)

  • Kim, S.W.;Kim, K.H.;Lee, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.734-739
    • /
    • 2000
  • Vortices terminating at free surface have been investigated extensively. Most of investigations, however, are focused on surface parallel vortices and little has been known about surface normal vortex or columnar vortex. Visualized experimental results utilizing LIF technique are discussed for the purpose of characterization of columnar vortex interacting with a clean and a contaminated free surfaces in the present investigation. The results reveal that surface tension changes due to surface contamination although bulk viscosity remains constant and eventually the behavior of a columnar vortex interacting with a contaminated free surface is totally different from the clean free surface case.

  • PDF

Development and Decay of Columnar Vortex in two faces interface ; gas/liquid and solid/liquid

  • Lee, Seung-Hwan;Kim, Kyung-Hoon;Kim, Seok-Woo
    • Journal of ILASS-Korea
    • /
    • v.6 no.2
    • /
    • pp.29-36
    • /
    • 2001
  • Vortices terminating at free surface have been investigated extensively. however. are focused on surface parallel vortices and little has been known about surface normal vortex or columnar vortex. Visualized experimental results utilizing LlF technique are discussed for the purpose of characterization of columnar vortex interacting with a clean and a contaminated free surfaces and a solid body interface in the present investigation. The results reveal that surface tension changes due to surface contamination although bulk viscosity remains constant and eventually the behavior of a columnar vortex interacting with a contaminated free surface and a solid body interface are totally different from the clean free surface case.

  • PDF

A Study on the Characteristics of Wire-Cut Electrical Discharge Machining for STD-11 Alloy Steel and P-20 Tungsten Carbide Alloy (STD-11 합금공구강과 P-20 초경합금재의 WEDM 특성에 관한 연구)

  • Lee, Jae-Myeong;Heo, Seoung-Jung;Kim, Won-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.1
    • /
    • pp.22-28
    • /
    • 1996
  • From the experimental study of Wire-Cut Electric Discharge Machining of STD-11 alloy steel and P-20 tungsten carbide, the characteristics such as hand drum form and discharge gap have been observed and evaluated for various conditions. Hand drum form can be improved when gap have been observed and evaluated for various conditions. Hand drum form can be improved when gap voltage and spark cycle become smaller, thickness become thinner, wire tension become larger and the no of cutting increases. When 60mm thickness tungsten carbide is cut in normal condition, hand drum form becomes larger due to the low conductivity machining allowance become slightly larger when peak discharge current and gap voltage become larger, or wire tension becomes smaller. Under the same condition, machining allowance of tungsten carbide is larger than alloyed steel by 1/100mm.

  • PDF