• Title/Summary/Keyword: Normal phase HPLC

Search Result 64, Processing Time 0.029 seconds

Liquid Chromatographic Enantiomer Separation of α-Amino Acid Esters as Nitrobenzoxadiazole Derivatives Using Polysaccharide-Derived Chiral Stationary Phases

  • Islam, Md. Fokhrul;Lee, Wonjae
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.111-116
    • /
    • 2015
  • Liquid chromatographic enantiomer separation of ${\alpha}$-amino acid esters as nitrobenzoxadiazole (NBD) derivatives was performed using several chiral stationary phases (CSPs) based on polysaccharide derivatives under fluorescence detection. For enantiomer separation by normal HPLC, the non-aqueous derivatization method of ${\alpha}$-amino acid esters for NBD analytes was introduced. Among the six CSPs used in this study, the performance of Chiralpak IA was superior for enantiomer resolution of NBD derivatives of several ${\alpha}$-amino acid methyl esters. Also the convenient analytical method using polysaccharide-derived CSPs developed in this study was applied to determine the optical purity of ${\alpha}$-amino acids esters. It was investigated that the enantiomeric impurity levels of 0.02-1.73% were found after determination of enantiomeric purities of several commercially available L-amino acid methyl esters. It is expected to be quite useful for enantiomer separation of other ${\alpha}$-amino acid esters as NBD derivatives by normal HPLC.

Efficient Isolation of Dihydrophaseic acid 3'-O-β-D-Glucopyranoside from Nelumbo nucifera Seeds Using High-performance Countercurrent Chromatography and Reverse-phased High-performance Liquid Chromatography

  • Rho, Taewoong;Yoon, Kee Dong
    • Natural Product Sciences
    • /
    • v.24 no.4
    • /
    • pp.288-292
    • /
    • 2018
  • High-performance countercurrent chromatography (HPCCC) coupled with reversed-phase highperformance liquid chromatography (RP-HPLC) method was developed to isolate dihydrophaseic acid 3'-O-${\beta}$-D-glucopyranoside (DHPAG) from the extract of Nelumbo nucifera seeds. Enriched DHPAG sample (2.3 g) was separated by HPCCC using ethyl acetate/n-butanol/water system (6:4:10, v/v/v, normal-phase mode, flow rate: 4.0 mL/min) to give 23.1 mg of DHPAG with purity of 88.7%. Further preparative RP-HPLC experiment gave pure DHPAG (16.3 mg, purity > 98%). The current study demonstrates that utilization of CCC method maximizes the isolation efficiency compared with that of solid-based conventional column chromatography.

Evaluation on the Safety of ${\gamma}$-Irradiated Angelica gigas Nakai: Stability of Active Components and Safety in Genotoxicity Test (감마선 조사 당귀(Angelica gigas Nakai)의 유효성분 안정성 및 유전독성학적 안전성 연구)

  • 조성기;유영법
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.2
    • /
    • pp.300-306
    • /
    • 2000
  • In the present studies, we assessed the stability of active components and toxicological safety of irradiated Angelica gigas Nakai(Danggui). In order to confirm the stability of active components in the ${\gamma}$-irradiated roots of Danggui, the quantitative analysis of decursin and decursinol angelate of ${\gamma}$-irradiated sample was carried out by high performance liquid chromatographic (HPLC) methods using reverse phase columns and normal phase columns. From the root of Danggui, decursin and decursinol angelate were isolated by a silica gel column chromatography(toluene : ether (1 : 1), Hexane : EtOAc(15 : 1)). And then the structures were confirmed in the 1H and 13C-NMR analysis. The HPLC chromatograms of decursin and decursinol angelate in ${\gamma}$-irradiated Danggui were similar with those of non-irradiated sample. In the examination of in vitro genotoxicity of the water extract from ${\gamma}$-irradiated Danggui using Salmonella reversion assay(Ames test) and micronucleus test in Chinese hamster ovary (CHO) cells, mutagenicity was not exhibited in the two assays with or without metabolic activation. These resutls suggest that active components in the ${\gamma}$-irradiated Danggui should be stable and that the safety of ${\gamma}$-irradiated Danggui could be revealed in further test in vivo.

  • PDF

New Efficient Method for Isolation and Purification of Ginsenosides (Ginsenoside의 새로운 분리.정제 방법)

  • 김세원;황석연
    • Journal of Ginseng Research
    • /
    • v.22 no.4
    • /
    • pp.284-288
    • /
    • 1998
  • This study was carried out to establish a new efficient method for isolation and purification of ginsenosides. Silica gel column chromatography, having been used for the isolation of ginsenosides, is advantageous to obtain a large amount of ginsenosides. However, it has a disadvantage to isolate ginsenosides to their highest purity. In addition, normal-or reverse-phase HPLC method thus far reported is confined to quantitative analysis. Especially, it has not been possible to isolate racemic 20(S)- and 20(R)-ginsenoside Rg2. In this experiment, isolation and purification of ginsenosides were accomplished by Diaion HP-20 adsorption chromatography, silica gel column chromatography, recrystalization and Prep. HPLC with or without Prep. TLC. From this study, we could establish a new efficient method for isolation and purification of 9 major and/or minor ginsenosides.

  • PDF

The Use of the Online Two-dimensional Liquid Chromatography Coupled with a Universal Detector for the Screening of Non-volatile Potential Migrants in Food Packaging Materials (식품포장재내 비휘발성 잠재 이행물질들의 스크리닝을 위한 이차원크로마토 그래피와 범용검출기의 이용)

  • Yoon, Chan-Suk;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.16 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • For screening test of the non-volatile compounds which migrate from food packaging materials into foodstuffs, the traditional high performance liquid chromatography (HPLC) systems suffer from the lack of universal detector with high sensitivity and universality and high efficiency HPLC separation column which provides complete separation of complex mixtures into all individual substances. In this work, the use possibility of online two-dimensional liquid chromatography (2D-LC) system coupled with a charged aerosol detector (CAD), a universal detector, was reviewed. 2D-LC system permits to improve peak capacity and resolving power for complex mixtures. Charged aerosol detector (CAD) offers a new feasibility for detection of any non-volatile compounds with high sensitivity and constant response factor in a calibration range. The combination of size exclusion chromatography (SEC) and normal phase HPLC (NP-HPLC) is most frequently used for the separation of the natural and synthetic polymers which are mainly used as raw materials for the manufacture of food packaging materials. However, there is no commercial software available for data acquisition and handling and therefore the quantification in 2D-LC analysis is still rare.

  • PDF

Analysis of Mono-, Di- and Tri-glycerides by high-performance liquid chromatography (HPLC) with evaporative light scattering detection (ELSD) (HPLC/ELSD에 의한 Mono-, Di- 및 Tri-glycerides류 분석)

  • Lee, Man-Ho;Park, Heai-Ku;Kim, In-Whan
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.189-193
    • /
    • 2006
  • Chromatographic separation of glycerol monostearate, glycerol distearate and glycerol tristearate (GMS, GDS, and GTS) has been performed by normal phase HPLC method utilizing a Zorbax silica ($250{\times}4.6mm$, $5{\mu}m$) column and hexane-hexane, IPA and ethyl acetate mixtures as the eluent within 20 min. The observed reproducibility was less than 5% RSD, Suggesting that ELSD was an effective tool for detection of the glycerol stearates of low volatility without chromophore. The detection limits were in the concentration range of 0.3~2 mg/L, and the calibration curves (the log-log plots) were linear in the range of 4~1000 mg/L (with the slopes of 1.06~1.32). The application of the analytical procedure without pretreatment demonstrated that the proposed chromatographic method would be practical for a routine analysis of commercial products.

Development and Validation of a Unique HPLC-ELSD Method for Analysis of 1-Deoxynojirimycin Derived from Silkworms (누에에 함유된 1-Deoxynojirimycin의 분석을 위한 HPLC-ELSD 분석법 밸리데이션)

  • Hyejin Cho;Sullim Lee;Myoung-Sook Shin;Joohwan Lee;Sanghyun Lee
    • Korean Journal of Pharmacognosy
    • /
    • v.54 no.1
    • /
    • pp.38-43
    • /
    • 2023
  • A simple and accurate assay was developed for the quantitative analysis of 1-deoxynojirimycin (1-DNJ) derived from the silkworm (Bombyx mori). Normal-phase high-performance liquid chromatography coupled with an evaporative light scattering detector (HPLC-ELSD) and a hydrophilic interaction liquid chromatography column was used. Various parameters were applied to optimize the analysis method. The limits of detection and quantification of 1-DNJ were 2.97 × 10-3 and 9.00 × 10-3 mg/mL, respectively. The calibration curve showed good linearity results. The concentration range and the r2 value were 0.0625-1.0 mg/mL and 0.9997, respectively. The accuracy test demonstrated a significantly high recovery rate (89.95-103.22%). The relative standard deviation was ≤ 1.00%. Thus, a method for the accurate identification and quantitative analysis of 1-DNJ in silkworms was developed. Moreover, in this procedure, the process of derivatization of 1-DNJ, which was required in previous experiments, could be eliminated. This technique may be actively utilized for the development of pharmaceuticals and health functional foods using 1-DNJ.

Simultaneous Determination of Catecholamines, Serotonin and Their Metabolites in the Biological Sample Using HPLC/ECD (생체 시료 중 카테콜 아민류, 세로토닌 및 대사물질들의 HPLC/ECD 동시 정량분석)

  • Min, Ji-Hyun;Hahn, Young-Hee
    • YAKHAK HOEJI
    • /
    • v.55 no.4
    • /
    • pp.277-283
    • /
    • 2011
  • Simultaneous monitoring of catecholamines and serotonin with their appropriate extraction from the biological samples is required in order to understand thoroughly the regulation of the central and peripheral nervous system. In the present research the segmented gradient elution with the solid phase extraction using a C18 cartridge rather than the previous isocratic elution with alumina extraction is successfully employed to determine norepinephrine (NE), epinephrine (E), dopamine (DA), serotonin (5HT), 3,4-dihydroxyphenylacetic acid (DOPAC) and 5-hydroxyindoleacetic acid (5HIAA) simultaneously within 20 minutes using 3,4-dihydroxyhydrocinnamic aicd as the internal standard (IS). Linearities were obtained in the concentration range between $5{\times}10^{-6}M$ and $1{\times}10^{-4}M$ for all 7 compounds with detection limits of 0.6~1.9 ${\mu}M$. The present HPLC/ECD method yielded reasonable accuracy (relative error; -1.4~1.1%) and precision (relative standard deviation; 0.4~1.9%) for 9 measurements of the standard solution consisting of NE, E, DA, 5HT, DOPAC and 5HIAA compounds. Recoveries of catecholamines, serotonin and their metabolites from human serum were in the range of 57%~86%. While the concentrations of NE and 5HT in the serum of normal Sprague-Dawley rat were found as $1.4{\times}10^{-6}M$ and $2.6{\times}10^{-6}M$, respectively, the contents of NE and 5HT in the serum of the stressed rat were increased 5.6 times and 1.4 times more, respectively.

Column cleaning, regeneration and storage of silica-based columns (실리카 기반 컬럼의 세척, 재생 및 보관 가이드)

  • Matt James;Mark Fever
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.1.1-1.4
    • /
    • 2024
  • This article provides comprehensive guidance on the maintenance, cleaning, regeneration, and storage of silica-based HPLC (High-Performance Liquid Chromatography) columns. The general considerations emphasize the importance of using in-line filters and guard cartridges to protect columns from blockage and irreversible sample adsorption. While these measures help, contamination by strongly adsorbed sample components can still occur over time, leading to an increase in back pressure, loss of efficiency, and other issues. To maximize column lifetime, especially with UHPLC (Ultra-High Performance Liquid Chromatography) columns, it is advisable to use ultra-pure solvents, freshly prepared aqueous mobile phases, and to filter all samples, standards, and mobile phases. Additionally, an in-line filter system and sample clean-up on dirty samples are recommended. However, in cases of irreversible compound adsorption or column voiding, regeneration may not be possible. The document also provides specific recommendations for column cleaning procedures, including the flushing procedures for various types of columns such as reversed phase, unbonded silica, bonded normal phase, anion exchange, cation exchange, and size exclusion columns for proteins. The flushing procedures involve using specific solvents in a series to clean and regenerate the columns. It is emphasized that the flow rate during flushing should not exceed the specified limit for the particular column, and the last solvent used should be compatible with the mobile phase. Furthermore, the article outlines the storage conditions for silica based HPLC columns, highlighting the impact of storage conditions on the column's lifetime. It is recommended to flush all buffers, salts, and ion-pairing reagents from the column before storage. The storage solvent should ideally match the one used in the initial column test chromatogram provided by the manufacturer, and column end plugs should be fitted to prevent solvent evaporation and drying out of the packing bed.

  • PDF

HPLC Analysis and Pharmacokinetics of KAL-1120, a Novel Anti-inflammation Agent, in Rats (흰쥐에서 항염증제 후보물질 KAL-1120의 HPLC 분석 및 약물동태)

  • Shin, Dae-Hwan;Lee, Jung-Yeol;Park, Seong-Hyeok;Lee, Gyeong-Bok;Han, Kun;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.101-107
    • /
    • 2010
  • A rapid and sensitive reversed-phase high performance liquid chromatography (HPLC) method was developed for the determination of N-(-4-Chlorophenyl)-6-hydroxy-7-methoxy-2-chromanecarboxamide (KAL-1120), a novel anti-inflammation agent, in the rat plasma. The method was applied to analyze the compound in the biological fluids such as bile, urine and tissue homogenates. After liquid-liquid extraction, the compound was analyzed on an HPLC system with ultraviolet detection at 275 nm. HPLC was carried out using reversed-phase isocratic elution with a $C_{18}$ column, a mobile phase of a mixture of acetonitril (40 v/v%) at a flow rate of 1.0 mL/min. The chromatograms showed good resolution and sensitivity and no interference of plasma. The calibration curve for the drug in plasma was linear over the concentration range of 0.05-50 ${\mu}g$/mL. The intra- and inter-day assay accuracies of this method ranged from 0.06% to 9.33% of normal values and the precision did not exceed 6.28% of relative standard deviation. The plasma concentration of KAL-1120 decreased to below the quantifiable limit at 1.5 hr after the i.v. bolus administration of 2-10 mg/kg to rats ($t_{1/2,({\alpha})}$ and $t_{1/2,({\beta})$ of 2.15 and 26.7 min at a dose of 2 mg/kg, 3.91 and 33.0 min at a dose of 10 mg/kg, respectively). The steady-state volume of distribution ($V_{dss}$) and the total body clearance ($CL_t$) were not significantly altered in rats given doses from 2 to 10 mg/kg. Of the various tissues tested, KAL-1120 was mainly distributed in the lung and heart after i.v. bolus administration. KAL-1120 was detected in the bile by 30 min after its i.v. bolus administration. However, the concentration in the urine after i.v. bolus administration became too low to measure, suggesting that KAL-1120 is mostly excreted in the bile. In conclusion, this analytical method was suitable for the preclinical pharmacokinetic studies of KAL-1120 in rats.