• Title/Summary/Keyword: Normal operation

Search Result 2,146, Processing Time 0.032 seconds

A clinical study on the changes of serum enzymes after open heart operation under the cardiopulmonary bypases (개심술후 혈청효소 변화에 관한 연구)

  • 장동철
    • Journal of Chest Surgery
    • /
    • v.19 no.2
    • /
    • pp.181-187
    • /
    • 1986
  • The changes of serum creatine phosphokinase [CPK], serum lactic dehydrogenase [LDH], serum glutamic oxaloacetic transaminase [GOT] and serum glutamic pyruvic transaminase [GPT] were studied in a total of 82 cases who underwent open heart operation under the cardiopulmonary bypass at the Department of Thoracic and Cardiovascular Surgery, Chungnam National University Hospital. The results were as follows 1. The average values of CPK and COT after the operation were reached to the maximal values on the first postoperative day, which were returned to the normal range until the fifth postoperative day. The average values of LDH and CPT after the operation were reached to the maximal values on the first and second postoperative day respectively, which were significantly increased until the seventh postoperative day. 2. In the relationship of the serum enzymes and duration of the extracorporeal circulation, the values on the group over 90 minute of the extracorporeal circulation were more increased than on the group below 90 minute of the extracorporeal circulation. 3. In the relationship of the changes of the serum enzymes and congenital heart diseases and acquired heart diseases, there were no significantly differences in the values between the two groups.

  • PDF

관상정맥동 천정결손증 3례 보고

  • 임창영;김요한;이인성;김광택;김형묵
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.218-222
    • /
    • 1987
  • Unroofed coronary sinus syndrome is an uncommon anomaly, Unroofed coronary sinus syndrome is caused by incomplete formation of the left atriovenous fold, and it usually is associated with Left SVC. If it is not diagnosed, a residual reversed or bidirectional shunt will result, and its complications will reduce life expectancy. We experienced 3 cases of unroofed coronary sinus syndrome which combines TOF with PLSVC, partial ECD, primum type ASD. In case of Unroofed coronary sinus syndrome which combines TIF with PLSVC, preoperative diagnosis was not made. In corrective operation for TOF of this case, pump weaning was failed due to hypoxia and cardiac arrest, and he expired at operation room. At autopsy of this case, complete unroofed coronary sinus was found. In the other 2 cases, partial unroofed coronary sinus syndrome was found in operation field and corrective operation was performed successfully. We report these 3 experiences with its review. ^u ++ Noninvasive Assessment of Pressure Gradients across Prosthetic Heart Valve by Doppler Ultrasound - A comparative study of the Duromedics Bileaflet Valves in mitral position and Normal Mitral Valves -with its review.

  • PDF

A Study on Turbine Control and Turbine Bypass Control during Startup of Thermal Power Plants (화력발전소 기동시 터빈 바이패스 시스템과 터빈 제어에 관한 고찰)

  • Choi, In-Kyu;Park, Doo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1664_1665
    • /
    • 2009
  • Many years ago, most of thermal power plants built in this country were of subcritical pressure, of medium or small size, of constant pressure operations and of drum type steam generators with circulation type boilers. But, nowadays almost all of them were of high efficiency, of supercritical pressure, of big capacity, of sliding pressure operations, and of once through type steam generator. It has such advantage as the reduction of startup duration, but it control system and operation method are very complicated. It has a big difference in operation method of turbine and boiler. The feedforward control needs to be introduced to prevent such problems as thermal shock during the transit from normal operation into bypass operation. This paper introduces the turbine control and turbine bypass control during startup of thermal power plants.

  • PDF

A Research on Optimization of Lead-lag Controller Setpoint for Rod control system to prevent fluctuation for NPP (원전 제어봉제어계통 순시변동을 방지하기위한 지상-지연회로 설정치 최적화 연구)

  • Yoon, Duk-Joo;Lee, Jae-Yong;Kim, In-Hwan;Kim, Joo-Sung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1149-1154
    • /
    • 2007
  • Fluctuation of control rod was experienced when plant was operating in normal operation mode in WH type NPPs. In order to cope with increased control rod fluctuation, the lead-lag controller setpoint for rod control system was optimized and resulted in increasing the margin of operation and minimizing unnecessary control rod movement. By optimization of the time constant, the margin of operation was increased by $1.5^{\circ}F$ and the control rod movement was not occurred due to mitigation of temperature fluctuation in loop. According to the mitigation of time constant, the margin of operation was increased but safety margin can be affected badly, so that the influences to FSAR design reference was evaluated. As the result of this evaluation, it satisfied the design reference of the existing safety analysis and was applied to NPP after obtaining the approval.

  • PDF

A study on the Optimal Operation of Distirbution System Using the Modified Block Model Method (수정블럭 모델 법에 의한 배전계통의 최적운용에 관한 연구)

  • 송길영;홍상은;김재영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.4
    • /
    • pp.231-239
    • /
    • 1987
  • Distribution system is one of large and complicated sytem, consisted of a great number of components. Therefore efficient operation based on precise analysis and computation methods is indispensable accommodating growing loads. This paper describes an optimal operation problem to relieve overload flow in radial distribution systems by using modified block model. The problem is formulated as a network problem of synthesizing the optimal spanning tree in a graph, branch and bound method is used for the optimization. Especially modified block model proposed in this paper is validated more practical than conventional model. These methods can be applied to two types of distribution system problems such as, 1) planning problem to check the capability of relieving overload at normal rating, 2) emergency operation problem to determine switching scheme for minimizing customer loads affected by a fault. Examples of application to these problems are discussed.

  • PDF

The Study of Grid Fault Detection for Sag, Swell (Sag와 Swell에 따른 계통 이상 검출에 관한 연구)

  • Kim, Min-Gi;Noh, Yong-Su;Kim, Jun-Gu;Jung, Yong-Chae;Won, Chun-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.471-472
    • /
    • 2013
  • When ESS(Energy Storage System) is under normal operation, island situation can be occur because of grid accidents. When island operation occur, the system mode switches in to UPS(Uninterruptible Power Supply) mode to supply stabled load power. To decide island operation, checking grid magnitude or frequency is general. But regulation for sag and swell is required. In this paper, it proposes grid connection error detection algorithm for UPS operation when sag and swell occurs in grid, and analyzed by simulation.

  • PDF

Knowledge Representation for the Automatic Shutdown System in Boiler Plants (보일러 플랜트의 자동 Shutdown 시스템을 위한 지식표현)

  • 송한영;황규석
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.3
    • /
    • pp.143-153
    • /
    • 1996
  • Shutdown of boiler plants is a dynamic, complicated, and hazardous operation. Operational error is a major contributor to danserous situations during boiler plant shutdowns. It is important to develop an automatic system which synthesizes operating procedures to safely go from normal operation to complete shutdown. Knowledge representation for automatic shutdown of boiler plants makes use of the hierarchical, rule-based framework for heuristic knowledge, the semantic network, frame for process topology, and AI techniques such as rule matching, forward chaining, backward chaining, and searching. This knowledge representation and modeling account for the operational states, primitive operation devices, effects of their application, and planning methodology. Also, this is designed to automatically formulate subgoals, search for positive operation devices, formulate constraints, and synthesize shutdown procedures in boiler plants.

  • PDF

Development of Control Logic for Operation of Fan Stall Warning Equipment Used in Coal-Thermal Power Plant (석탄 화력발전소 송풍기 맥동감시장치 운전을 위한 제어로직 개발)

  • Roh, Yong-Gi;Cho, Hyun-Seob;Jang, Seong-Whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.837-846
    • /
    • 2006
  • In this paper, axial flow fans which applied at coal-thermal power plant(500[MW]) cause a unique phenomenon called 'Stall' under normal operation and this causes abnormal operation and damages the blades. In order to prevent these abnormal operation, this study estimates the reliability of new system which is applying control logic on each parameter with existing black-box-type by field test.

  • PDF

Analytical Study on the Optimal Operating Control of A Hybrid Geothermal Plant (지열복합 열원가기 최적운전채어에 관한 해석적 연구)

  • Jeon, Jong-Ug;Park, Jong-Sam;Myung, Woo-Ho;Kim, Young-Ki;Kim, Yong-Chan
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.2
    • /
    • pp.1-7
    • /
    • 2010
  • The objective of this study is to find the optimal control algorithm of a hybrid Plant, which is combined by renewable energy plant of the GSHP(Geothermal Source Heat Pump) and the normal plant (Chiller, boiler). The work presented in this study was carried out in the EnergyPlus(Version 2.0). The EnergyPlus was modified in order to simulate the hybrid plant. The plant system was controlled by the load-range-based operation in which schemes select a user specified set of equipment for each user specified range of a particular simulation condition. In the use of the load-range-based operation, four kind of control cases were defined and simulated in order to obtain the optimal control algorithm of the hybrid plant. The result showed that the Case 2 was the optimal control algorithm which used the GSHP as a base operating plant and the normal plant as an assistant operating plant. Even though the normal plant was operated in full load and the renewable energy plant of the GSHP was operated in partial load, the annual energy consumption of the normal plant was larger than that of the GSHP plant.

Effect of Ovariectomy and Calcium Intake on Femur and Lumbar Compositions and Bone Related Factors in Adult Rats (성숙한 쥐의 대퇴골과 요추의 조성과 골격관련 인자에 대한 난소절제와 칼슘섭취 효과)

  • 이연숙;김은미
    • Journal of Nutrition and Health
    • /
    • v.34 no.5
    • /
    • pp.532-540
    • /
    • 2001
  • This study explored the effect of calcium levels and/or ovariectomy on bone composition and its related factors using the female Sprague-Dawley rats which achieved peak bone mass in normal(0.5%) calcium intake during growth period. The rats were randomly divided into six groups and fed 0.1%, 0.5% and 1.5% calcium diets for 8 weeks after ovariectomized and sham operation. The results indicated that body weight gain was higher in ovariectomized groups than sham groups, regardless of dietary calcium levels and food intakes. Serum Ca and P concentrations were normal level regardless of dietary calcium levels and operation. Estrogen concentration was decreased in ovariectomized rat groups. Serum alkaline phosphatase activity and urinary hydroxyproline were increased in ovariectomized groups. When rats were fed normal Ca diet during growing period, weight, length and breaking force of femur were not significantly different in all groups but increased the same level. Generally, lipid contents in lumbar and femur were lower in low calcium groups and this effect was more pronounced in femur. In case of femur, the significant decrease in Ca contents of bone was observed in a relatively short period of feeding low Ca diet, even though it appeared th desirable peak bone mass had achieved through the growing period by supplementing the adequate amount of calcium. The marked decrease of estrogen levels after ovariectomy did not seem to influence greatly bone parameters measured except bone wet weight. Therefore, this study indicated that lower intake of Ca might be more important determinating factor against osteoporosis than postmenopausal state stimulated by ovariectomy in female rats. With normal or high intake of Ca it appears possible to prevent bone loss in postmenopausal period, and this might apply only in case of achieving peak bone mass in the growing with the adequate intake of calcium. (Korean J Nutrition 34(5) : 532∼540, 2001)

  • PDF