• 제목/요약/키워드: Normal form

검색결과 1,536건 처리시간 0.033초

Reliability of underground concrete barriers against normal missile impact

  • Siddiqui, N.A.;Khan, F.H.;Umar, A.
    • Computers and Concrete
    • /
    • 제6권1호
    • /
    • pp.79-93
    • /
    • 2009
  • In the present paper, a methodology has been presented for the reliability assessment of concrete barriers that lie at a certain depth in the soil, and a missile (a rigid projectile) impacts the top of the soil cover normally, and subsequently after penetrating the soil cover completely it hits the barrier with certain striking velocity. For this purpose, using expressions available in the literature, striking velocity of missile at any depth of soil has been derived and then expressions for the depths of penetration in crater and tunnel region of concrete barrier have been deduced. These depths of penetration have been employed for the derivation of limit state functions. Using the derived limit state functions reliability assessment of underground concrete barrier has then been carried out through First Order Reliability Method (FORM). To study the influence of various random variables on barrier reliability, sensitivity analysis has also been carried out. In addition, a number of parametric studies is conducted to obtain the results of practical interest.

Effects of antitumor polysaccharides from albizza julibrissin on immune function

  • Moon, Chang-Kiu;Lee, Byeong-Gon;Lee, Soo-Hwan;Kang, Tak-Lim
    • Archives of Pharmacal Research
    • /
    • 제8권4호
    • /
    • pp.277-282
    • /
    • 1985
  • Polysaccharide fractions were prepared from Albizzia julibrissin by different extraction schedules. The fractions obtained were designated as PS-I and PS-II, respectively. Further purification of PS-I by Sephadex G-200 column chromatography gave two subfractions, Alju A and alju B, Each fraction showed marked antitumor activity against sarcoma 180 solid form but not ascite form. PS-I and PS-II increased delayed hypersensitivity in normal and tumor bearing mice. PS-I treatment led to moderate restoration of the suppressed antibody production in tumor bearing mice.

  • PDF

Sensitivity-based reliability analysis of earth slopes using finite element method

  • Ji, Jian;Liao, Hong-Jian
    • Geomechanics and Engineering
    • /
    • 제6권6호
    • /
    • pp.545-560
    • /
    • 2014
  • For slope stability analysis, an alternative to the classical limit equilibrium method (LEM) of slices is the shear strength reduction method (SRM), which can be integrated into finite element analysis or finite difference analysis. Recently, probabilistic analysis of earth slopes has been very attractive because it is capable to take the soil uncertainty into account. However, the SRM is less commonly extended to probabilistic framework compared to a variety of probabilistic LEM analysis of earth slopes. To overcome some limitations that hinder the development of probabilistic SRM stability analysis, a new procedure based on recursive algorithm FORM with sensitivity analysis in the space of original variables is proposed. It can be used to deal with correlated non-normal variables subjected to implicit limit state surface. Using the proposed approach, a probabilistic finite element analysis of the stability of an existing earth dam is carried out in this paper.

Reliability analysis on fatigue Strength for Certification of Aircraft Composite Structures

  • Choi, Cheong Ho;Lee, Doo Jin;Jo, Jae Hyun;Bae, Sung Hwan;Lee, Myung Jik;Lee, Jong Ho
    • 항공우주시스템공학회지
    • /
    • 제15권2호
    • /
    • pp.16-25
    • /
    • 2021
  • Reliability of fatigue strength on Aircraft Composites(GFRP) Structures was assessed in this paper. Fatigue strength of GFRP was used through the existing fatigue test data with Monte Carlo method. The Sa-Nf curve of composites fatigue strength was assumed as normal distribution and reliability was analyzed using SSIT model. Fatigue stress was designed IAW ASTM F3114-15 with special safety factor of Ssf=1.2~2.0. Reliability was calculated by analytic method and FORM. Sensitivity for the effect of mean and standard deviation of fatigue strength as well as fatigue stability was evaluated. This result can be usefully applied to reliability and fatigue design for composite structures of light weight aircraft.

Calculation of X-ray attenuation coefficients for normal and cancerous breast tissues

  • Aysun Boke
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.241-246
    • /
    • 2024
  • The study was carried out by numerical integration based on the diffraction properties and elemental composition. The elemental compositions of breast tissues in the literature were tested. The photon attenuation coefficients calculated using the recent elemental composition were found within 0.2-16% for adipose tissue and within 0.04-17% for glandular tissue with the experimental reference data. The attenuation coefficients of cancerous breast tissue calculated according to the elemental content previously measured in breast cancer patients were found within 0-17% with experimental data in the literature. The attenuation coefficients are of great interest to medical research. To calculate realistic attenuation coefficients, the characteristic coherent scatter, which is most intense at small angles, must be considered. For this reason, experimentally measured form factor data were reviewed, and the most compatible one with the theoretical form factor data produced in this study was used at low momentum transfer x (0 < x ≤ 8 nm-1). The differential linear coherent scattering distributions were calculated for an energy value of 17.44 keV and compared with their experimental counterparts.

Elastic Wave Propagation in Monoclinic System Due to Harmonic Line Load

  • Kim, Yong-Yun
    • The Journal of the Acoustical Society of Korea
    • /
    • 제17권2E호
    • /
    • pp.47-52
    • /
    • 1998
  • An analysis of dynamic responses is carried out on monoclinic anisotropic system due to a buried harmonic line source. The load is in the form of a normal stress acting along an arbitrary axis on the plane of symmetry within the orthotropic materials: In case that the line load is acting along the symmetry axis normal to the plane of symmetry, plane wave equation is coupled with verital shear wave and longitudinal wave. However, if the line load is acting along an arbitrary axis normal to the plane of symmetry, plane wave equation is coupled with vertical shear wave, longitudinal wave and horizontal shear wave. We first considered the equation of motion in a reference coordinate system, where the line load is coincident with a symmetry axis of the orthotropic material. Then the equation of motion is transformed into one with respect to general coordinate system with azimuthal angle by using transformation tensor. Plane wave solutions of monoclinic systems are derived for infinite media. Finally complete solutions for the plane harmonic wave are obtained by calculating the inverse of the integral transforms, in which bulk wave poles are avoided by deforming the contour of the integration to the complex plane. Numerical results for examples of orthotropic material belonging to monoclinic symmetry are demonstrated.

  • PDF

헤드와의 접촉에 의한 오버코팅층을 포함한 하드 디스크의 응력 해석 (Stress Analysis of the Hard Disk with Overcoating Layer under the Contact with Head)

  • 이강용;양지혁
    • 대한기계학회논문집A
    • /
    • 제24권4호
    • /
    • pp.946-954
    • /
    • 2000
  • The purposes of the paper are to calculate stresses and strains of the disk with overcoating layer rotating quickly under normal loading and shear loading by contacting with head and to present material properties preventing the delamination between the disk and overcoating layer. The hard disk is modeled as two-layered disk composed with overcoating layer and the rest layers and the loading onto the disk is assumed axisymmetric. Solutions to equilibrium equations and compatibility equations are derived with the form of polynimial and Bessel function and coefficients satisfying boundary conditions are obtained differently for the case of body force, normal force and shear force. The risk of delamination are investigated for us to calculate the differences of strains at the interface between the disk and overcoating layer and the material properties preventing delamination are presented by calculating the differences of strains according to Young's modulus and density of disk.

사람 혈청 트란스페린수용체의 단클론 항체를 이용한 방사면역측정과 철영양상태의 진단 (Immunoradiometric Assay using Monoclonal Antibody Against Human Serum Transferrin Receptor for Diagnosis of Iron Deficiency)

  • 김승렬
    • Journal of Nutrition and Health
    • /
    • 제29권9호
    • /
    • pp.971-980
    • /
    • 1996
  • The soluble transferrin receptor(TfR) in human serum has been shown recently to be a truncated form of intact membrane bound receptor containing most of the extracellular domain. We purfied the transferin-free TfR from human serum by immounoaffinity chromatography which produced the single protein identity in high resolution gel chormatography. The monoclonal antibodies(MAb) against purifed serum TfR were produced by fusion of spleen cells o fimmunized Balb/c mice and SP2 cells. Ten hybrids producing MAb specific for serum TfR were identifed and determine their iostypes. A immunoraddiometric assay (IRMA) for serum TfR was established using two monoclonal IgG1 antibodies as the coating and indicator antibodies on the bosis of their suitability in sandwich IRMA of serum TfR. The mean serum TfR levels in the 15 normal male, 15 normal female, and 19 iron-deficient subjects were 5.4$\pm$0.98, 4.6$\pm$0/76, and 18.0$\pm$12.8mg/1, respectively, and the difference in mean values between normal and iron deficient subjects was significant(p=0.0005). There existed the inverse logarithmic relationship(r=-0.9336, p<0.0001) between the serum TfR and ferritin levels.

  • PDF

Development of Fingertip Tactile Sensor for Detecting Normal Force and Slip

  • Choi, Byung-June;Kang, Sung-Chul;Choi, Hyouk-Ryeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1808-1813
    • /
    • 2005
  • In this paper, we present the finger tip tactile sensor which can detect contact normal force as well as slip. The developed sensor is made of two different materials, such as polyvinylidene fluoride(PVDF) that is known as piezoelectric polymer and pressure variable resistor ink. In order to detect slip to surface of object, a PVDF strip is arranged along the normal direction in the robot finger tip and the thumb tip. The surface electrode of the PVDF strip is fabricated using silk-screening technique with silver paste. Also a thin flexible force sensor is fabricated in the form of a matrix using pressure variable resistor ink in order to sense the static force. The developed tactile sensor is physically flexible and it can be deformed three-dimensionally to any shape so that it can be placed on anywhere on the curved surface. In addition, we developed a tactile sensing system by miniaturizing the charge amplifier, in order to amplify the small signal from the sensor, and the fast signal processing unit. The sensor system is evaluated experimentally and its effectiveness is validated.

  • PDF

과개교합자의 악안면 형태에 관한 두부 X-선사진 계측학적 연구 (ROENTGENOCEPHALOMETRIC STUDY ON CRANIOFACIAL MORPHOLOGY OF DEEPBITES)

  • 김희정;남동석
    • 대한치과교정학회지
    • /
    • 제23권3호
    • /
    • pp.341-358
    • /
    • 1993
  • This study was investigated to evaluate the morphologic characteristics of deepbite tendency as multiple factors. The subjects consisted of 60 control subjects(male 25, female 35) and 137 deephite patients(68 male, 69 female). The deepbite group was composed of 4 subgroups(Class I 44, Class II div. 1 40, Class II div. 2 13, Class III 40). The mean age was 21.57 year for the control group 21 year for deepbite group lateral cephalograph in centric occlusion were taken, traced, and digitized for each subject. The statistically computerized analysis was carried out with SAS program. The results were as follows ; 1. In deepbite group, saddle angle is lesser than that of normal group. 2. The vertical dysplasia is prominent on anterior lower face and is closely related with mandibular form and inclination. 3. Without consideration of sagittal relationship, the dental factors such as curve of Spee, interincisal angle, U1 to upper lip length were prominent in the deepbite group. 4. Although there were individual variances in the perioral soft tissue profile, the lip presented more protruded pattern. 5. There was no significant difference in hyoid bone position and inclination between normal and deepbite group. 6. The multivariate discriminant analysis between normal and Class I deepbite group showed that curve of Spee, AB-MP angle, interincisal angle, articular agnle were critical in the determination of deepbite as multiple factors.

  • PDF