• Title/Summary/Keyword: Normal Dispersion

Search Result 147, Processing Time 0.03 seconds

Electro-optic Characteristics of the fringe-field Driven-reflective Liquid Crystal Display with One Polarizer (1매의 편광판으로 구성된 반사형 Fringe-field Switching Mode의 전기 광학 특성)

  • 정태봉;박지혁;이종문;김용배;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.2
    • /
    • pp.131-137
    • /
    • 2003
  • We have performed computer simulation to obtain electro-optic chracteristics of reflective liquid crystal display (LCD) using wide viewing angle LC mode, fringe field switching(FFS). Unlike other reflective LCD modes, in the FFS mode, the LC director in plance so an application to reflective display consisted of polarizer, LC layer and reflector is possible. when an incident light is 550mm, the optimal cell retardation value is 0.1365${\mu}$m and the efficiency of reflectivity is high over 90% with very little wavelength dispersion. Further, we have studied a new reflective display with polarizer, optical compensation film with half plate, LC plus reflector. The display with optimized cell parameters shows high contrast ratio (CR) over 130 with high light efficiency over 90% at normal direction and the CR greater than 5 exists over 60$^{\circ}$ of polar angle in all directions.

A Study on Optimum Value of Design Parameter of Multivariate EWMA and CUSUM charts for Monitoring Dispersion Matrix

  • Chang, Duk-Joon
    • Journal of Integrative Natural Science
    • /
    • v.14 no.3
    • /
    • pp.116-122
    • /
    • 2021
  • Properties and comparison of multivariate CUSUM and EWMA charts for monitoring Σ of multivariate normal N(${\underline{\mu}}$, Σ) process has considered. Comparison of the performances of the considered charts, the numerical values are obtained by simulation with 10,000 iteration in terms of ATS, ANSS and ANSW. We found that EWMA chart with small values of smoothing constant more effectively detects the process changes than with large smoothing constant. And we also found that CUSUM chart with small value of reference value is more effectively detecting the process change than with large reference value. If a process engineer has interest in detecting small amount of shift rather than large shift, he/she can be recommended to use small smoothing constant in EWMA chart and small reference value in CUSUM chart.

Biomechanical Analysis of Arch Support Devices on Normal and Low Arch (정상족과 편평족의 Arch Support 사용에 따른 운동역학적 분석)

  • Park, Seung-Bum;Park, Jae-Young;Kim, Kyung-Hun
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.1
    • /
    • pp.91-99
    • /
    • 2010
  • The purpose of this study was to the kinetic variables effects from the use of arch support inserts on low-arched people. We selected 10 people for the research and separated them into 2 groups, 5 people for the normal arched group and 5 people for the low arched group. Each group wear shoes which have a 3 step convertible arch support (level 0, level 2, level 5) and we measured their foot pressure and 3D motion analysis data. As a result, we found that the mean pressure at the heel of the low arched group was decreased when using the arch supports. The arch support induced the correct grounding area for the foot and dispersion of foot pressure. 3D motion analysis found that as the height of the arch support was increased, the movement of the Y-axis(inversion-eversion) was increased to relieve the shock to the heel. The arch support insert limited the range of motion(ROM) of the Z-axis(abduction-adduction) of the low arched person's ankle joint and prevented ankle injury caused by the excessive eversion when walking. Low arched people are seen to be easily tired due to the ineffective shock absorption of the knees and abnormal walking motion. In order to improve the problems, a 3 step convertible arch support(level 5) insert would improve the low-arched people's walking ability. In other words, the low arched people should be expected to walk as well as normal arched people when they wear shoes with the arch support insert.

Does conventional freezing affect sperm DNA fragmentation?

  • Le, Minh Tam;Nguyen, Thai Thanh Thi;Nguyen, Tung Thanh;Nguyen, Trung Van;Nguyen, Tam An Thi;Nguyen, Quoc Huy Vu;Cao, Thanh Ngoc
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.46 no.2
    • /
    • pp.67-75
    • /
    • 2019
  • Objective: Sperm cryopreservation has been widely used in assisted reproductive technology, as it offers great potential for the treatment of some types of male infertility. However, cryopreservation may result in changes in membrane lipid composition and acrosome status, as well as reductions in sperm motility and viability. This study aimed to evaluate sperm DNA fragmentation damage caused by conventional freezing using the sperm chromatin dispersion test. Methods: In total, 120 fresh human semen samples were frozen by conventional methods, using SpermFreeze Solution as a cryoprotectant. Routine semen analysis and a Halosperm test (using the Halosperm kit) were performed on each sample before freezing and after thawing. Semen parameters and sperm DNA fragmentation were compared between these groups. Results: There was a significant decrease in sperm progressive motility, viability, and normal morphology after conventional freezing (32.78%, 79.58%, and 3.87% vs. 16%, 55.99%, and 2.55%, respectively). The sperm head, midpiece, and tail defect rate increased slightly after freezing. Furthermore, the DNA fragmentation index (DFI) was significantly higher after thawing than before freezing (19.21% prior to freezing vs. 22.23% after thawing). Significant increases in the DFI after cryopreservation were observed in samples with both normal and abnormal motility and morphology, as well as in those with normal viability. Conclusion: Conventional freezing seems to damage some sperm parameters, in particular causing a reduction in sperm DNA integrity.

ST-T Changes of Multichannel Magnetocardiographic Pattern in Myocardial Ischemia (허혈에 의한 다채널 심자도의 ST-T 변화)

  • Kwon, H.;Kim, K.;Lee, Y.H.;Kim, J.M.;Lim, H.K.;Park, Y.K.;Chung, N.;Ko, Y.G.;Joung, B.;Kim, J.B.;Cho, J.R.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.35-39
    • /
    • 2007
  • Myocardial ischemia causes heterogeneity of ventricular repolarization and sometimes produces changes of the ST-T wave in ECG. Therefore, morphological changes of ST-T waveform in ECG have a clinical significance in diagnosing myocardial ischemia. In this study, we investigated the ST-T changes caused by myocardial ischemia in magnetocardiography (MCG). We analyzed MCG patterns of biphasic T, ST segment deviations from baseline, main current angle of $T_{peak}$ and $T_{peak}$ dispersion in 300 CAD patients without ST elevation in ECG, 122 symptomatic patients and 48 normal subjects. MCGs were recorded by multichannel SQUID system in a magnetically shielded room. As results, we found that appearances of the abnormality were strongly correlated with the severity of myocardial ischemia. Also we found that the percentage of the patients showing MCG changes were higher than those in ECG. These results show that morphological changes of ST-T waveform in MCG can be used as a marker of myocardial ischemia.

  • PDF

Theoretical Prediction of Dynamic Elastic Moduli and Attenuation Properties of Fiber-Reinforced Composite Materials (섬유강화 복합재료의 동탄성계수 및 감쇠특성의 이론적 예측)

  • 김진연;이정권
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2328-2339
    • /
    • 1992
  • The propagation of coherent time-harmonic elastic L-and SV-waves is studied in a medium with random distribution of cylindrical inclusions. The purpose of the research is to characterize the dynamic elastic moduli and the attenuation properties of fiber-reinforced composite materials. The cylindes representing the fibers are assumed to be distributed in parallel with each other and the direction of incident waves are normal to the cylinder axes. A multiple scattering formula using the single scattering coefficients in conjunction with the Lax's quasicrystalline approximation is derived from which the dispersion relation for such medium is obtained. In order to formulate the multiple scattering interaction between cylinders, the pair correlation functions are generated by the Monte Carlo simulation technique. From the numerically evaluated complex wavenumbers, the propagation speed of the average wave, the coherent attenuation and the effective elastic moduli are presented as functions of frequency and fiber volume fraction.

A Study on the Diffusion of Gaseous Radioactive Effluents Based on the Statistical Method (통계적 방법을 이용한 방사성 물질의 대기 확산 평가)

  • Na, Man-Gyun;Lee, Goung-Jin
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.251-257
    • /
    • 1998
  • A diffusion model of radioactive gaseous effluents is improved to apply for domestic nuclear power plants. Up to now, XOQDOQ computer code package developed by U. S NRC has been used for the assessment of radioactive plume dispersion by normal operation of domestic nuclear power plants. XOQDOQ adopts the straight-line Gaussian plume model which was basically derived for the plane terrain. However, since there are so many mountains in Korea, the several shortcomings of XOQDOQ are improved to consider the complex terrain effects. In this work, wind direction change is considered by modifying the wind rose frequency using meteorological data of the local weather stations. In addition, an effective height correction model, a plume reduction model due to plume penetration into mountain, and a wet deposition model are adopted for more realistic assessments. The proposed methodology is implemented in Yongkwang nuclear power plants, and can be used for other domestic nuclear power plants.

  • PDF

A Study on Comparison between the Propagation of Uncertainty by GUM and Monte-Carlo Simulation (측정 불확도 표현 지침서(GUM)와 Monte-Carlo Simulation에 의한 불확도 전파 결과의 비교 연구)

  • Jungkee Shu;Hyungsik Min;Minsu Park;Jin-Chun Woo;Jongsang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.1
    • /
    • pp.31-37
    • /
    • 2003
  • The expanded uncertainties calculated by the application of GUM -approximation and Monte-Carlo simulation were compared about the model equation of one-point calibration which is widely used for the measurements and chemical analysis. For the comparisons, we assumed a set of artificial data at the various level of concentration and dispersion of t or normal distribution. Mistakes of more then 50 % was revealed at the values calculated by GUM-approximation in comparison with those of Monte-Carlo simulation because of the excess dispersion from t-distribution and non-linearity by division in the equation. In contrary, the mistake of calculation due to non-linearity of the equation was not observed in the level of detection limits with the equation of one-point calibration, because of the relatively large values of uncertainty in response.

Filtration of dispersed nanoparticles using cyclone and ultrasonic atomization (초음파 무화 및 사이클론을 이용한 분산된 나노입자의 여과법)

  • Jung, Jihee;Kim, Moojoon;Kim, Jungsoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.9-15
    • /
    • 2022
  • In order to overcome the limitation of conventional nanoparticle dispersion methods such as sonicator or homogenizer, a filtration method using an ultrasonic atomization effect and cyclones was proposed in this study. A 0.5 wt% suspension was made with Al2O3 powder with an average diameter of 250 nm. The suspension was filtered by the proposed method after pre-dispersing using a sonicator and a homogenizer, respectively. As the result, in the case of the suspension after pre-dispersing with a sonicator, the particle size distribution of the filtered suspension started showing up a single normal distribution indicating the mode of the average diameter only after the 3rd cyclone process. On the other hand, in the case of the suspension with the homogenizer pre-dispersion, similar results appeared from the 2nd cyclone process. Filtration of various types of nanoparticles is expected to be possible by adjusting ultrasonic atomization frequency and manipulating the design of the cyclone.

Using a Stretch Sensor About of Squat Ankle Range of Motion Check Socks -Focusing on Men in Their Late 20s- (스트레치 센서를 이용한 스쿼트 시 발목 가동범위 체크 센서 양말에 관하여 -20대 후반 남성을 중심으로-)

  • Song, Kwanwoo;Park, Jinhee;Kim, Jooyong
    • Journal of Fashion Business
    • /
    • v.26 no.2
    • /
    • pp.129-142
    • /
    • 2022
  • The purpose of this study is to develop socks to check the range of ankle movement during squats for men in their late 20s. Sensors of 6, 8, and 12 mm were selected, and each sample was impregnated 1 to 3 times. It was prepared using a CNT dispersion, and the GF value was measured using UTM. Among them, the sample with 2 impregnation showed the best GF value. As a result of applying each sample to the socks, the 12 mm sensor was wider than the area of the Achilles tendon, resulting in noise, and the 8 mm sensor was higher than the tensile strength of the socks, resulting in a decrease in the graph. Therefore, testing was performed using a 6 mm sensor. In order to determine the effectiveness of the sensor, the normal operating range was checked through squats, and significant changes were confirmed when the operating range was checked again through squats by performing operations that can increase the operating range through Gastrocnemius, Soleus stretching, and low lunge. Using the results of this study, it is expected that the average value of the ankle movement range of the user is checked prevent injury, to be provided as basic data for the production of shoe products and the promotion of physical health.