• Title/Summary/Keyword: Normal

Search Result 40,647, Processing Time 0.064 seconds

On Tightness of Product Space

  • Hong, Seung Hee
    • The Mathematical Education
    • /
    • v.13 no.3
    • /
    • pp.17-18
    • /
    • 1975
  • 거리공간과 Normal countable compact의 위상적이 Normal이라는 것은 A.H. Stone에 의하여 이미 밝혀졌고, V.I. Malyhin은 space expX의 Cardrmal invariant와 공간 X 사이의 관계를 논하였다. 본 논문에서는 V.I. Malyin이 밝힌 tightness의 개념을 도입하여 countable tightness의 pracompact와 normal strongly countable compact 공간의 topological product가 Normal이라는 것을 증명하였다.

  • PDF

MEVVA ion Source And Filtered Thin-Film Deposition System

  • Liu, A.D.;Zhang, H.X.;Zhang, T.H.;Zhang, X.Y.;Wu, X.Y.;Zhang, S.J.;Li, Q.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.2
    • /
    • pp.55-57
    • /
    • 2002
  • Metal-vapor-vacuum-arc ion source is an ideal source for both high current metal ion implanter and high current plasma thin-film deposition systems. It uses the direct evaporation of metal from surface of cathode by vacuum arc to produce a very high flux of ion plasmas. The MEVVA ion source, the high-current metal-ion implanter and high-current magnetic-field-filtered plasma thin-film deposition systems developed in Beijing Normal University are introduced in this paper.

  • PDF

POSTEROANTERIOR CEPHALOMETRIC STUDY OF FACIAL ASYMMETRY ABOUT CLINICAL CHARACTERISTICS AND CHANGES AFTER ORTHOGNATHIC SURGERY (안모비대칭환자의 임상적 특성 및 악교정수술후 변화에 관한 연구;정모두부방사선 규격사진의 계측을 중심으로)

  • Choi, You-Sung;Lee, Sang-Chull
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.3
    • /
    • pp.396-410
    • /
    • 1996
  • This study was carried out to evaluate the distribution and the degree of the asymmetry existed in normal persons and asymmetric patients, and to investigate the changes of asymmetric patients after orthognathic surgery. The analysis was performed with the posteroanterior cephalometric radiography of 60 normal persons and 31 facial asymmetric patients. The results were as follows : 1. The degree of normal asymmetry existed in normal persons was not significant except MF and Me measurements. 2. The degree of normal asymmetry according to sex difference was not significant except cranial base area. 3. When normal persons were compared to asymmetric patients, there were more measurements which presented significant asymmetry on mandible than on maxilla. 4. When postoperative state was compared to preoperative state, the degree of asymmetry were usually decreased except AGO and GA measurements, especially the Cd, MF, Me, and Cd-Me measurements decreased significantly. 5. When postoperative state was compared to normal persons, 4 measurements of mandible approached significantly the measurements of normal persons.

  • PDF

Polynomially Adjusted Normal Approximation to the Null Distribution of Ansari-Bradley Statistic

  • Ha, Hyung-Tae;Yang, Wan-Youn
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.6
    • /
    • pp.1161-1168
    • /
    • 2011
  • The approximation for the distribution functions of nonparametric test statistics is a significant step in statistical inference. A rank sum test for dispersions proposed by Ansari and Bradley (1960), which is widely used to distinguish the variation between two populations, has been considered as one of the most popular nonparametric statistics. In this paper, the statistical tables for the distribution of the nonparametric Ansari-Bradley statistic is produced by use of polynomially adjusted normal approximation as a semi parametric density approximation technique. Polynomial adjustment can significantly improve approximation precision from normal approximation. The normal-polynomial density approximation for Ansari-Bradley statistic under finite sample sizes is utilized to provide the statistical table for various combination of its sample sizes. In order to find the optimal degree of polynomial adjustment of the proposed technique, the sum of squared probability mass function(PMF) difference between the exact distribution and its approximant is measured. It was observed that the approximation utilizing only two more moments of Ansari-Bradley statistic (in addition to the first two moments for normal approximation provide) more accurate approximations for various combinations of parameters. For instance, four degree polynomially adjusted normal approximant is about 117 times more accurate than normal approximation with respect to the sum of the squared PMF difference.

Effect of normal load on the crack propagation from pre-existing joints using Particle Flow Code (PFC)

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming
    • Computers and Concrete
    • /
    • v.19 no.1
    • /
    • pp.99-110
    • /
    • 2017
  • In this paper, the effect of normal load on the failure mechanism of echelon joint has been studied using PFC2D. In the first step, calibration of PFC was undertaken with respect to the data obtained from experimental laboratory tests. Then, six different models consisting various echelon joint were prepared and tested under two low and high normal loads. Furthermore, validation of the simulated models were cross checked with the results of direct shear tests performed on non-persistent jointed physical models. The simulations demonstrated that failure patterns were mostly influenced by normal loading, while the shear strength was linked to failure mechanism. When ligament angle is less than $90^{\circ}$, the stable crack growth length is increased by increasing the normal loading. In this condition, fish eyes failure pattern occur in rock bridge. With higher ligament angles, the rock bridge was broken under high normal loading. Applying higher normal loading increases the number of fracture sets while dilation angle and mean orientations of fracture sets with respect to ligament direction will be decreased.

A COMPARATIVE STUDY ON CRANIOFACIAL SKELETON BETWEEN ANGLE'S CLASS III MALOCCLUSION AND NORMAL OCCLUSION (Angle씨 제III급 부정교합의 두개 및 악안면 경조직에 관한 연구)

  • Park, Sei-Jin;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.17 no.1
    • /
    • pp.63-72
    • /
    • 1987
  • This is to investigate the difference between craniofacial correlation of Angle's class III malocclusion and that of normal occlusion. For this investigation, 28 adult males and famales, who have class III malocclusion, and 35 adult males and 46 adult famals., who have normal occlusion were selected to measure actual dimension of cranial base and to investigate ratio of various parts of maxillofacial skeleton against cranial base. Class III malocclusion were, also , classified based on SNA and SNB angle in normal range. Results were as follows. 1. In class III malocclusion, actual dimension of cranial base were appeared to be less than normal occlusion in both sex. 2. In class III malocclusion, values were less than normal occlusion in BN/ptm-A in both sex, but had no significance between two. 3. In class III malocclusion, ramal inclination, mandible inclination, BN/Go-Pog, lower genial angle were appeared to be greater. Thus, characteristic mandibular protrusive appearance of class III malocclusion was due to relative ratio and morphologic characteristic of mandibular body dimension against cranial base. 4. In class III malocclusion, upper incisors were labially tilted and lower incisors were lingually tilted compared to normal occlusion. 5. In typing of class III malocclusion, the most common type was found to be one which maxillas were in normal range, while mandibles were in protrusive tendency.

  • PDF

Optimization of the fabrication process using nanostructured carbon for low-cost FED application

  • Sun, Z.;Wang, L.L.;Chen, T.;Zhang, Z.J.;Cao, Z.Y.;Chen, Y.W.;Pan, L.K.;Feng, T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.274-277
    • /
    • 2006
  • Nanostructured carbon (nm-C), including carbon nanotubes and nanofibers (CNTs/CNFs) is promising for low-cost field emission display (FED) application. By modification of CNTs/CNFs, uniform CNTs/CNFs can be obtained and used for field emission cathode (FEC) on glass substrate. By screen-printing (SP) and electrophoretic deposition (EPD) process, large area FEC can be obtained. The FED properties are studied and compared. Both SP and EPD FEC show excellent field emission properties, such as low emission field and uniform emission, after optimization the fabrication process. While EPD FEC exhibits better luminescence image. By vacuum sealing, the low cost nm-C-FED prototypes based on EPD cathode have been demonstrated.

  • PDF