• 제목/요약/키워드: Nonlinear switching control

검색결과 185건 처리시간 0.022초

진상각 제어에 따른 AC 서보 모터의 토오크 특성에 관한 연구 (A study on the torque characteristic of AC servo system by phase advance control)

  • 임윤택;손명훈;허욱열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.393-400
    • /
    • 1992
  • The DC(Direct-Current) servo motor has widely used for many application areas, FA(Factory Automation), OA(Office Automation) and home applications. But DC servo motor needs periodical inspection because it has brush and commutator. Recently, AC servo motor has expanded it's application areas due to for the development of the power semi-conductor and control technology. But it has large torque ripple for it's small number of commutation. And it also has cogging torque due to permanent magenet rotor. Therefore it can't run balence rotarion. Many torque ripple reduction methods are published. In this paper, phase advanced method adopted for torque ripple reduction of AC servo motor. In this research, AC servo motor torque characteristic variation surveied under the phase advance control through the computer simulation. Under the simulation, the load inertia varied from 0.0001[Kg.m$^{2}$] to 0.0314[Kg.m$^{2}$]. The result os nonlinear simulation, torque and speed ripple of AC servo motor under the phase advance control reduced approximately 50[%] and 10[%]. And maximum torque of AC servo motor under phase advance control condition increased about 5[%] as compare with fixed switching time.

  • PDF

On the Design of Simple-structured Adaptive Fuzzy Logic Controllers

  • Park, Byung-Jae;Kwak, Seong-Woo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제3권1호
    • /
    • pp.93-99
    • /
    • 2003
  • One of the methods to simplify the design process for a fuzzy logic controller (FLC) is to reduce the number of variables representing the rule antecedent. This in turn decreases the number of control rules, membership functions, and scaling factors. For this purpose, we designed a single-input FLC that uses a sole fuzzy input variable. However, it is still deficient in the capability of adapting some varying operating conditions although it provides a simple method for the design of FLC's. We here design two simple-structured adaptive fuzzy logic controllers (SAFLC's) using the concept of the single-input FLC. Linguistic fuzzy control rules are directly incorporated into the controller by a fuzzy basis function. Thus some parameters of the membership functions characterizing the linguistic terms of the fuzzy control rules can be adjusted by an adaptive law. In our controllers, center values of fuzzy sets are directly adjusted by an adaptive law. Two SAFLC's are designed. One of them uses a Hurwitz error dynamics and the other a switching function of the sliding mode control (SMC). We also prove that 1) their closed-loop systems are globally stable in the sense that all signals involved are bounded and 2) their tracking errors converge to zero asymptotically. We perform computer simulations using a nonlinear plant.

환경변화에 강인한 태양광 발전의 최적전류 MPPT 제어 (Optimal Current Detect MPPT Control of PV System for Robust with Environment Changing)

  • 최정식;고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.47-58
    • /
    • 2011
  • This paper proposes the optimal current detect(OCD) maximum power point tracking(MPPT) control of photovoltaic(PV) system for robust with environment changing. The output characteristics of the solar cell is a nonlinear and affected by a temperature, the solar radiation and temperature. Conventional MPPT control methods are tracked the maximum power point by constant incremental value. So these methods are slow the response speed and generated the vibration in steady state and cannot track the MPP in environment condition changing. And power loss is generated because of the self-excitation vibration in MPP region. To solve this problem, this paper proposes the novel control algorithm. Proposed algorithm is detected the optimal current in two control region using the output power and current curve. Detected current is used the converter switching for tracking the MPP. Proposed algorithm is compared output power error to conventional algorithm with radiation and temperature changing. In addition, the validity of the algorithm is proved through the output error response characteristics.

UPS용 인버터 출력특성 개선 (The Characteristic Improvement of Inverter Output for Static UPS)

  • 김동욱;김연풍;신현주;백병산;류승표;민병권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2051-2053
    • /
    • 1998
  • In spite of nonlinear or step-changing load and line disturbances, the inverter for the UPS must provide the pure sinusoidal output voltage with low THD(Total Harmonics Distortion). This paper proposes an inverter controller for the UPS which has a good dynamic response characteristic and robustness for applying industrial world directly. The inverter output voltage is controlled instantaneously with a double regulation loop by a TMS320C31 Digital Signal Processor so that it has very good dynamic response for nonlinear or step-changing load and line disturbances. To improve the voltage utilization and response characteristics, the Space Vector Modulation(SVM) technique is adapted for the switching method of this system. The characteristics of the proposed control system were verified by simulations and experiments.

  • PDF

일대다 연결 고려한 ATM 망에서의 최적 루팅 (An Optimal Routing for Point to Multipoint Connection Traffics in ATM Networks)

  • 정성진;홍성필;정후상;김지호
    • 대한산업공학회지
    • /
    • 제25권4호
    • /
    • pp.500-509
    • /
    • 1999
  • In this paper, we consider an optimal routing problem when point-to-point and point-to-multipoint connection traffics are offered in an ATM network. We propose a mathematical model for cost-minimizing configuration of a logical network for a given ATM-based BISDN. Our model is essentially identical to the previous one proposed by Kim(Kim, 1996) which finds a virtual-path configuration where the relevant gains obtainable from the ATM technology such as the statistical multiplexing gain and the switching/control cost-saving gain are optimally traded-off. Unlike the Kim's model, however, ours explicitly considers the VP's QoS(Quality of Service) for more efficient utilization of bandwidth. The problem is a large-scale, nonlinear, and mixed-integer problem. The proposed algorithm is based on the local linearization of equivalent-capacity functions and the relaxation of link capacity constraints. As a result, the problem can be decomposed into moderate-sized shortest path problems, Steiner arborescence problems, and LPs. This fact renders our algorithm a lot faster than the previous nonlinear programming algorithm while the solution quality is maintained, hence application to large-scale network problems.

  • PDF

A Hybrid Static Compensator for Dynamic Reactive Power Compensation and Harmonic Suppression

  • Yang, Jia-qiang;Yang, Lei;Su, Zi-peng
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.798-810
    • /
    • 2017
  • This paper presents a combined system of a small-capacity inverter and multigroup delta-connected thyristor switched capacitors (TSCs). The system is referred to as a hybrid static compensator (HSC) and has the functions of dynamic reactive power compensation and harmonic suppression. In the proposed topology, the load reactive power is mainly compensated by the TSCs. Meanwhile the inverter is meant to cooperate with TSCs to achieve continuous reactive power compensation, and to filter the harmonics generated by nonlinear loads and the TSCs. First, the structure and mathematical model of the HSC are discussed Then the control method of the HSC is presented. An improved reduced order generalized integrator (ROGI)-based selective current control method is adopted in the inverter to achieve high-performance reactive and harmonic current compensation. Meanwhile, a switch control strategy is proposed to implement precise and fast switching of the TSCs and to avoid changing the time delay needed by the conventional switch strategy. Experiments are implemented on a 20 KVA HSC prototype and the obtained results verify the validity of the proposed HSC system.

LLC 공진형 컨버터 제어시스템 설계 (Design of Control System for LLC Resonant Converter)

  • 김의현;안현식
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.129-137
    • /
    • 2017
  • 본 논문에서는, 스위칭 손실이 적고 효율이 높은 이점을 갖고 있는 LLC 공진형 컨버터에 대하여 선형화된 수학적 모델을 정립하고 디지털 제어기 설계 과정을 제안한다. LLC 공진형 컨버터의 비선형 모델에 대하여 EDF(Extended Describing Function) 기법을 도입하여 비선형성을 선형 근사화시킨 선형 소신호 모델을 정립하고 Ziegler Nichols 방법을 이용하여 제어기 계수를 선정하였으며 연속시간 제어기를 디지털 제어기로 변환하여 적용한다. 유도된 선형 소신호 모델에 기반하여 전압 제어기를 설계하고, MATLAB 시뮬레이션을 통하여 제어기의 성능을 검증한다. 또한, 부하 변화 및 모델링 오차를 고려한 시뮬레이션을 통하여 LLC 공진형 컨버터에 대해 설계된 전압 제어기의 타당성 및 제어성능을 분석한다.

슬라이딩 모드 관측기와 제어기를 이용한 서보시스템의 정밀제어 (Precise Control for Servo Systems Using Sliding Mode Observer and Controller)

  • 한성익;공준희;신대왕;김종식
    • 한국정밀공학회지
    • /
    • 제19권7호
    • /
    • pp.154-162
    • /
    • 2002
  • The effect of nonlinear friction in the low velocity is dominant in precise controlled mechanisms and it is difficult to model. This paper is concerned with the compensation for friction using the variable structure system approach as nonmodel based method. The problem of chattering in the sliding mode controller is suppressed by the implementation of the boundary layer concept. And the estimation for friction using sliding mode observer makes the upper bound of matched uncertainty reduced. Accordingly, the effect of chattering can be more suppressed. And the sliding surface is constructed by adding an integral component to the switching function that is made by using error dynamics. This sliding surface guarantees the good tracking performance. Experimental results for a XY table system show that the proposed method has a good performance especially in the low velocity.

이중 탱크 시스템의 정밀 수위 제어를 위한 RVEGA SMC에 관한 연구 (RVEGA SMC for Precise Level Control of Coupled Tank System)

  • 김태우;이준탁
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.102-108
    • /
    • 1999
  • 슬라이딩 모드 제어기(SMC)는 파라미터의 변동과 급격한 외란을 가진 이중 탱크 시스템과 같은 비선형 제어 시스템에 대해 견실성을 갖는 가변구조로써 널리 알려져 있다. 그러나, 이러한 파라미터에 대한 적응 동조 알고리즘은 만족하지 못한다. 그러므로, 본 논문에서는 이중 탱크 시스템의 정밀한 수위제어를 하기 위해 슬라이딩 모드에 기반을 둔 실변수 유전 알고리즘(RVEGA SMC)을 시도하였다. SMC의 스위칭 파라미터는 RVEGA에 의해 쉽고, 빠르게 최적화 되었다. 시뮬레이션 결과에서는 제안된 RVEGA SMC에 의해 탱크의 수위가 오버슈트나 정상상태 오차 없이 만족한 제어결과를 보여준다.

  • PDF

Stability and Performance Investigations of Model Predictive Controlled Active-Front-End (AFE) Rectifiers for Energy Storage Systems

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.202-215
    • /
    • 2015
  • This paper investigates the stability and performance of model predictive controlled active-front-end (AFE) rectifiers for energy storage systems, which has been increasingly applied in power distribution sectors and in renewable energy sources to ensure an uninterruptable power supply. The model predictive control (MPC) algorithm utilizes the discrete behavior of power converters to determine appropriate switching states by defining a cost function. The stability of the MPC algorithm is analyzed with the discrete z-domain response and the nonlinear simulation model. The results confirms that the control method of the active-front-end (AFE) rectifier is stable, and that is operates with an infinite gain margin and a very fast dynamic response. Moreover, the performance of the MPC controlled AFE rectifier is verified with a 3.0 kW experimental system. This shows that the MPC controlled AFE rectifier operates with a unity power factor, an acceptable THD (4.0 %) level for the input current and a very low DC voltage ripple. Finally, an efficiency comparison is performed between the MPC and the VOC-based PWM controllers for AFE rectifiers. This comparison demonstrates the effectiveness of the MPC controller.