• Title/Summary/Keyword: Nonlinear phase

Search Result 1,080, Processing Time 0.027 seconds

A Study on the Nonlinear Instability Behavior of Hybrid Structures(II) -Characteristic of Dynamic In-Plane Torsional Buckling under the STEP Load- (Hybrid 구조물의 비선형 불안정 거동에 관한 연구(II) -STEP 하중에서의 동적 면내비틀림 좌굴 특성-)

  • Kim, Seung Deog;Kim, Hyung Seok;Kang, Moon Myung
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.5
    • /
    • pp.599-608
    • /
    • 2001
  • Many papers which deal with the dynamic instability of shell-like structures under the STEP load has been published but there have been few papers related to the dynamic instability of hybrid cable domes. And also there are a few researches which treat the essential phenomenon of the dynamic buckling using the phase for investigating occurrence of chaos. In this study the indirect buckling of hybrid cable domes considering geometric nonlinearity are investigated numerically and compared it with the static critical load The dynamic critical loads are determined by the numerical integration of the geometric nonlinear equation of motion and the mechanism of the indirect buckling is examined by using the phase curves.

  • PDF

ACCURACY AND EFFICIENCY OF A COUPLED NEUTRONICS AND THERMAL HYDRAULICS MODEL

  • Pope, Michael A.;Mousseau, Vincent A.
    • Nuclear Engineering and Technology
    • /
    • v.41 no.7
    • /
    • pp.885-892
    • /
    • 2009
  • This manuscript will discuss a numerical method where the six equations of two-phase flow, the solid heat conduction equations, and the two equations that describe neutron diffusion and precursor concentration are solved together in a tightly coupled, nonlinear fashion for a simplified model of a nuclear reactor core. This approach has two important advantages. The first advantage is a higher level of accuracy. Because the equations are solved together in a single nonlinear system, the solution is more accurate than the traditional "operator split" approach where the two-phase flow equations are solved first, the heat conduction is solved second and the neutron diffusion is solved third, limiting the temporal accuracy to $1^{st}$ order because the nonlinear coupling between the physics is handled explicitly. The second advantage of the method described in this manuscript is that the time step control in the fully implicit system can be based on the timescale of the solution rather than a stability-based time step restriction like the material Courant limit required of operator-split methods. In this work, a pilot code was used which employs this tightly coupled, fully implicit method to simulate a reactor core. Results are presented from a simulated control rod movement which show $2^{nd}$ order accuracy in time. Also described in this paper is a simulated rod ejection demonstrating how the fastest timescale of the problem can change between the state variables of neutronics, conduction and two-phase flow during the course of a transient.

Power Loss Analysis of Transformer Caused By Current Harmonics (전류 고조파에 기인하는 변압기 손실 해석)

  • Jang, Seungyong;Han, Sanghoon;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.1
    • /
    • pp.34-41
    • /
    • 2016
  • This study investigates transformer losses caused by current harmonics. Electrical transformers are designed to work under sinusoidal voltage and current waves at a rated frequency. Recently, various nonlinear loads, such as power electronic converters, are connected to a power system; these converters generate current harmonics. Current harmonics increase power loss in transformers, which results in several problems, including temperature increase of the transformer and insulation damage. These problems will eventually shorten the operational life of the transformer. In this study, different types of losses caused by current harmonics in three-phase transformers are studied under linear and nonlinear load conditions. Linear loads are simulated and experimented on using pure resistance load, whereas nonlinear loads are simulated and experimented on using a three-phase twelve-pulse thyristor full-bridge rectifier. The different types of losses in three-phase transformers are evaluated analytically through the experimental result and simulation in PSiM.

Study on Phase-Segregated Active Power Filter using PLECS

  • Zhang, Ying-Hao;Oh, Hyoung-Lok;Lim, Han-Jun;Zhang, Wen-Hao;Kim, Du-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.216-217
    • /
    • 2013
  • This paper presents an algorithm for a phase-segregated active power filter for three-phase electric system. Due to the symmetrical characteristic of three-phase system and the specialty of distribution system, the proposed algorithm focuses on the extraction of harmonic component of load current in each phase and simulations have been done by PLECS software to verify the validity of the proposed algorithm while loads are nonlinear.

  • PDF

Neutral Current Reduction Method Using Single-Phase Inverter (단상 인버터를 사용한 중성선 전류 저감 기법)

  • Min, Joon-Ki;Kim, Hyo-Sung;Choi, Jao-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.155-157
    • /
    • 2005
  • This paper analyzed the adoption possibility of a low cost single phase active power filter as the neutral current reduction device in three-phase four-wire power system with the balanced or/and unbalnaced nonlinear load conditions. Proposed system can make neutral line current to within rated vale without the phase current THD change of the installed phase line.

  • PDF

The Phenomena Giving Rise of Nonlinear Load Operated by Unbalance Voltage (불평형 전압으로 운전시 비선형 부하에 나타나는 현상)

  • Kim, Jong-Gyeom;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.285-291
    • /
    • 2002
  • In general, utility voltage is maintained at a relatively low level of Phase unbalance since a low level of unbalance can cause a significant power supply ripple and heating effects on the power system equipment. Voltage unbalance more commonly emerges in individual customer loads due to phase load unbalanced, especially where single phase power loads are used. Under unbalanced input voltages large lower order harmonics appears at the input and output ports of Power conversion devices. As the application of adjustable -speed drives (ASDs) and their integration with complex industrial processes increase, so does the need to understand how ASDs perform during voltage This paper describes a real load test to investigate the performance of 3-HP adjustable speed drives by an unbalanced voltage at the low-voltage system.

Optimal Position of Optical Phase Conjugator for Compensation of Distorted WDM Signals with Initial Frequency Chirp

  • Lee Seong-Real;Choi Byung-Ha;Chung Myung-Rae
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.1
    • /
    • pp.36-42
    • /
    • 2005
  • In this paper, the optimal position of optical phase conjugator(OPC) excellently compensating distorted WDM channels with initial frequency chirp due to both chromatic dispersion and self phase modulation(SPM) is numerically investigated. Highly-nonlinear dispersion shifted fiber(HNL-DSF) is used as a nonlinear medium of OPC in order to widely compensate WDM signal band. It is confirmed that if the OPC position was shifted from mid-way of total transmission length dependence on the initial frequency chirp as well as modulation format and fiber dispersion coefficient, it is possible to cancel the performance degradation owing to the initial frequency chirp. Using proposed configuration, it is possible to remove all in-line dispersion compensator, reducing span losses and system costs in the long-haul broadband WDM systems.

Power Quality Disturbance Generator with Arbitrary Phase Jump and Voltage Control for Nonlinear Load (비선형 부하를 위한 임의의 위상 급변 및 전압제어가 가능한 전력품질 외란 발생기)

  • Park, P.S.;Nho, E.C.;Kim, I.D.;Choi, N.S.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.146-148
    • /
    • 2006
  • This paper deals with a simple structured power quality disturbance generator for nonlinear load devices. The proposed generator can be applied to the performance test of custom power devices. Voltage sag, swell, outage, unbalance and phase jump after outage are provided by the generator. The improving phase jump operating principle of the generator is described and analysed. The usefulness of the generator is verified through simulation.

  • PDF

Compensation for Distorted Signals by using Optimal Pump Light Power in WDM Systems with Non-midway Optical Phase Conjugator

  • Lee Seong-Real
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.7A
    • /
    • pp.542-549
    • /
    • 2005
  • In this paper, the optimal pump light power of optical phase conjugator (OPC) and the compensation characteristics of distorted WDM channel signals are numerically investigated, when the OPC with highly-nonlinear dispersion shifted fiber (HNL-DSF) not be placed at the mid-way of total transmission length. The total dispersion of former half section and latter half section is assumed to be same each other in this approach. It is confirmed that, in WDM transmission systems with OPC deviated from the mid-way, the pump light power for best compensation must be flexible selected depending on the OPC position. This optimal pump light power is gradually increased as the OPC is gradually closer to the receiver. Consequently, it is possible to establish the compensation system independent on the OPC position by setting optimal pump light power connected with the OPC position.

Nonlinear Optical Behavior of Binary Mixture Protein and Water near the Phase Separation Temperature (두 종류 임계 섞임체 단백질-물의 상전이 온도 근방에서 비선형 광학적 특성)

  • Cho, Chang-Ho;Seo, Young-Seok;Kim, Chil-Min;Park, Jong-Dae;Lee, Jong-Soo
    • The Journal of Natural Sciences
    • /
    • v.9 no.1
    • /
    • pp.83-88
    • /
    • 1997
  • The critical behavior was studied in the mixture of lysozyme and salt water near the phase separation temperature. The 3rd order nonlinear optical susceptibility was measured through the self-induced ellipse rotation. And we obsered that as the quantity of salt and glycerol increase, the phase separation temperature increases and decreases, respectively.

  • PDF