• 제목/요약/키워드: Nonlinear Hysteretic Analysis

검색결과 161건 처리시간 0.027초

Bouc-Wen 모델을 이용한 차량동역학 해석용 1축 부싱모델의 개발 (Development of Uni-Axial Bushing Model for the Vehicle Dynamic Analysis Using the Bouc-Wen Hysteretic Model)

  • 옥진규;유완석;손정현
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.158-165
    • /
    • 2006
  • In this paper, a new uni-axial bushing model for vehicle dynamics analysis is proposed. Bushing components of a vehicle suspension system are tested to capture the nonlinear and hysteric behavior of the typical rubber bushing elements using the MTS machine. The results of the tests are used to develop the Bouc-Wen bushing model. The Bouc-Wen model is employed to represent the hysteretic characteristics of the bushing. ADAMS program is used for the identification process and VisualDOC program is also used to find the optimal coefficients of the model. Genetic algorithm is employed to carry out the optimal design. A numerical example is suggested to verify the performance of the proposed model.

비선형 수치해석을 통한 단자유도 얕은기초 구조물의 지진 응답특성 검증 (Verification of Nonlinear Numerical Analysis for Seismic Response of Single Degree of Freedom Structure with Shallow Foundation)

  • 추연욱;이진선;김동수
    • 한국지반공학회논문집
    • /
    • 제29권3호
    • /
    • pp.29-40
    • /
    • 2013
  • 본 논문에서는 얕은기초를 가지는 단자유도 구조물의 지진시 응답특성을 시간영역 비선형 유한차분해석을 이용하여 살펴보았다. 해석결과는 중력가속도 20g에서 시행된 동일한 제원을 가지는 동적원심모형실험 결과를 통하여 검증되었다. 검증결과 실험과 해석의 통제운동지점 경계조건 차이에서 발생하는 차이는 지반의 비선형 거동특성으로 발생하는 이력감쇠에 지반의 감쇠비를 추가하여 감소시킬 수 있었다. 이로부터 얻어진 구조물과 지반에서 계측된 가속도 시간이력 및 주파수대역 응답곡선 모두 유사한 결과를 나타내어, 시간영역 비선형 유한차분해석을 통한 지반-구조물 상호작용 해석의 신뢰성을 확보할 수 있었으며, 향후 동적원심모형으로 계측이 어려운 구조물의 잔류변위, 작용토압 등을 효과적으로 판단할 수 있을 것으로 사료된다.

강재 코일 댐퍼의 배관시스템 진동제어 효과 분석을 위한 진동대시험 (Shaking Table Test for Analysis of Effect on Vibration Control of the Piping System by Steel Coil Damper)

  • 최송이;소기환;조성국
    • 한국지진공학회논문집
    • /
    • 제26권1호
    • /
    • pp.39-48
    • /
    • 2022
  • Many piping systems installed in the power plant are directly related to the safety and operation of the plant. Various dampers have been applied to the piping system to reduce the damage caused by earthquakes. In order to reduce the vibration of the piping system, this study developed a steel coil damper (SCD) with a straightforward structure but excellent damping performance. SCD reduces the vibration of the objective structure by hysteretic damping. The new SCD damper can be applied to high-temperature environments since it consists of steel members. The paper introduces a design method for the elastoplastic coil spring, which is the critical element of SCD. The practical applicability of the design procedure was validated by comparing the nonlinear force-displacement curves calculated by design equations with the results obtained from nonlinear finite element analysis and repeated loading test. It was found that the designed SCD's have a damping ratio higher than 25%. In addition, this study performed a set of seismic tests using a shaking table with an existing piping system to verify the vibration control capacity on the piping system by SCD. Test results prove that the SCD can effectively control the displacement vibration of the piping system up to 80%.

Dynamic loading tests and analytical modeling for high-damping rubber bearings

  • Kyeonghoon Park;Taiji Mazda;Yukihide Kajita
    • Earthquakes and Structures
    • /
    • 제25권3호
    • /
    • pp.161-175
    • /
    • 2023
  • High-damping rubber bearings (HDRB) are commonly used as seismic isolation devices to protect civil engineering structures from earthquakes. However, the nonlinear hysteresis characteristics of the HDRB, such as their dependence on material properties and hardening phenomena, make predicting their behavior during earthquakes difficult. This study proposes a hysteretic model that can accurately predicts the behavior of shear deformation considering the nonlinearity when designing the seismic isolation structures using HDR bearings. To model the hysteretic characteristics of the HDR, dynamic loading tests were performed by applying sinusoidal and random waves on scaled-down specimens. The test results show that the nonlinear characteristics of the HDR strongly correlate with the shear strain experienced in the past. Furthermore, when shear deformation occurred above a certain level, the hardening phenomenon, wherein the stiffness increased rapidly, was confirmed. Based on the experimental results, the dynamic characteristics of the HDR, equivalent stiffness, equivalent damping ratio, and strain energy were quantitatively evaluated and analyzed. In this study, an improved bilinear HDR model that can reproduce the dependence on shear deformation and hardening phenomena was developed. Additionally, by proposing an objective parameter-setting procedure based on the experimental results, the model was devised such that similar parameters could be set by anyone. Further, an actual dynamic analysis could be performed by modeling with minimal parameters. The proposed model corresponded with the experimental results and successfully reproduced the mechanical characteristics evaluated from experimental results within an error margin of 10%.

형상기억합금을 이용한 슬릿댐퍼 적용 역V형 편심가새골조의 내진 성능 (Seismic Performance of an Inverted V-type Eccentrically Braced Steel Frames with Slit Dampers Using Shape Memory Alloy)

  • 장한렬;김주우
    • 한국공간구조학회논문집
    • /
    • 제22권4호
    • /
    • pp.39-48
    • /
    • 2022
  • The energy dissipation of inverted V-type eccentric steel braced frames can be achieved through the yielding of a slit link, through yielding of a number of strips between slits when the frame is subjected to inelastic cyclic deformation. On the other hand, the development of seismic resistance system without residual deformation is obtained by applying the superelasdtic shape memory alloy (SMA) material into the brace and link elements. This paper presents results from a systematic three-dimensional nonlinear finite element analysis on the structural behavior of the eccentric bracing systems subjected to cyclic loadings. A wide scope of structural behaviors explains the horizontal stiffness, hysteretic behaviors, and failure modes of the recentering eccentric bracing system. The accurate results presented here serve as benchmark data for comparison with results obtained using modern experimental testing and alternative theoretical approaches.

지진하중에 의한 구조물의 비선형 거동 예측 (Prediction of Nonlinear Seismic Response)

  • 김희중
    • 한국강구조학회 논문집
    • /
    • 제8권4호통권29호
    • /
    • pp.77-84
    • /
    • 1996
  • The structural members under seismic loading actually show inelastic behavior, so the inelastic responses should be calculated for the seismic design of structures or estimating the structural damage level. Although direct time history analysis may calculate the exact dynamic nonlinear responses for given ground motions, this approach involves a high computational cost and long period. Therefore, it should be developed the approach to estimate nonlinear responses for the practical purpose. The artificial earthquake accelerograms were generated to obtain the smoothed responses spectra, and the samples of generated accelerogram for each seismic event was used to examine average nonlinear response spectra. The stabilized response spectra for each earthquake event was used to evaluate the effects of various yield strength ratios, damping values and nonlinear hysteretic models. The approach, which can simply predict the nonlinear seismic responses of structures, was shown in this study.

  • PDF

지진시 저층건물 면진구조의 비선형 동적 거동 (Dynamic Stability Analysis of Base-Isolated Low-level Nonlinear Structure Under Earthquake Excitation)

  • 문병영;강경주;강범수;김계수
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1743-1750
    • /
    • 2001
  • This paper presents an analysis of nonlinear response of the seismically isolated structure against earthquake excitation to evaluate isolation performances of a rubber bearing. In the analysis of the vibration of building, the building is modeled by lumped mass system where the restoring force is considered as linear, bilinear and trilinear. Fundamental equations of motion are derived for the base isolated structure, and hysteretic and nonlinear-elastic characteristics are considered for a numerical calculation. The excitation levels are magnified fur the recorded strong earthquake motions in order to examine dynamic stability of the structure. Seismic responses (of the building are compared fur the each restoring force type. As a result, it is shown that the effect of the motion by the nonlinear response of the building is comparatively not so large from a seismic design standpoint. The responses of the isolated structures reduce sufficiently and controled the motion of the building well in a practical range. By increasing the acceleration of the earthquake, the yielding of the farce was occurred in the concrete and steel frame, which shows the necessity of the exact nonlinear dynamic analysis.

Semi-rigid connection modeling for steel frameworks

  • Liu, Yuxin
    • Structural Engineering and Mechanics
    • /
    • 제35권4호
    • /
    • pp.431-457
    • /
    • 2010
  • This article provides a discussion of the mathematic modeling of connections for designing and qualifying structures, systems, and components subject to monotonic or cyclic loading. To characterize the force-deformation behavior of connections under monotonic loading, a review of the Ramberg-Osgood, Richard-Abbott, and Menegotto-Pinto models is conducted, and it is shown that these nonlinear functions can be mathematically derived by scaling up or down a linear force-deformation function. A generalized four-parameter model for simulating connection behavior is investigated to facilitate nonlinear regression analysis. In order to perform seismic analysis of frameworks, a hysteretic model accounting for loading, unloading, and reloading is described using the established monotonic model. For preliminary analysis, a method is provided to quickly determine the model parameters that fit approximately with the observed data. To reach more accurate values of the parameters, the methods of nonlinear regression analysis are investigated and the modified Levenberg-Marquardt and separable nonlinear least-square algorithms are applied in determining the model parameters. Example case studies illustrate the procedure for the computation through the use of experimental/analytical data taken form the literature. Transformation of connection curves from the three-parameter model to the four-parameter model for structural analysis is conducted based on the modeling of connections subject to fire.

Distribution of Optimum Yield-Strength and Plastic Strain Energy Prediction of Hysteretic Dampers in Coupled Shear Wall Buildings

  • Bagheri, Bahador;Oh, Sang-Hoon;Shin, Seung-Hoon
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1107-1124
    • /
    • 2018
  • The structural behavior of reinforced concrete coupled shear wall structures is greatly influenced by the behavior of their coupling beams. This paper presents a process of the seismic analysis of reinforced concrete coupled shear wall-frame system linked by hysteretic dampers at each floor. The hysteretic dampers are located at the middle portion of the linked beams which most of the inelastic damage would be concentrated. This study concerned particularly with wall-frame structures that do not twist. The proposed method, which is based on the energy equilibrium method, offers an important design method by the result of increasing energy dissipation capacity and reducing damage to the wall's base. The optimum distribution of yield shear force coefficients is to evenly distribute the damage at dampers over the structural height based on the cumulative plastic deformation ratio of the dissipation device. Nonlinear dynamic analysis indicates that, with a proper set of damping parameters, the wall's dynamic responses can be well controlled. Finally, based on the total plastic strain energy and its trend through the height of the buildings, a prediction equation is suggested.

철골 모멘트 골조의 지진해석을 위한 등가 단자유도시스템 (Equivalent SDF Systems Representing Steel Moment Resisting Frames)

  • 한상환;문기훈;김진선
    • 한국지진공학회논문집
    • /
    • 제12권3호
    • /
    • pp.21-28
    • /
    • 2008
  • 다자유도 시스템의 내진 성능을 평가하기 위해서는 반복적인 비선형 시간 이력 해석이 필요하며 이를 위해 많은 계산과정과 노력이 필요하다. 이와 같이 해석에 따르는 어려움을 보완하기 위해 복잡한 다자유도 시스템을 반영할 수 있는 등가 단자유도 시스템을 개발하였다. 등가 단자유도의 이력 모델로는 일반적으로 이선형 모델과 삼선형 모델이 사용된다. 이러한 모델은 탄성 거동 이후 음강성을 가질 수 있도록 하여 지진 발생 시 중력하중에 의한 발생되는 효과를 반영하기 위해서이다. 본 연구에서는 철골모멘트 골조의 실제 응답을 예측하기 위하여 이러한 이력 모델들로 거동하는 등가단자유도 시스템의 필요조건에 대하여 평가하였다. 이를 위해 본 연구에서는 로스엔젤레스 지역의 SAC 9층 모멘트 저항 골조를 비선형 다자유도 시스템과 등가단자유도 시스템으로 모델링하여 반복하중 푸쉬오버 해석, 비선형 시간 이력해석 및 IDA(Incremental Dynamic Analysis)를 수행하여 비교 검토하였다. 또한 본 연구에서는 강도저감 모델에 대해서도 평가를 수행하였다.