• 제목/요약/키워드: Noncontact mode

검색결과 22건 처리시간 0.033초

전자기 초음파를 이용한 CFRP 복합적층판의 적층배향 특성평가에 관한 연구 (A Study on Characterization for Stacking Fault Evaluation of CFRP Composite Laminates Using an EMAT Ultrasonics)

  • 임광희;나승우;김지훈;이창노;;양인영
    • 한국자동차공학회논문집
    • /
    • 제13권2호
    • /
    • pp.83-92
    • /
    • 2005
  • An electromagnetic acoustic transducer (EMAT) is a unique probe that does not require a couplant or gel and also can usually generate or detect an ultrasonic wave into specimens across a small gap. It, therefore can be applied in a noncontact mode with a high degree of reproducibility. Especially stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates. It is very important to evaluate the layup errors in prepreg laminates. A nondestructive technique can therefore serve as a useful measurement for detecting layup errors. This shear wave for detecting the presence of the errors is very sensitive. A decomposition model has been used in the interpretation and prediction of test results. Test results have been com pared with model data. It is found that the high probability shows between tests and the model utilized in characterizing cured layups of the laminates. Also a C-scan method was used for detecting layup of the laminates because of extracting fiber orientation information from the ultrasonic reflection caused by structural imperfections in the laminates. Therefore, it was found that interface C-scan images show the fiber orientation information by using two-dimensional fast Fourier transform (2-D FFT).

치은연하치석제거술시 Nd : YAG 레이저를 이용한 효과에 관한 주사전자현미경적 연구 (The Scanning Electron Microscopic study on the effect during subgingival calculus removal using Nd:YAG laser)

  • 전용선;최병선;이석초;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제27권2호
    • /
    • pp.411-424
    • /
    • 1997
  • The purpose of this study was to evaluate in vitro the effects during subgingival calculus removal using Nd:YAG laser. The study group was consisted of 30 teeth with advanced periodontal disease extracted before the start of periodontal therapy. The specimens were divided into 8 different groups : 1) untreated control 2) scaling and root planing only 3) laser treated using 150mJ/pulse, 1sec, 5sec, contact mode 4) laser treated using 200mJ/pulse, 5sec, contact mode 5) laser treated using 150mJ/pulse, 1sec, non-contact mode 6) laser treated using 200mJ/pulse, 5sec, non-contact mode 7) laser treated using l5OmJ/pulse, 1sec, contact mode with water irrigation 8) laser treated using 200mJ/pulse, 5sec, contact mode with water irrigation. All specimens were prepared for evaluation by scanning electron microscopy(SEM). Specimens from Group 2 exhibited a smear layer of scale like texture with parallel instrument tracks resulting from curet use. Specimens treated by contact mode, Group 3 and 4 featured surface changes not observed· in controls such as charring, randomly distributed pitting and crater formation, and melting down of the tooth material and calculus. Specimens treated by noncontact mode, Group 5 and 6 featured similar surface changes observed in contact mode. However, the differences between contact and non-contact groups not significant. Specimens treated by contact mode with water irrigation, Group 7 and 8 featured slight surface change compared to other groups. The results suggested that Nd: YAG laser did not completely remove the subgingival calculus but was possible the application as adjunctive method.

  • PDF

모드 선택성을 강화한 비접촉식 유도초음파 기술 (Non-Contact Guided Wave Technique with Enhanced Mode-Selectivity)

  • 김현묵;이태훈;장경영
    • 비파괴검사학회지
    • /
    • 제24권6호
    • /
    • pp.597-602
    • /
    • 2004
  • 유도초음파의 현장적응에 있어 전파모드를 규명하는 것은 매우 어렵지만 중요한 과제이다. 본 연구에서는 분산성이 적은 단일모드를 발생시키고 검출할 수 있는 기법에 대해 다루고 있으며, 현장 적용성과 자동화를 위해 비접촉식의 기법을 적용하였다. 모드 선택성을 강화한 비접촉식의 유도초음파 기법으로는 선배열 슬릿을 이용한 레이저빔을 이용하였으며, 에어커플 변환기를 수신자로 사용하였다. 선배열의 레이저 조명은 파장과 일치하여 특정한 모드를 발생시킬 수 있다 또한, 에어커플 변환기는 공기 중으로 누설되는 유도초음파를 수신각도를 조절하여 선택적으로 모드를 수신할 수 있다. 1mm 두께의 알루미늄 판에 덕 기법을 적용한 실험결과로부터 제안하는 기법의 유용성을 검증하였고, 특히 단일한 $a_0$모드의 발생 및 수신에 효과적인 기법으로 나타났다.

전자기 음향 공진을 이용한 강선의 표면 미세 결함 탐상 타당성 연구 (Feasibility Study on Surface Microcrack Detection of the Steel Wire Rods Using Electromagnetic Acoustic Resonance)

  • 허태훈;조승현;안봉영;임종수
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.7-13
    • /
    • 2013
  • 철강 생산 제품 중 강선 (steel wire rod)은 제조 과정 중 종방향으로 미세한 표면 결함이 매우 빈번하게 발생하는데 이중 깊이가 수 십 마이크로미터 이상인 결함들은 최종 생산품의 불량을 유발하는 심각한 원인이 되고 있다. 이와 같은 이유로 강선의 제조 단계에서 표면의 미세 결함의 깊이를 평가하는 방법의 개발이 절실히 요구된다. 표면 미세 결함을 평가할 수 있는 여러 가지 방법 중에서, 본 연구에서는, 전자기 음향공진법의 적용 가능성을 고찰하고자 한다. 전자기 음향 공진 (electromagnetic acoustic resonance, EMAR)은 전자기 음향 트랜스듀서 (electromagnetic acoustic transducer, EMAT)을 이용하여 시편의 공진 특성을 측정하는 방법으로서, 대상의 작은 변화에도 민감하게 반응하고 비접촉 측정이 가능하여 현장 적용에 용이하다는 장점이 있다. 전자기 음향 공진 실험을 통하여 표면 미세결함과 잔향특성의 변화를 관찰하여 깊이 약 100 마이크로미터 내외의 결함은 탐상 가능함을 확인하였다.

비접촉식 와전류형 제동 장치의 최적 토오크 제어 (Optimal torque control of noncontact type eddy current brake system)

  • 이갑진;박기환;류제하
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.261-264
    • /
    • 1997
  • A contactless eddy current type braking system is developed to take advantages of the recent brake system which uses hydraulic force can show high efficiency in a certain velocity region, but not in a high velocity region, and has initial response delay time and pressure build-up time which make stopping distance longer. These are the limits of mechanical brake system of a contact type, which makes a concept brake system required. So, in this paper, the contactless brake system .of a inductive current type is chosen instead of hydraulic brake system. This brake system can be used almost forever for being no wear and contributed to lightening weight of a vehicle. Besides, the contactless brake system can be used as that of electric or solar car with anti-lock brake system. The analysis of induced electromotive force and braking torque obtained with theoretical approximate model, the design of a braking system and a nonlinear controller, and the results of simulation of the ABS, experiment are included.

  • PDF

강판운송을 위한 자기부상기술에 관한 연구 (A Study on the Magnetic Levitation Technology for Iron Plate Conveyance)

  • 조경재;차인수;이권현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.95-98
    • /
    • 1998
  • Applying the magnetically levitated transportation system, which is noncontact bearing system, to solve the problems such as transformation of original form or flaw of iron plate caused by transportation of thin iron plate which required high quality as body of motor vehicle, materials of electronic devices etc.. Magnetic saturation phenomena caused by thickness of iron plate and gap size between magnets. In case of iron plate, the vibration mode will be considered since vibration occurs during transportation. In order to solve the problems caused by vibration, choose the levitation system method using numbers of magnet, magnetic saturation for thickness and length of iron plate with parameters in location and gap of magnet. In this paper, we will suggest the whole design technique of magnetically levitated transportation system, namely method of magnetic attraction and transportation system

  • PDF

주철 FC200을 이용한 하중점에 따른 동적파괴경로 예측 연구 (Study on Dynamic Fracture Path Prediction According to Load Point using Cast Iron FC200)

  • 유직수;조규춘
    • 한국산업융합학회 논문집
    • /
    • 제27권4_2호
    • /
    • pp.973-980
    • /
    • 2024
  • Dependence of dynamic fracture path on loading velocity was observed from experimental results based on the three point bending fracture in cast iron. In this study, 3D and 2D numerical simulations are used to evaluate singular stress fields near crack tip and fracture mechanics parameters. Moving finite element technique, 2D and 3D Delauney automatic mesh generation and contact-noncontact evaluation is introduced into the numerical method. Dynamic fracture thoughness is decreased with increase of impact loading velocity. Fracture mode-ratio corresponds to initial kink angle of fracture path. The numerical result shows that the maximum hoop stress criterion cannot be applied to dynamic fracture of cast iron.

구강병소에 대한 펄스형 Nd: YAG 레이저의 치료효과 (The Therapeutic Effects of a Pulsed Nd:YAG Laser on Oral Lesions)

  • 신금백
    • Journal of Oral Medicine and Pain
    • /
    • 제22권2호
    • /
    • pp.309-325
    • /
    • 1997
  • In order to set the lasing variables and evaluate, clinically, the therapeutic effects of a pulsed Nd:YAG laser on oral lesion, the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (wavelength 1064nm, Pulse duration 120$\mu$sec, fiber diameter 200$\mu$m/320$\mu$m) to 22 cases of oral soft tissue lesions and 6 cases of oral hard tissue lesions. The obtained results were as follows : 1. The effective excision with contact mode and the effective hemostasis of accompanied bleeding with noncontact mode were occurred by lasing on oral soft tissue lesions with fiber diameter of 320$\mu$m under the variables of 2.0~4.0W and 20~50Hz which were controlled into high power/low pulses for excision, low power/high pulses for hemostasis, low power in granulation tissue and high power in fibrous tissue according to therapeutic goals and tissue conditions. 2. About 50% of decreasing effect on hypersensitivity was occurred by lasing with non-contact and contact mode on cervical abrasion which caused dentinal hypersensitivity with fiber diameter of 320$\mu$m under the variables of 0.7 - 1.0W and 10Hz which were applied 2~3 times with 1 week interval. 3. The effective sterilization of infected root canal and lesion of periapical abscess was occurred by lasing with contact and spiral modes on wall of root canal and periapical abscess with fiber diameter of 200$\mu$m of which the tip was placed about 1mm shorter than root canal length under the variables of 1.OW and 10Hz.

  • PDF

Nondestructive inspection of spent nuclear fuel storage canisters using shear horizontal guided waves

  • Choi, Sungho;Cho, Hwanjeong;Lissenden, Cliff J.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.890-898
    • /
    • 2018
  • Nondestructive inspection (NDI) is an integral part of structural integrity analyses of dry storage casks that house spent nuclear fuel. One significant concern for the structural integrity is stress corrosion cracking in the heat-affected zone of welds in the stainless steel canister that confines the spent fuel. In situ NDI methodology for detection of stress corrosion cracking is investigated, where the inspection uses a delivery robot because of the presence of the harsh environment and geometric constrains inside the cask protecting the canister. Shear horizontal (SH) guided waves that are sensitive to cracks oriented either perpendicular or parallel to the wave vector are used to locate welds and to detect cracks. SH waves are excited and received by electromagnetic acoustic transducers (EMATs) using noncontact ultrasonic transduction and pulse-echo mode. A laboratory-scale canister mock-up is fabricated and inspected using the proposed methodology to evaluate the ability of EMATs to excite and receive SH waves and to locate welds. The EMAT's capability to detect notches from various distances is evaluated on a plate containing 25%-through-thickness surface-breaking notches. Based on the results of the distances at which notch reflections are detectable, NDI coverage for spent nuclear fuel storage canisters is determined.

고추력 액체 로켓 엔진용 터보펌프의 회전체동역학 해석 (Rotordynamic Analysis of a High Thrust Liquid Rocket Engine Turbopump)

  • 전성민;곽현덕;윤석환;김진한
    • 한국항공우주학회지
    • /
    • 제36권7호
    • /
    • pp.688-694
    • /
    • 2008
  • 볼 베어링과 펌프 비접촉 실의 동특성을 고려하여 고추력 액체 로켓 엔진용 터보펌프의 회전체동역학 해석이 수행되었다. 회전 고유진동수와 감쇠비를 예측하기 위하여 회전속도에 따른 복소 고유치 해석이 수행되었다. 동기 회전체 질량 불평형 응답과 시간 과도 응답 해석을 통하여 회전체의 임계속도와 불안정 운전 시작 속도가 확인되었다. 수치 해석 결과로부터 후방 베어링 강성이 임계속도와 불안정성 예측에 있어서 가장 중요한 인자로 확인되었는데, 이는 1차 모드가 터빈부 회전축 굽힘 모드인 것에 기인한다. 임계속도에 있어서 펌프 실의 영향은 후방 베어링 강성이 감소할수록 그리고 전방 베어링 강성이 증가할수록 확대되는 것으로 나타났다.