• Title/Summary/Keyword: Non-resonant

Search Result 201, Processing Time 0.025 seconds

Voltage Control of Stand-Alone Inverter for Power Quality Improvement Under Unbalanced and Non-linear Load (불평형 및 비선형부하 시 전력품질 향상을 위한 독립형 인버터의 전압제어 기법)

  • Lee, Wujong;Jo, Jongmin;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.567-575
    • /
    • 2016
  • This paper proposed the voltage control of stand-alone inverter for power quality improvement under unbalanced and non-linear load. The 3-phase DC-AC inverter controls CVCF(Constant Voltage Constant Frequency) and selective harmonic eliminate method in stand-alone mode by PR controller, and the stand-lone inverter supplies stable sinusoidal voltage to balanced, unbalanced and non-linear loads. The total harmonic distortion(THD) of line-to-line load voltage($V_{LL}$) is 1.2% in the balanced load. THD of $V_{LL}$ is reduced from 5.2% to 1.4% and 6.7% to 3.5%, respectively unbalanced and non-linear load. The stand-alone inverter can be supplies sinusoidal balanced voltage to unbalanced load because the voltage unbalanced factor(VUF) of $V_{LL}$ is reduced from 5.2% to 1.4% in the unbalanced load. Feasibility of control method for a stand-alone inverter will be verified through 30kW stand-alone inverter system.

Active Vibration Control Experiment on Cylindrical Shell equipped with MFC Actuators (MFC 작동기를 이용한 실린더 쉘의 능동진동제어 실험)

  • Bae, Byung-Chan;Jung, Moon-San;Kwak, Moon-K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.457-462
    • /
    • 2006
  • This paper is concerned with the active vibration control experiment on cylindrical shell equipped with Macro Fiber Composite(MFC) actuators. The MFC actuators were glued to the cylindrical shell in circumferential directions. To verify the theoretical result, vibration test using impact hammer and accelerometer was carried out. It was found from experiments that theoretical result predicts experimental result to some extent. The positive position feedback controllers were designed and applied to the test article. It was observed that the resonant amplitude of the fundamental mode was reduced by 20dB thus achieving active vibration control. The active vibration control of the response subject to non resonant excitation has been of interest. We developed the combination of the positive position feedback controller which can cope with the fundamental mode and the positive position feedback controller which can counteract the external disturbance with non resonant frequency. It was found from experiments that the hybrid controller can suppress the vibration amplitude successfully.

  • PDF

High Tc Superconducting Microstrip Patch antenna ; Characterization of Superconducting Antenna using Non-Radiating Edge Feeding Technique (고온 초전도 마이크로스트립 패치 안테나; 비방사면 급전방식을 이용한 초전도 안테나 특성)

  • Chung, Dong-Chul;Park, Sung-Jin;Hwang, Jong-Sun;Park, Jong-Kwang;Han, Byoung-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.375-381
    • /
    • 2000
  • In this paper, we described the characterization of High-Tc Superconducting(HTS) microstrip antenna using non-radiating edge feeding technique and reported the microwave properties of HTS antennas with temperature. To do this, we prepared the $YBa_2Cu_3O_{7-x}$ superconducting thin film on MgO substrate using pulse-laser deposition techniques. The HTS microstrip antenna using non-radiating feeding technique was fabricated using chemical wet-etching. Then it was compared with identical antenna patterned with evaporated gold. The diverse measured results have been reported in terms of the input impedance, resonant frequency and return loss. In additional, at around the critical temperature, the effect of kinetic inductance which affect the resonant characteristic of the HTS microstrip antenna was reported.

  • PDF

A Design of ZVS Multi-Resonant Forward Converter for Non-contact Charging (비접촉 충전을 위한 ZVS 다중공진 포워드 컨버터의 설계)

  • Kim, Young-Gil;Na, Hee-Su;Kim, Jin-Woo;Lee, Sung-Paik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1300-1302
    • /
    • 2000
  • In the charge system, a contact type-convenient-charging method is insufficient because of the contact failure around moist environment and troublesome question to put in and pull out. For the solution of this problem, an electromagnetically coupled non-contact charger for the rechargeable cell is proposed using ZVS multi-resonant forward converter. In this paper magnetizing inductance, leakage inductance and coupling coefficient, k are observed. By using the obserbed value, the proposed circuit is simulated by the PSPICE and implemented and the peak voltage of switch and output power are measured.

  • PDF

A Study on the Improvement of Performance and Stability of Induction Heating System (유도 가열 시스템의 성능과 안정성 향상에 관한 연구)

  • Gwon, Yeong-Seop;Yu, Sang-Bong;Hyeon, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.417-425
    • /
    • 1999
  • This paper presents an effective control scheme with the voltage-fed half-bridge series resonant inverter for induction heating system, which is based upon a load-adaptive tuned frequency tracking control strategy using PLL(Phase Locked Loop) and its peripheral control circuits. The proposed control strategy ensures a stable operation characteristics of overall inverter system and ZVS(Zero Voltage Switching) irrespective of sensitive load parameter variations, specially in the non-magnetic materials as well as power regulation. The detail operation principle and the characteristics of inverter system with the proposed control scheme are described and its validity is verified by the simulation and the experimental results for a prototype induction cooking system rated at 1.2kW.

  • PDF

Treatment of non-resonant spatial self-shielding effect of double heterogeneous region

  • Tae Young Han;Hyun Chul Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.749-755
    • /
    • 2023
  • A new approximation method was proposed for treating the non-resonant spatial self-shielding effects of double heterogeneous region such as the double heterogeneous effect of VHTR fuel compact in the thermal energy range and that of BP compact with BISO. The method was developed based on the effective homogenization method and a spherical unit cell model with explicit coated layers and a matrix layer. The self-shielding factor was derived from the relation between the collision probabilities for a double heterogeneous compact and the effective cross section for the homogenized compact. First, the collision probabilities and transmission probabilities for all layers of the spherical model were calculated using conventional collision probability solver. Then, the effective cross section for the homogenized sphere cell representing the homogenized compact was obtained from the transmission probability calculated using the probability density function of a chord length. The verification calculations revealed that the proposed method can predict the self-shielding factor with a maximum error of 2.3% and the double heterogeneous effect with a maximum error of 200 pcm in the typical VHTR problems with various packing fractions and BP compact sizes.

A Study on Fractal Antenna Design and Fabrication for Multi-Band Applications (다중대역용 프랙탈 안테나의 설계 및 제작에 관한 연구)

  • Kim, Kab-Ki
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.5
    • /
    • pp.81-86
    • /
    • 2011
  • In this paper, fractal microstrip patch antenna in a semicircle, by designing a multi-resonant antenna was improved by bandwidth issues, including the IEEE 802.11 wireless LAN and IEEE802.16e-band mobile WiMax specification both of which can contain non-directional antenna design and measured characteristics of the antenna for multi-resonant resonant frequency, impedance matching, radiation pattern, brilliantly polarity and multiple independent frequencies that can be controlled to meet the three semicircular wireless communications by inserting fractal patch antenna was designed.

Resonant Parametric Perturbation Method to Control Chaos in Current Mode Controlled DC-DC Buck-Boost Converter

  • Kavitha, Anbukumar;Uma, Govindarajan
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.171-178
    • /
    • 2010
  • Resonant parametric perturbation (RPP) method is an effective non-feedback method for controlling chaos. In this paper, the above method is applied for the current programmed buck-boost dc-dc converter which exhibits chaotic for wide parameter variations. The different possible operating regimes leading to chaotic operation of the current mode controlled buck-boost converter is discussed and the control of chaos by RPP method is demonstrated through computer simulations and experimental studies. The converter is stabilized to period 1 operation practically.

LLC Resonant and Synchronous Buck Converter Based High Efficiency Battery Charger for Energy Storage Systems (에너지 저장 시스템을 위한 LLC/동기 벅컨버터 기반 고효율 배터리 충방전기 설계)

  • Lee, Taeyeong;Lee, Il-Oun;Cho, Younghoon;Kim, Hangoo;Cho, Junseok;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.15-16
    • /
    • 2016
  • This paper proposes an isolated DCDC converter that consists of unregulated LLC resonant converter and non-isolated synchronous buck converter for battery charger of energy storage systems application. The unregulated converter operates as transformer with fixed duty ratio and switching frequency. The synchronous buck converter is installed in the output of the LLC resonant converter. And the converter charges and discharges the battery by controlling a current of battery. The proposed converter can get the high efficiency by separating function. This paper explains design of an unregulated converter and synchronous converter.

  • PDF

PRACTICAL EVALUATIONS OF PARASITIC RESONANT PWM DC-DC CONVERTERS FOR HIGH-POWER MEDICAL USE

  • H. Takano;J. Takahashi;Sun, J.M.;L... Gamage;M. Nakaoka
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.701-708
    • /
    • 1998
  • This paper presents a novel non-resonant PWM DC-DC converter for X-ray high-voltage power generator using the parasitic impedances of the high-voltage high-frequency link transformer with its output high-voltage control scheme and steady-state characteristics compared to the conventional series-parallel resonant DC-DC converter. The key point of this approach is to evaluate effectiveness of reduction of the turn ratio of the high-voltage high-frequency transformer on improvements in power conversion efficiency and the power factor applying a boost AC-DC converter as DC voltage source, especially in the long exposure term and light output load ranges.

  • PDF