DOI QR코드

DOI QR Code

Resonant Parametric Perturbation Method to Control Chaos in Current Mode Controlled DC-DC Buck-Boost Converter

  • Kavitha, Anbukumar (Dept. of Electrical and Electronic Engineering, College of Engineering Guindy, Anna University) ;
  • Uma, Govindarajan (Dept. of Electrical and Electronic Engineering, College of Engineering Guindy, Anna University)
  • Published : 2010.03.01

Abstract

Resonant parametric perturbation (RPP) method is an effective non-feedback method for controlling chaos. In this paper, the above method is applied for the current programmed buck-boost dc-dc converter which exhibits chaotic for wide parameter variations. The different possible operating regimes leading to chaotic operation of the current mode controlled buck-boost converter is discussed and the control of chaos by RPP method is demonstrated through computer simulations and experimental studies. The converter is stabilized to period 1 operation practically.

Keywords

References

  1. D.C.Hamill, "Power Electronics: A field rich in nonlinear dynamics," International workshop on Nonlinear Dynamics Electron.Syst., Ireland, July 1995.
  2. J. Deane, D. Hamill, "Instability, Sub harmonics and Chaos in power electronic systems," IEEE Transactions on Power Electronics, 260-267, 1990.
  3. S.Banerjee,G.C.Verghese, "Nonlinear phenomena in power electronics: Attractors," bifurcations, chaos and nonlinear control, IEEE press, 2001.
  4. Y.Zhou, C.K.Tse, S.S.Qiu, F.C.M. Lau, "Applying resonant parametric perturbation to control chaos in the buck dc/dc converter with phase shift and frequency mismatch considerations," International Journal of Bifurcation and Chaos, pp.3459-3471, 2003.
  5. G.Cicogna.,"Changing the threshold of chaos by resonant parametric Modulation," Nuova Cim, pp.813-815, 1990. https://doi.org/10.1007/BF02742805
  6. R.Lima, M.Pettini, "Suppression of chaos by resonant parametric perturbations," Physics Review, A41, pp. 726-733, 1990.
  7. J.Wu, M.Liu, P.Yang, "Study of bifurcations and chaos in current mode controlled buck-boost dc-dc converter", Control theory and Applications," pp. 387-394, 2002.
  8. Y.Zhou, H.H.C.Iu, C.K.Tse, J.N.Chen, "Controlling chaos in DC/DC converters using optimal resonant parametric perturbation," IEEE ISCAS'05, Vol.3, pp. 2481-2484, 2005.
  9. Kavitha A. and Uma G., "Analysis and Control of Chaos in Current Controlled Buck Boost DC-DC Converter by Resonant Parametric Perturbation Method," Proceedings of Applied Power Electronics Conference and Exposition APEC'08, 24-28th February, Austin, Texas University, USA, pp.323-327, 2008.

Cited by

  1. Plasma Display Panel Driver With Dissymmetric Energy Transfer Speed for High Efficiency and Fast Voltage Transition vol.8, pp.12, 2012, https://doi.org/10.1109/JDT.2012.2219037
  2. Neutral Point Clamped Inverter Based PDP Driver vol.9, pp.12, 2013, https://doi.org/10.1109/JDT.2013.2274096
  3. CHAOTIC DYNAMICS OF VOLTAGE-MODE CONTROLLED BUCK CONVERTER WITH PERIODIC INTERFERENCE SIGNALS vol.23, pp.06, 2013, https://doi.org/10.1142/S0218127413500995
  4. Control-to-output Transfer Function of the Open-loop Step-up Converter in CCM Operation vol.9, pp.5, 2014, https://doi.org/10.5370/JEET.2014.9.5.1562
  5. Comparative loss analysis and efficiency performance of resonance-based PDP sustain drivers vol.103, pp.1, 2016, https://doi.org/10.1080/00207217.2015.1028478
  6. Analysis and mitigation of EMI in DC–DC converters using QR interaction vol.11, pp.4, 2017, https://doi.org/10.1049/iet-cds.2016.0288
  7. Resonant Energy-Recovery Circuit With Asymmetric Voltage Excitation and No Circulating Current for Plasma Display Panel vol.8, pp.10, 2012, https://doi.org/10.1109/JDT.2012.2203331
  8. Adaptive control of bifurcation and chaos in a time-delayed system vol.22, pp.3, 2013, https://doi.org/10.1088/1674-1056/22/3/030508
  9. Non-linear intermittent instabilities and their control in an interleaved DC/DC converter vol.7, pp.5, 2014, https://doi.org/10.1049/iet-pel.2013.0313
  10. Control Strategy for Buck DC/DC Converter Based on Two-dimensional Hybrid Cloud Model vol.11, pp.6, 2016, https://doi.org/10.5370/JEET.2016.11.6.1684
  11. Effect of Circuit Parameters on Stability of Voltage-fed Buck-Boost Converter in Discontinuous Conduction Mode vol.9, pp.4, 2014, https://doi.org/10.5370/JEET.2014.9.4.1283
  12. Simplified sustain driver with low-voltage semiconductor devices and low-voltage power supply for AC plasma display panel vol.57, pp.2, 2011, https://doi.org/10.1109/TCE.2011.5955159
  13. Cost-Effective Driving System Based on Switching Scan IC for AC Plasma Display Panels vol.8, pp.9, 2012, https://doi.org/10.1109/JDT.2012.2188375
  14. Time Domain Based Digital Controller for Buck-Boost Converter vol.9, pp.5, 2014, https://doi.org/10.5370/JEET.2014.9.5.1551
  15. Analysis on the effect of external spurious signals in an H-bridge inverter vol.11, pp.11, 2018, https://doi.org/10.1049/iet-pel.2017.0689
  16. Analysis and mitigation of conducted EMI in current mode controlled DC–DC converters pp.1755-4543, 2018, https://doi.org/10.1049/iet-pel.2018.5322