• 제목/요약/키워드: Non-precious metal

검색결과 77건 처리시간 0.029초

-금속(金屬) 표면처리방법(表面處理方法)에 따른 비귀금속합금(非貴金屬合金)과 도재(陶材)와의 결합강도(結合强度)에 관(關)한 실험적(實驗的) 연구(硏究)- (An Experimental study on the bond strength according to the surface treatment of metal alloy for porcelain fused metal crown)

  • 정인성
    • 대한치과기공학회지
    • /
    • 제11권1호
    • /
    • pp.83-88
    • /
    • 1989
  • This investigation was performed to evaluate the effect of four different preteatment techniques on the bond strength of porcelain to non-precious metal alloy. Samples of total of 40 were divided into 4 groups according to the 4 variables which included the 50$\mu$alumina oxide air abrasion, method, the as retention bead method, the L-retention bead method, the Etching method. The completed metal-porcelain samples were compressed in Instron loading machine until gross fracture occured to examine the effect of the complex variables on the bond strength of porcelain to non precious metal alloy. The result obtained were as follows : 1. The difference of bond strength according to four different pretreatment techniques was statistically significant(p<0.01). 2. The difference of bond strength between the ss-retention bead method and the L-retention bead method was not significant statistically(p>0.05) 3. The difference of bond strength between the retention bead method and the etching method was statistically significant(p<0.01). 4. The difference of bond strength between the retention bead method and the 50$\mu$alumina oxide air abrasion method was statistically significant(p<0.01). 5. The difference of bond strength between the etching method and the 50$\mu$alumina oxide air abrasion method was statistically significant(p<0.01).

  • PDF

치과용 임플란트 적용 비귀금속 코어와 관련된 전조골세포의 변화 (Changes in pre-osteoblast cells associated with non-precious metal cores with dental implants: Pilot test)

  • 박정현;강신영;김종우;김장주;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제40권2호
    • /
    • pp.63-69
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the non-precious metal core materials used in the dental laboratory to fabricate the implant superstructure by CAD / CAM method. And to observe and compare the morphology and distribution of the osteoblasts in relation to implant osseointegration. Methods: In this study, the mandibular right first molar tooth model was selected as an international standard to produce a single core. Using this model, the impression was made with the silicone rubber, the tooth model was scanned, and a single core was designed and 5-axis milling was performed. The materials used were Cobalt-Chromium and Nickel-Chromium, and the cores for dental implant top structures were fabricated according to the procedures of the dental labs. After the fabrication, the marginal area of the core was separated and cell culture experiment was performed. The osteoblast cells used MC3T3-E1, which is currently widely used. For morphological analysis of osteoblasts, cells were posttreated and observed using CLSM (Confocal Laser Scanning Microscope) and compared. Results: The cell adhesion behavior of the specimen surface measured by CLSM was uniformly distributed in specimen A (Cobalt-Chromium) than in specimen B (Nickel-Chromium). The distribution and changes of the cells were different in the two specimens. Conclusion : It is possible to confirm that specimen A (Cobalt-Chromium) is suitable for the living body through adhesion and proliferation of osteoblasts related to implant osseointegration in the non-precious metal superstructure used after implantation. It is considered that it is preferable to use Co-Cr when fabricating the superstructure.

Optimal Metal Dose of Alternative Cathode Catalyst Considering Organic Substances in Single Chamber Microbial Fuel Cells

  • Nam, Joo-Youn;Moon, Chungman;Jeong, Emma;Lee, Won-Tae;Shin, Hang-Sik;Kim, Hyun-Woo
    • Environmental Engineering Research
    • /
    • 제18권3호
    • /
    • pp.145-150
    • /
    • 2013
  • Optimal preparation guidelines of a cathode catalyst layer by non-precious metal catalysts were evaluated based on electrochemical performance in single-chamber microbial fuel cells (MFCs). Experiments for catalyst loading rate revealed that iron(II) phthalocyanine (FePc) can be a promising alternative, comparable to platinum (Pt) and cobalt tetramethoxyphenylporphyrin (CoTMPP), including effects of substrate concentration. Results showed that using an optimal FePc loading of $1mg/cm^2$ was equivalent to a Pt loading of $0.35mg/cm^2$ on the basis of maximum power density. Given higher loading rates or substrate concentrations, FePc proved to be a better alternative for Pt than CoTMPP. Under the optimal loading rate, it was further revealed that 40 wt% of FePc to carbon support allowed for the best power generation. These results suggest that proper control of the non-precious metal catalyst layer and substrate concentration are highly interrelated, and reveal how those combinations promote the economic power generation of single-chamber MFCs.

치아에 잔존하는 치과재료의 성분분석을 통한 개인식별에의 응용 (Analysis of Residual Dental Materials Existing on the Teeth and Its Application to Individual Identification)

  • 윤중교;최종훈;김종열
    • Journal of Oral Medicine and Pain
    • /
    • 제23권2호
    • /
    • pp.193-209
    • /
    • 1998
  • In identifying bodies that are severely decayed or damaged, methods using fingerprints and various biochemical tests are known to have its limits. To overcome this, forensic odontological method which is based on the analysis of the cranium, tooth and dental restoration is used to enhance the accuracey of individual identification. For this reason, I have come to analysis of the dental materials that exists between the teeth that is perceived to have been previously restored and the one adjacent to it. By analyzing the constituents of gold crown-restored, non-precious metal-restored, gold inlay-restored and amalgam -restored teeth, and adjacent teeth using EDX(energy dispersive X-ray microanalysis) which was invented to analyze very small amount of elements, the nature of the restoration could be predicted and the results obtained were as follows. 1. Some of constitute of gold alloy was extracted from residual cement of gold crown restoration, but that was not extracted from the restored tooth and the one adjacent to it. 2. Some of constituents of non-precious metal alloy was extracted both in the residual cement on the tooth with no-precious metal restoration and in the tooth with the restoration itself. However, none of its constituents were found in the tooth adjacent to it. 3. Some of constituents of gold alloy were found in the residual cement of gold inlay, but they were not found in the restored tooth and the adjacent tooth. 4. Some of constituents of amalgam alloy were found both in tooth restored with amalgam and in the adjacent tooth. From the results obtained above, it is possible to utilize the data obtained from analyizing residual dental materials in a more effective way. This data compensates for the lost data due to any harm done to the restorations prior to individual identification and further enhances the accuracy. Therefore, it could be concluded that this process of analyzing residual dental materials could be beneficial to individual identification in the area of forensic odontoldogy.

  • PDF

베릴륨함유 치과 주조용 비귀금속 합금의 젖산용액에 의한 금속 노출수준 평가 (Evaluation of a metal level in non-precious metal alloys dental casting having beryllium by lactic acid Solution)

  • 박수철;장은진;한석윤
    • 대한치과기공학회지
    • /
    • 제33권2호
    • /
    • pp.121-128
    • /
    • 2011
  • Purpose: The purpose of this study is to investigate the level of each metal in non-precious metal alloys dental casting, still used even banned for use and trade by the law, for oral health. Methods: Two kinds of metal alloys were analyzed. One was Ticonium 100 for removable prosthesis and the other was Rexillium V for dental porcelain. Two samples of each metal alloy were made in 0.5g, 1.0g, and 1.5g. Total number of samples were 12. Two kinds of lactic acid Solution, pH7 and pH4.6, were injected into each samples. After injection, each samples had been for 21days ${\pm}$ 1 hour in the water tank of which temperature was $37^{\circ}C$. The level of metal was measured in each sample by inductively couplled plasma-atomic emission spectrometer. Results: In both metal alloys, metals, chrome, nickel, beryllium, and molybdenum, were founded. In Ticonium 1000, the highest level of nickel was 2.531ppm in 1.5g pH4.6 sample while the highest level of nickel was 4.062ppm in 1.5g pH4.6 sample of Rexillium V. In chemical composition of these methal alloys, chrome(14~17%) was much more than beryllium(1.95~1.99%) and molybdenum(5.0~9.0%) but berllium and molybdenum were founded more than chrome in samples. Therefore, chrome showed better anti-corrosion than other metal alloys. In both metal alloys, more metals were founded in higher pH level and more mass. Levels of chrome was significantly different in samples of both metal alloys in each pH level(p<0.05). Levels of nickels was significantly different in samples of both metal alloys in each pH level(p<0.05). Conclusion: For oral health, further studies are needed in nickel-chrome metal alloy and cobalt metal alloy of non-beryllium in addittion to beryllium metal alloy and also long-term studies needed in various period and other non-percious metal alloys for dental casting.

이온선 혼합법이 도재와 금속의 결합에 미치는 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECTS OF ION BEAM HIKING ON CERAMO-METAL BONDING)

  • 홍준표;우이형;최부병
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.245-265
    • /
    • 1991
  • The purpose of this study was to observe the changes of the elemental transmission and bond strength between the metal and porcelain according to various kinds of ion beam mixing method. ion beam mixing of $meta1/SiO_2$ (silica), $meta1/Al_2O_3$(alumina) interfaces causes reactions when the $Ar^+$ was implanted into bilayer thin films using a 100KeV accelerator which was designed and constructed for this study. A vacuum evaporator used in the $10^{-5}-10^{-6}$ Torr vacuum states for the evaporation. For this study, three kinds of porcelain metal selected, -precious, semiprecious, and non-precious. Silica and alumina were deposited to the metal by the vacuum evaporator, separately. One group was treated by two kinds of dose of the ion beam mixing $(1\times10^{16}ions/cm^2,\;5\times10^{15}ions/cm^2)$, and the other group was not mixed, and analyzed the effects of ion beam mixing. The analyses of bond strength, elemental transmissions were performed by the electron spectroscopy of chemical analysis (ESCA), light and scanning electron microscope, scratch test, and micro Vickers hardness tests. The finding led to the following conclusions. 1. In the scanning electron and light microscopic views, ion beam mixed specimens showed the ion beam mixed indentation. 2. In the micro Vickers hardness and scratch tests, ion beam mixed specimens showed higher strength than that of non mixed specimens, however, nonprecious metal showed a little change in the bond strength between mixed and non mixed specimens. 3. In the scratch test, ion beam mixed specimens showed higher shear strength than that of non treated specimens at the precious and semiprecious groups. 4. In the ESCA analysis, Au-O and Au-Si compounds were formed and transmission of the Au peak was found ion beam mixed $SiO_2/Au$ specimen, simultaneously, in the higher and lower bonded areas, and ion beam mixed $SiO_2/Ni-Cr$ specimen, oxygen, that was transmitted from $SiO_2\;to\;SiO_2/Ni-Cr$ interface combined with 12% of Ni at the interface.

  • PDF

비귀금속 합금에 적용한 Au Based Bonding Agent가 금속-도재 결합에 미치는 영향 (The Effect of a Au Based Bonding Agent Coating on Non-Precious Metals-Ceramic Bond Strength)

  • 이정환;안재석
    • 치위생과학회지
    • /
    • 제9권4호
    • /
    • pp.405-412
    • /
    • 2009
  • 본 연구는 도재소부용 비귀금속에 Au 코팅 층을 형성하고, Au 코팅 층이 금속-도재의 결합력에 미치는 영향을 알아보고자 2출 굴곡 시험 후에 SEM/EDS 방법으로 조사하여 비교하였다. 1. Ni-Cr ally 군과 Co-Cr alloy 군, 그리고 Ti 군의 절단면 시편의 전자현미경 사진에서 Au 코팅 층은 산화층의 확산을 제어하는 것으로 관찰되었다. 2. 2축 굴곡 시험 후에 EDS 분석 결과 Ni-Cr alloy 군과 Co-Cr alloy 군에서 Si 함량은 Au 코팅 층을 형성한 시편에서 약간 감소하였고, 결합실패의 형태는 cohesive failure와 adhesive failure가 혼재된 양상으로 관찰되었다. 3. Ni-Cr alloy 군과 Co-Cr alloy 군에서 Au 코팅 층은 도재-금속 결합력에 미치는 영향은 미미하였다. 4. Ti 군의 결합실패 형태는 Ni-Cr alloy 군과 Co-Cr alloy 군에 비해서 adhesive failure 양상이 두드러지게 관찰되었고, Au 코팅 층은 도재-금속 결합력에 영향을 미치지 않았다. 이상의 결과 비귀금속에 적용한 Au 코팅은 산화층의 확산을 제어 하는 것으로 관찰 되었으나, 금속-도재 간의 결합력 증징에 미치는 효과는 미미하였다. Au 코팅을 이용하여 금속-도재 간의 결합력 증진을 위해서는 많은 연구가 지속되어야 할 것으로 사료된다.

  • PDF

Electrocatalysis of Selective Chlorine Evolution Reaction: Fundamental Understanding and Catalyst Design

  • Taejung Lim;Jinjong Kim;Sang Hoon Joo
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권2호
    • /
    • pp.105-119
    • /
    • 2023
  • The electrochemical chlorine evolution reaction (CER) is an important electrochemical reaction and has been widely used in chlor-alkali electrolysis, on-site generation of ClO-, and Cl2-mediated electrosynthesis. Although precious metal-based mixed metal oxides (MMOs) have been used as CER catalysts for more than half a century, they intrinsically suffer from a selectivity problem between the CER and parasitic oxygen evolution reaction (OER). Hence, the design of selective CER electrocatalysts is critically important. In this review, we provide an overview of the fundamental issues related to the electrocatalysis of the CER and design strategies for selective CER electrocatalysts. We present experimental and theoretical methods for assessing the active sites of MMO catalysts and the origin of the scaling relationship between the CER and the OER. We discuss kinetic analysis methods to understand the kinetics and mechanisms of CER. Next, we summarize the design strategies for new CER electrocatalysts that can enhance the reactivity of MMO-based catalysts and overcome their scaling relationship, which include the doping of MMO catalysts with foreign metals and the development of non-precious metal-based catalysts and atomically dispersed metal catalysts.

VENT가 도재전장 주조관용 비귀금속 합금의 주조성에 미치는 영향에 관한 연구 (THE EFFECT OF THE VENT ON THE CASTABILITY OF A NONPRECIOUS ALLOY USED FOR PORCELAIN-FUSED-TO-METAL CROWN)

  • 이진걸;장완식
    • 대한치과보철학회지
    • /
    • 제23권1호
    • /
    • pp.145-154
    • /
    • 1985
  • To study the effect of the vent and dense surface of the phophate-bonded investment on the castability of a non-precious alloy used in PFM restoration, one-ended polypropylene straw patterns of 0.15mm thick, 5mm radius. 10mm-high were cast with Vera Bond. The following results were obtained. 1. Thin patterns could be cast completely with a non-precious alloy. 2. No difference in the castability was found among the patterns with vent, chill vent and with out vent. 3. Dense surface of the phosphate-bonded investment had no effect on the cast ability of a nonprecious alloy.

  • PDF

전도성 고분자를 이용한 연료전지용 비백금 촉매의 특성화 정량 (Characterization of Non-precious Metal for Fuel Cell Catalyst with Conducting Polymer)

  • 김현종;이효준;안지은;김한성;이호년
    • 응용화학
    • /
    • 제15권2호
    • /
    • pp.137-140
    • /
    • 2011
  • Excellent active and stable platinum catalyst fuel cells currently being used as a catalyst. However, because of the high price of platinum catalyst, such as non-precious catalyst has been studied by a variety of fuel cell catalysts. In this study, Co/ PANi//CNT composite catalyst after synthesis through various heating process was to increase the activity of the catalyst. At 700℃ showed the best catalytic activity, using a composite catalyst was to be used as cathode electrodes in fuel cell.