• 제목/요약/키워드: Non-power system

검색결과 1,735건 처리시간 0.026초

Resource allocation for Millimeter Wave mMIMO-NOMA System with IRS

  • Bing Ning;Shuang Li;Xinli Wu;Wanming Hao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제18권7호
    • /
    • pp.2047-2066
    • /
    • 2024
  • In order to improve the coverage and achieve massive spectrum access, non-orthogonal multiple access (NOMA) technology is applied in millimeter wave massive multiple-input multiple-output (mMIMO) communication network. However, the power assumption of active sensors greatly limits its wide applications. Recently, Intelligent Reconfigurable Surface (IRS) technology has received wide attention due to its ability to reduce power consumption and achieve passive transmission. In this paper, spectral efficiency maximum problem in the millimeter wave mMIMO-NOMA system with IRS is considered. The sparse RF chain antenna structure is designed at the base station based on continuous phase modulation. Furthermore, a joint optimization problem for power allocation, power splitting, analog precoding and IRS reconfigurable matrices are constructed, which aim to achieve the maximum spectral efficiency of the system under the constraints of user's quality of service, minimum energy harvesting and total transmit power. A three-stage iterative algorithm is proposed to solve the above mentioned non-convex optimization problems. We obtain the local optimal solution by fixing some optimization parameters firstly, then introduce the relaxation variables to realize the global optimal solution. Simulation results show that the spectral efficiency of the proposed scheme is superior compared to the conventional system with phase shifter modulation. It is also demonstrated that IRS can effectively assist mmWave communication and improve the system spectral efficiency.

Performance of ZF Precoder in Downlink Massive MIMO with Non-Uniform User Distribution

  • Kong, Chuili;Zhong, Caijun;Zhang, Zhaoyang
    • Journal of Communications and Networks
    • /
    • 제18권5호
    • /
    • pp.688-698
    • /
    • 2016
  • In this paper, we investigate the achievable sum rate and energy efficiency of downlink massive multiple-input multiple-output antenna systems with zero-forcing precoding, by taking into account the randomness of user locations. Specifically, we propose two types of non-uniform user distributions, namely, center-intensive user distribution and edge-intensive user distribution. Based on these user distributions, we derive novel tight lower and upper bounds on the average sum rate. In addition, the impact of user distributions on the optimal number of users maximizing the sum rate is characterized. Moreover, by adopting a realistic power consumption model which accounts for the transmit power, circuit power and signal processing power, the energy efficiency of the system is studied. In particular, closed-form solutions for the key system parameters, such as the number of antennas and the optimal transmit signal-to-noise ratio maximizing the energy efficiency, are obtained. The findings of the paper suggest that user distribution has a significant impact on the system performance: for instance, the highest average sum rate is achieved with the center-intensive user distribution, while the lowest average sum rate is obtained with the edge-intensive user distribution. Also, more users can be served with the center-intensive user distribution.

워킹코일 온도 및 제어 속응성을 고려한 All-Metal Domestic Induction Heating 제어 시스템 설계 (Design of Control System for All-Metal Domestic Induction Heating Considering Temperature and Quick-Response)

  • 박상민;장은수;주동명;이병국
    • 전력전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.199-207
    • /
    • 2018
  • In this paper, an all-metal domestic induction heating (IH) system that can quickly identify ferromagnetic and non-ferromagnetic pots considering temperature changes in the working coil is designed. Load modeling is performed after analyzing the parameters of the pot material and the central misalignment of the working coil. To improve the performance and stability of the all-metal IH cooking heater, a power curve-fitting model is used to design a control system that quickly responds to load parameter fluctuations. In addition, a power control algorithm is established to compensate for the reference value by reflecting the increase in working coil temperature during heating of the non-ferromagnetic pot. The validity of the proposed control algorithm for the all-metal IH is verified by experiments using a 3.2 kW all-metal IH cooking heater.

에너지저장장치 도입 시 비예측 알고리즘의 경제성 분석에 관한 연구 (Study on the Economic Analysis for Non-Prediction Algorithm with the Energy Storage System)

  • 홍종석;강병욱;채희석;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권5호
    • /
    • pp.94-99
    • /
    • 2015
  • Prediction algorithm of the energy storage system in accordance with the load pattern can cause economic loss in case of a failure prediction. In addition, algorithm that uses TOU(Time of Use) based on the revelation by the power electric charge which covers most simply is an inefficient operation because it is only for the purpose of reducing the peak power. In this paper, we introduced a non-prediction algorithm with a conventional TOU in order to solve this problem operating the energy storage system economic and efficient.

비선형 부하를 위한 복합전력필터 (Hybrid Active Filter System for High Power Non-linear Loads)

  • 강민수;노윤성;김수곤;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.182-185
    • /
    • 2003
  • Proposed Hybrid System is composed of phase leading capacitor banks, LC passive filters and active power filter. The passive power filter in parallel connection eliminate the 5th and 7th harmonics. The Variable capacitor banks correct the most of power factor, and the active power filter takes charge of remainder,

  • PDF

Substation Reliability Assessment Considering Non-Exponential Distributions And Restorative Actions

  • Kim, Gwang-Won;Lee, Kwang Y.
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권3호
    • /
    • pp.155-160
    • /
    • 2003
  • Reliability assessment of power systems has been an important topic for the past several decades. It is becoming even more important nowadays as the power market moves toward a new competitive environment. This paper deals with two topics on reliability assessment. The first is how to select probability distributions and determine their parameters to model the probabilistic events in a power system. The second is how to consider restorative actions in the assessment, which directly influence reliability indices. This paper proposes simple but convincing alternative solutions on the two topics. In the case study, this paper shows the influences of the probability distributions that are used in power system modeling.

Design of safety critical and control systems of Nuclear Power Plants using Petri nets

  • Singh, Pooja;Singh, Lalit Kumar
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1289-1296
    • /
    • 2019
  • Non-functional requirements plays a critical role in designing variety of applications domain ranges from safety-critical systems to simple gaming applications. Performance is one of the crucial non-functional requirement, especially in control and safety systems, that validates the design. System risk can be quantified as a product of probability of system failure and severity of its impact. In this paper, we devise a technique to do the performance analysis of safety critical and control systems and to estimate performance based risk factor. The technique elaborates Petri nets to estimate performability to ensure system dependability requirements. We illustrate the technique on a case study of Nuclear Power Plant system. The technique has been validated on 17 safety critical and control systems of Nuclear Power Plant.

Performance Improvement of the Linear BLDC Generator in a NASA Deep Space Explorer

  • Lee, Hyung-Woo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.108-113
    • /
    • 2004
  • This paper presents methods to improve performance of the power supply system in a NASA deep space explorer. In the Stirling engine driven reciprocating Brushless DC (BLDC) generator, the accurate position information of the prime mover is important to diagnose the performance of the engine and prevent distortion of the output power. Since sensors to detect the position are fragile and unreliable, and conventional sensorless techniques have drawbacks in the low speed region, a novel sensorless position detection technique for the prime mover has been proposed and verified. Another major issue of the generator for the spacecraft is power density maximization. The mass of the power system is important to the mass of the satellite. Therefore, the components of the spacecraft should be lightweight. Conventional rectification methods cannot achieve the maximum power possible due to non-optimal current waveforms. The optimal current waveform for maximizing power density and minimizing machine size and weight in a nonsinusoidal power supply system has been derived, incorporated in a control system, and verified by simulation work.

대릉(大陵)(PC7) 침자가 뇌파에 미치는 영향 (The Effect of Acupuncture at PC7(Daereung) on EEG in Normal Human Subject)

  • 박철진;이상룡
    • Korean Journal of Acupuncture
    • /
    • 제27권2호
    • /
    • pp.141-157
    • /
    • 2010
  • Objectives : The aim of this study is to examine the effects of acupuncture at PC7(Daereung) on normal human EEG using power spectral analysis. Methods : EEG power spectrum exhibits site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 30 subjects (16 males and 14 females; averaged age = 23.4 years) were engaged with thirty channel EEG study. Results : In $\alpha$(alpha) band, the power values at Fp1, Fp2, F7, F8 channels(p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel(p<0.05) during non-acupoint treatment was significantly decreased. In $\beta$(beta) band, the power values at Fp1, Fp2 channels(p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel(p<0.05) during non-acupoint treatment was significantly decreased and at F8, TCP2 channels(p<0.05) during non-acupoint treatment were increased. In $\theta$(theta) band, the power values at Fp1, Fp2, F7, F8 channels(p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel(p<0.05) during non-acupoint treatment was significantly decreased. In $\delta$(delta) band, the power values at Fp1, Fp2, F7, Fz, F8 channels (p<0.05) during PC7 treatment were significantly decreased. But, the power values at Fz channel (p<0.05) during non-acupoint treatment was significantly decreased. $\alpha/\beta$ values during PC7 treatment were decreased. $\beta/\theta$ values during PC7 treatment were decreased. Conclusion : These results suggest that acupuncture at PC7 induce the change on $\alpha$(alpha), $\beta$(beta), $\theta$ (theta), $\delta$(delta) wave values being decreased and and bothe $\alpha/\beta$ and $\beta/\theta$ values being decreased respectively. This is considered that acupuncture at PC7 affects the activity of cerebral cortex and endocrine system.

저압 모의선로에 소형발전원 연계시 특성 (Connected Characteristics for Small Generation Source of Low Voltage Model Grids)

  • 이상우;강진규;이동하;박태준
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.45-53
    • /
    • 2013
  • In this paper, we analyze the typical phase voltage and line current waveform characteristics of the distribution system with 3 phase small synchronous generation source in case with load and non-load group, in order to investigate the power quality for end load connected of generation source. As demonstrated by our experimental results, the distortion and power quality of phase voltage and line current waveform were relatively good for low voltage 3 phase model grids connected of 3 phase small synchronous generation source in case with non-load group. However, distortion and power quality of voltage and current waveform was poor for low voltage 3 phase model grids connected to 3 phase small synchronous generation source in the load group with some phase voltage and frequency difference. From the above results, we conclude that the phase voltage and frequency of 3 phase generation source must be identical to that of distribution system source to maximize the power quality. Also, special attention is required in case of having load group or non-load group to 3 phase generation source.