• 제목/요약/키워드: Non-normal Distribution

검색결과 380건 처리시간 0.023초

초전도 선재 조합에 따른 비대칭 무유도성 코일의 교류 손실 특성 연구 (A Study on AC loss Characteristics of Asymmetric non-inductive coils with Combination of Superconducting wires)

  • 김진섭;황영진;나진배;최석진;김영재;이지호;이우승;장기성;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.17-21
    • /
    • 2011
  • A hybrid superconducting fault current limiter (SFCL) with fast switch had been previously suggested by our research group. To make a hybrid SFCL, different superconducting wires were wound two pancake coils so that two pancake coils had asymmetric configuration. The impedance of the asymmetric non-inductive coils are zero with applied normal current. However during the fault. currents were distributed unequally into the two pancake coils because each superconducting wires have different electrical characteristics. This unequal distribution of current causes effective magnetic flux which generate repulsive force. Fast switch was thus opened by the force applied to the aluminum plate which consists of SFCL. In this paper, the AC loss characteristics of the asymmetric non-inductive coils with combinations of superconducting wires were studied and calculated by related experiments and finite element method (FEM) simulation. From these results, we suggested the appropriate combination of two superconducting wires to be used for the asymmetric non-inductive coils.

타입에 따른 무유도 권선형 코일의 한류 특성연구 및 자장해석 (A study on the current limiting characteristics and magnetic analysis of the non-inductively wound coil)

  • 장재영;박동근;장기성;나진배;김원철;정윤도;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권1호
    • /
    • pp.25-29
    • /
    • 2009
  • To reduce the power loss in normal state, non-inductively wound high temperature superconducting (HTS) coils are used for fault current limiter (FCL) application. Non-inductively wound coils can be classified into two types: solenoid type and pancake type. These two types have different electrical and thermal and mechanical characteristics due to their winding structure difference. This paper deals with the current limiting characteristics, magnetic field analysis of the two coils. Simulation using finite element method (FEM) was used to analyze the magnetic field distribution and inductance of the coils. Short circuit test using stabilizer-free coated conductor (CC) was also carried out. We can compare the characteristics of the two types of coil by using the data obtained from simulation and short circuit test. We confirmed the feasibility of FCL application by the analysis about the characteristics of non-inductively wound coil using CC.

전수층 무응답 편향보정 추정법에 관한 연구 (A study on non-response bias adjusted estimation for take-all stratum)

  • 정희영;신기일
    • 응용통계연구
    • /
    • 제33권4호
    • /
    • pp.409-420
    • /
    • 2020
  • 사업체조사에서는 흔히 수정절사법이 사용되며 이 방법을 사용함으로써 표본의 수를 줄이면서도 추정의 정확성을 향상 시킬 수 있다. 그러나 전수층의 무응답률은 크게 높아지고 있으며 예비표본을 이용한 표본대체가 불가능하기 때문에 전수층에서 발생한 무응답은 추정의 정확성을 크게 떨어뜨리고 있다. 특히 무응답이 관심변수에 영향을 받는 경우에는 편향이 발생할 가능성이 매우 높기 때문에 이를 적절히 처리하는 것은 매우 중요하다. 본 연구에서는 전수층에서 발생한 무응답을 적절히 처리하는 방법의 하나로 편향보정 추정법을 제안하였다. 특히 Chung과 Shin(2020)에서 제안한 편향보정 추정량을 전수층 편향보정에 적용하였으며 전수층이라는 특수한 경우에 맞는 새로운 추정 방법을 제안하였다. 또한 모의실험을 통해 제안된 방법의 우수성을 살펴보았으며 실제 자료 분석을 실시하여 본 논문에서 제안한 방법의 우수성을 확인하였다.

수질자료의 추세분석을 위한 비모수적 통계검정에 관한 연구 (A Study of Non-parametric Statistical Tests to Analyze Trend in Water Quality Data)

  • 이상훈
    • 환경영향평가
    • /
    • 제4권2호
    • /
    • pp.93-103
    • /
    • 1995
  • This study was carried out to suggest the best statistical test to analyze the trend in monthly water quality data. Traditional parametric tests such as t-test and regression analysis are based on the assumption that the underlying population has a normal distribution and regression analysis additionally assumes that residual errors are independent. Analyzing 9-years monthly COD data collected at Paldang in Han River, the underlying population was found to be neither normal nor independent. Therefore parametric tests are invalid for trend detection. Four Kinds of nonparametric statistical tests, such as Run Test, Daniel test, Mann-Kendall test, and Time Series Residual Analysis were applied to analyze the trend in the COD data, Daniel test and Mann-Kendall test indicated upward trend in COD data. The best nonparametric test was suggested to be Daniel test, which is simple in computation and easy to understand the intuitive meaning.

  • PDF

Correlation Test by Reduced-Spread of Fuzzy Variance

  • Kang, Man-Ki
    • Communications for Statistical Applications and Methods
    • /
    • 제19권1호
    • /
    • pp.147-155
    • /
    • 2012
  • We propose some properties for a fuzzy correlation test by reduced-spread fuzzy variance for sample fuzzy data. First, we define the condition of fuzzy data for repeatedly observed data or that which includes error term data. By using the average of spreads for fuzzy numbers, we reduce the spread of fuzzy variance and define the agreement index for the degree of acceptance and rejection. Given a non-normal random fuzzy sample, we have bivariate normal distribution by apply Box-Cox power fuzzy transformation and test the fuzzy correlation for independence between the variables provided by the agreement index.

자기연상 다층퍼셉트론의 이상 탐지 성능에 대한 실험 (Experiments on the Novelty Detection Capability of Auto-Associative Multi-Layer Perceptron)

  • 이형주;황병호;조성준
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2002년도 춘계공동학술대회
    • /
    • pp.632-638
    • /
    • 2002
  • In novelty detection, one attempts to discriminate abnormal patterns from normal ones. Novelty detection is quite difficult since, unlike usual two class classification problems, only normal patterns are available for training. Auto-Associative Multi-Layer Perceptron (AAMLP) has been shown to provide a good performance based upon the property that novel patterns usually have larger auto-associative errors. In this paper, we give a mathematical analysis of 2-layer AAMLP's output characteristics and empirical results of 2-layer and 4-layer AAMLPs. Various activation functions such as linear, saturated linear and sigmoid are compared. The 2-layer AAMLPs cannot identify non-linear boundaries while the 4-layer ones can. When the data distribution is multi-modal, then an ensemble of AAMLPs, each of which is trained with pre-clustered data is required. This paper contributes to understanding of AAMLP networks and leads to practical recommendations regarding its use.

  • PDF

Electromagnetic field and initial stress on a porothermoelastic medium

  • Abd-Elaziz, Elsayed M.
    • Structural Engineering and Mechanics
    • /
    • 제78권1호
    • /
    • pp.1-13
    • /
    • 2021
  • In this study, the porothermoelastic problem with the effect of the magnetic field and initial stress was investigated. We applied normal mode analysis to solve the resulting non-dimensional coupled equations. Numerical results for the displacements, temperature distribution, pore pressure, stresses, induced electric field and induced magnetic field distributions are presented graphically and discussed. The medium deformed because of thermal shock and due to the application of the magnetic field, there result an induced magnetic and an induced electric field in the medium. Numerical analyses are given graphically on the square (2D) and cubic (3D) domains to illustrate the effects of the porosity parameter, magnetic field and initial stress parameter on the physical variables.

구조물(構造物)의 신뢰성(信賴性)에 관한 소고(小考) -원형단면의 인장재를 중심으로- (A Study on the Structural Reliability)

  • 손승요
    • 대한토목학회논문집
    • /
    • 제5권2호
    • /
    • pp.51-57
    • /
    • 1985
  • 구조물(構造物)의 설계(設計)는 실제(實際)로 불확실성(不確實性)과 무작위적(無作爲的) 가변성(可變性)을 갖는 양(量)들(강도(强度), 칫수, 荷重)에 대하여 시행(施行)하므로 이들 불확실성(不確實과性)과 무작위적(無作爲的) 가변성(可變性)을을 포함(包)한 구조물(構造物)의 신뢰성(信賴性) 판단(判斷)이 중요(重要)한 의미(意味)를 지니게 된다. 본(本) 연구(硏究)는 이러한 신뢰성(信賴性) 판단(判斷)을 신일계(新一階) 2차(次)모멘트법(法)으로 계산(計算)할 때 가변량(可變量)들의 분포상태(分布狀態)가 달라지거나 구조물(構造物)의 붕괴조건(崩壞條件)이 비선형(非線型)일 때 위 방법(方法)에 의(依)한 신뢰성(信賴性) 판단기준(判斷基準)인 안전지수(安全指數)나 붕괴확율(崩壞確率)에 이들이 미치는 오차(誤差)의 정도(程度)와 계산결과(計算結果)의 안전(安全)/불안전측(不安全側)에 대(對)한 논의(論議)를 단순인장부재(單純引張部材)에 대하여 수치적(數値的) 해석(解析)을 통해 제시하고, 특히 생산공정이나 시공관리와 관련된 재료(材料)의 칫수, 강도(彈度) 그리고 구조물(構造物) 설계(設計)에 빈도(頻度) 사용되는 하중(荷重)의 분포특성(分布特性)에 대한 기초조사가 구조물을 보다 신뢰성있게 설계할 수 있는 바탕이 됨을 지적(指摘)하였다.

  • PDF

절사표본에서 최적 절사점에 관한 연구 (A Study on the Optimal Cut-off Point in the Cut-off Sampling Method)

  • 이상은;조민지;신기일
    • 응용통계연구
    • /
    • 제27권3호
    • /
    • pp.501-512
    • /
    • 2014
  • 상당수의 사업체 조사는 절사표본설계법을 사용하고 있다. 이는 절사표본설계법에서 얻은 전수층이 많은 정보를 포함하고 있어 전체 표본크기를 최소화 할 수 있는 장점이 있기 때문이다. 그러나 최근 전수층에 포함된 사업체들의 무응답률이 높아감에 따라 전수층이 가지고 있는 장점에 한계가 나타나고 있다. 이에 Lee (2011), Shin과 Lee (2013)는 표본설계 단계에서부터 주어진 허용오차를 만족하면서 전수층 규모를 최소화하는 연구를 실시하였다. 본 연구에서는 주어진 허용오차를 만족하고 Hidiroglou (1986)가 제안한 방법으로 산출 된 표본크기를 고정한 상태에서 표본층 분산에 알려진 함수를 적합하여 전수층 크기를 최소화하는 새로운 최적 절사점을 제안하였다. 또한 Hidiroglou (1986)와 Shin과 Lee (2013)가 제안한 절단분포를 이용한 방법과 본 연구에서 제안한 방법을 모의실험과 사례연구를 통해 비교하였다.

배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발 (Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application)

  • 박동근;석복열;고태국;강형구
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.