Reviewing Articles Related to Recent Advances in Non-invasive Prenatal Testing and Nursing Implications (최신 비침습적 산전 유전 검사(NIPT)의 임상 적용과 간호학적 의미)

  • Jun, Myunghee;Shin, Gyeyoung;Hur, Myung Haeng;Choi, Kyung-Sook
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.19 no.4
    • /
    • pp.675-683
    • /
    • 2013
  • Purpose: Nineteen articles were analyzed to gather opinions and nursing implications about NIPT recently launched. Methods: Nineteen articles were selected from EBSCO (eBook business collection), Google Scholar, and two Korean academic d-bases with key words 'prenatal screening testing', 'prenatal genetic diagnostic testing', NIPT or 'cell free DNA (cfDNA)'. Authors developed a framework for analyzing the 19 articles including opinions and suggestions for future implications. Results: Eleven articles written by the first author affiliated with medicine or genetics, viewed NIPT as promising because of safety, accuracy, early detectability and cost effectiveness. Articles written by journalists or authors affiliated with history and ethics were concerned with the possible risk of ELSI (ethical, legal, social issues), erratic interpretation of test results, and lack of genetic counseling service. Conclusion: With consideration of Korean clinical, and legal circumstances, not only pregnant women and families but also health professionals must prepare for clinical NIPT implications including updating prenatal genetic testing, counseling services, protecting ELSI and amulticultural team approach.

Analysis for the Fluctuation of the Photoplethysmographic Waveform derived by Temperature Stress of Measuring Position (측정부 온도 부하에 따른 광용적맥파 파형 요동 특성 분석)

  • Lee, Chungkeun;Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.304-309
    • /
    • 2015
  • Applicable range of Photoplethysmography (PPG) becomes wider as a non-invasive physiological measurement technique. However, PPG waveform is easy to be distorted by ambient light or vascular variation from temperature changes. Especially, irregular variation of PPG waveform caused by ambient temperature not only severely distorts the PPG, but also leads miss interpretation in clinical applications. Therefore, the investigation of between temperature and PPG waveform is quite important in using PPG. The purpose of this research is to quantify the PPG waveform characteristic and to investigate the waveform variation following the temperature change on measuring site. To quantify the fluctuation of PPG waveform, we use two techniques; detrended fluctuation analysis (DFA) and AC/DC analysis of PPG. We record PPG under temperature stress, which applied by medical use heat pack ($40^{\circ}C$) and ice pack ($0^{\circ}C$). Ten participants were applied to the experiment, and the result was evaluated to approve the temperature effect with statistical method, Wilcoxon signed rank test. The result shows that the AC component (p<0.05) and perfusion index DFS scale exponent (p<0.01) of PPG have the significance to temperature stress except for a DC component of PPG.

Measurement of Cross-sectional Temperature Distribution in Micro-scale Gap Fluid Using LIF Technique in Combination with CLSM (LIF 및 CLSM을 결합한 미소 간극 내 유체의 단면 온도 분포 측정 기법)

  • Jeong, Dong-Woon;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.834-841
    • /
    • 2006
  • In the present wort the Laser-induced Fluorescence (LIF) technique and Confocal Laser Scanning Microscopy (CLSM) have been combined to measure the temperature distribution across a micro-scale liquid layer as a direct and non-invasive method. Only the fluorescent light emitted from a very thin volume around a focal plane can be selectively detected, and it enables us to measure the liquid temperatures even at the close vicinity of the walls. As an experimental verification, a test section consists of two flat plates (for heating and cooling, respectively) separated by about 240 microns was made, and the methanol mixed with a temperature-sensitive dye, Rhodamine B, was filled in the gap between them. The measured temperature distribution across the gap showed good linearity, which is a typical characteristic of conduction heat transfer through a thin liquid layer. In result, the CLSM-LIF technique proposed in the present study was found to be a promising method to measure the local temperatures in the liquid flow field in microfluidic devices.

A Prediction of Coronary Perfusion Pressure Using the Extracted Parameter From Ventricular Fibrillation ECG Wave (심실세동 심전도 파형 추출 파라미터를 이용한 관상동맥 관류압 예측)

  • Jang Seung-Jin;Hwang Sung-Oh;Yoon Young-Ro;Lee Hyun-Sook
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.4
    • /
    • pp.274-283
    • /
    • 2005
  • Coronary Perfusion Pressure(CPP) is known for the most important parameter related to the Return of Spontaneous Circulation (ROSC), however, clinically measuring CPP is difficult either invasive or non-invaisive method. En this paper, we analyze the correlation between the extracted parameter from VF ECG wave and the CPP with the statistical method, and predict CPP value using the extracted parameters within significance level. the extracted parameters are median frequency(MF), peak frequency(PF), average segment amplitude(ASA), MSA(maximum segment amplitude), Two parameters, MF, and ASA are selected in order to predict CPP value with general regression neural network, and then we evaluated the agreement statistics between the simulated CPP and the measured CPP. In conclusion, the mean and variance of the difference between the simulated CPP and the measured CPP are 8.9716±1.3526 mmHg, and standard deviation 6.4815 mmHg with one hundred-times training and test results. the simulated CPP and the measured CPP are agreed with the overall accuracy $90.68\%$ and kappa coefficient $81.14\%$ as a discriminant parameter of ROSC.

Association between Hand Grip Strength and Gait Variability in Elderly: Pilot Study (노인의 악력과 보행 가변성 간의 연관성: 예비연구)

  • Lee, Do-Youn;Lee, Yungon;Shin, Sunghoon
    • PNF and Movement
    • /
    • v.20 no.1
    • /
    • pp.125-134
    • /
    • 2022
  • Purpose: The aim of this study was to establish an association between grip strength and gait variability in the elderly. Methods: The participants in this experiment (n = 20) were aged 65 or older. Power grip and lateral pinch forces were obtained in grip strength tests, and spatiotemporal gait parameters were collected from IMU sensors during 6 min actual walking to test the gait of participants. The collected gait parameters were converted to coefficient of variation (CV) values. To confirm the association between grip strength and gait variability, a partial correlation analysis was conducted in which height, weight, and gait speed were input as controlling variables. Results: Grip power showed a significant negative correlation with the stride length CV (r = -0.52), and the lateral pinch force showed a significant negative correlation with the stance CV (r = -0.65) and swing CV (r = -0.63). Conclusion: This study reveals that gait variability decreases as grip strength increases, although height, weight, and gait speed were controlled. Thus, grip strength testing, a simple aging evaluation method, can help identify unstable gait in older adults at risk of falling, and grip strength can be utilized as a non-invasive measurement method for frailty management and prevention.

Response Characteristics of the Scattered Signal of a Microwave Reflectometry (마이크로파 Reflectometry의 산란 신호 응답 특성)

  • Baang, Sung-Keun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.5
    • /
    • pp.556-561
    • /
    • 2008
  • The characteristics of microwave reflectometry, which is based on the technologies of FM radar and is applied as a non-invasive method to examine the properties including density distribution of inhomogeneous media, is investigated. The microwave reflectometry system requires not only an optimized system hardware but as well as the understanding of system response from the media under test in order to provide the system solution describing the object under test quantitatively. The introduction of microwave reflectometry especially in the area of applied plasma physics has been relatively new and the number of usage is found to be increasing gradually. The experimental method to characterize the microwave system as a device to examine the properties of plasma is explained. The microwave reflectometry signals consist of the cutoff signals which originate from the region where most of the reflected power comes from and the scattered signals which result as an interaction of the microwave and the density perturbations. This paper describes the experimental results of the scattered signal from the microwave reflectometry, such as the wavenumber dependence and the sensitivity on density perturbation, and the comparison of the characteristics with those from the numerical simulations and those from the cutoff signals.

Colposcopy Requirement of Papanicolaou Smear after Atypical Squamous Cells of Undetermined Significance (ASC-US) by Follow-up Protocol in an Urban Gynaecology Clinic, a Retrospective Study in Thailand

  • Perksanusak, Thitichaya;Sananpanichkul, Panya;Chirdchim, Watcharin;Bhamarapravatana, Kornkarn;Suwannarurk, Komsun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.4977-4980
    • /
    • 2015
  • Background: ASC-US cases are managed according to the current American Society for Colposcopy and Cervical Pathology (ASCCP) guideline in which a human papillomavirus (HPV) test and repeat Pap smear are performed in the next 1 year. Colposcopy in cases of positive high risk HPV and persistent ASC-US or more in subsequent Pap smear is recommended. The HPV test is more expensive and still not currently a routine practice in Thailand. Objective: To identify the risk factors of persisted abnormal Pap smear and the colposcopic requirement rate in women with ASC-US. Materials and Methods: During 2008-2013, this study was conducted in Prapokklao Hospital, Chanthaburi, Thailand. Participants were women who attended gynaecology clinic for cervical cancer screening. Women who had cytological reports with ASC-US were recruited. During the study period, 503 cases were enrolled. Colposcopic requirement was defined as those who were detected with an ASC-US or more in subsequent Pap smears up to 1 year follow-up. Results: The colposcopic referral rate was 23.2 (85/365) percent at 12 months. Prevalence of cervical intraepithelial neoplasia (CIN) 2/3 was 3.3 (12/365) percent. Loss follow-up rate of subsequent Pap smear and colposcopic appointment were 27.4 (138/503) and 48.2 (41/85) percent, respectively. There was no invasive cancer. High risk factors for persisted abnormal Pap smears in subsequent test were premenopausal status, HIV infected patients and non-oral contraceptive pills (COC) users. Conclusions: Referral rate for colposcopy in women with ASC-US reports was rather high. Loss to follow-up rate was the major limitation. Immediate colposcopy should be offered for women who had high risk for silent CIN.

L-Tetrahydropalmatine Ameliorates Development of Anxiety and Depression-Related Symptoms Induced by Single Prolonged Stress in Rats

  • Lee, Bombi;Sur, Bongjun;Yeom, Mijung;Shim, Insop;Lee, Hyejung;Hahm, Dae-Hyun
    • Biomolecules & Therapeutics
    • /
    • v.22 no.3
    • /
    • pp.213-222
    • /
    • 2014
  • Abnormal adaptation of the stress-response system following traumatic stress can lead to alterations in the hypothalamic-pituitaryadrenal (HPA) axis that may contribute to the development of post-traumatic stress disorder (PTSD). The present study used several behavioral tests to investigate the anxiolytic-like and antidepressant activity of L-tetrahydropalmatine (L-THP) in an experimental rat model of anxiety and depression induced by single prolonged stress (SPS), an animal model of PTSD. Male rats were treated intraperitoneally (i.p.) with vehicle or varied doses of THP 30 min prior to SPS for 8 consecutive days. Daily THP (50 mg/kg) administration significantly increased the number and duration of open arm visits in the elevated plus maze (EPM) test, reduced the anxiety index, increased the risk assessment, and increased the number of head dips over the borders of the open arms after SPS. THP was also associated with increased time spent at the center of the open field, reduced grooming behaviors in the EPM test, and reduced time spent immobile in the forced swimming test (FST). It also blocked the decrease in neuropeptide Y (NPY) and the increase in corticotrophin-releasing factor (CRF) expression in the hypothalamus. This is the first study to determine that THP exerts pronounced anxiolytic-like and antidepressant effects on the development of the behavioral and biochemical symptoms associated with PTSD, indicating its prophylactic potential. Thus, THP reversed several behavioral impairments triggered by the traumatic stress of SPS and is a potential non-invasive therapeutic intervention for PTSD.

Plasticity Associated Changes in Neurophysiological Tests Following Non Invasive Brain Stimulation in Stroke Rat Model (뇌졸중 쥐모델에서 비침습적뇌자극치료 이후 신경생리학적 검사에서 나타난 뇌가소성과 연관된 변화)

  • Sohn, Min Kyun;Song, Hee-Jung;Jee, Sungju
    • Annals of Clinical Neurophysiology
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2014
  • Background: Neuromodulation therapy has been used to an adjunctive treatment promoting motor recovery in stroke patients. The objective of the study was to determine the effect of repetitive transcranial magnetic stimulation (rTMS) on neurobehavioral recovery and evoked potentials in rats with middle cerebral artery occlusion. Methods: Seventy Sprague-Daley rats were induced permanent middle cerebral artery occlusion (MCAO) stroke model and successful stroke rats (n=56) assigned to the rTMS (n=28) and sham (n=28) group. The 10 Hz, high frequency rTMS gave on ipsilesional forepaw motor cortex during 2 weeks in rTMS group. The somatosensory evoked potential (SSEP) and motor evoked potential (MEP) were used to evaluate the electrophysiological changes. Behavioral function of the stroke rat was evaluated by the Rota rod and Garcia test. Results: Forty rats ($N_{rTMS}=20;\;N_{sham}=20$) completed all experimental course. The rTMS group showed better performance than sham group in Rota rod test and Garcia test at day 11 (p<0.05) but not day 18 (p>0.05). The amplitude of MEP and SSEP in rTMS group was larger than sham group at day 18 (p<0.05). Conclusions: These data confirm that the high frequency rTMS on ipsilesional cerebral motor cortex can help the early recovery of motor performance in permanent middle cerebral artery stroke model and it may simultaneously associate with changes in neurophysiological activity in brain.

Synthesis and Biocompatibility Study of Hydrogel for Patch Sensor in Non-invasive Glucose Monitoring System (무채혈 혈당 측정시스템의 Patch Sensor용 수화젤의 합성 및 생체적합성에 관한 연구)

  • Kwon, Jeong-Woo;Kim, Dong-Chul;Yoon, In-Joon;Jeong, Yoon-Na;Jeong, Ji-Young;Hwang, In-Sik
    • Polymer(Korea)
    • /
    • v.33 no.2
    • /
    • pp.111-117
    • /
    • 2009
  • This study aims to verify for humans the suitability of the enzyme-fixed hydrogel used for the patch sensor of the blood sugar testing system without blood sampling, which utilizes reverse iontophoresis. Using acrylate monomers, hydrogel was synthesized to which a certain unit of enzyme is fixed. In order to analyze the material property of the synthesized hydrogel, a structural analysis was performed using FT-IR spectroscopy, while the DSC was used to verify the thermal stability. In addition, with the UV-Vis spectrophotometer, it was verified that the degree of active enzyme is at least 50% greater than the standard product. The SEM was used to verify secure fixation of the enzyme onto the surface. As a result, it was observed that the enzyme is successfully fixed to the surface. Since the hydrogel makes direct contact with a patient's skin, it is essential to evaluate the toxicity when making direct contact with the skin. For that purpose, various sets of tests were undertaken according to the ISO 10993-cytotoxicity, intracutaneous reactivity, skin irritation test and maximization sensitization. Consequently, it was successfully verified that the enzyme-fixed hydrogel have bioavailability.