• Title/Summary/Keyword: Non-invasive diagnostic

Search Result 194, Processing Time 0.032 seconds

Diagnostic accuracy of a combination of salivary hemoglobin levels, self-report questionnaires, and age in periodontitis screening

  • Maeng, You-Jin;Kim, Bo-Ra;Jung, Hoi-In;Jung, Ui-Won;Kim, Hee Eun;Kim, Baek-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.1
    • /
    • pp.10-21
    • /
    • 2016
  • Purpose: This study evaluated the predictive performance of a combination of self-report questionnaires, salivary hemoglobin levels, and age as a non-invasive screening method for periodontitis. Methods: The periodontitis status of 202 adults was examined using salivary hemoglobin levels, responses to 10 questions on a self-report questionnaire, and the Community Periodontal Index (CPI). The ability of those two variables and the combination thereof with age to predict the presence of CPI scores of 3-4 and 4 was assessed using logistic regression and receiver operating characteristic (ROC) curve analysis. Results: CPI scores of 3-4 and 4 were present among 79.7% and 46.5% of the sample, respectively. The area under the ROC curves (AUROCs) of salivary hemoglobin levels for predicting prevalence of CPI scores of 3-4 and 4 were 0.63 and 0.67, respectively (with sensitivity values of 71% and 60% and specificity values of 56% and 72%, respectively). Two distinct sets of five questions were associated with CPI scores of 3-4 and 4, with AUROCs of 0.73 and 0.71, sensitivity values of 76% and 66%, and specificity values of 63% and 69%. The combined model incorporating both variables and age showed the best predictive performance, with AUROCs of 0.78 and 0.76, sensitivity values of 71% and 65%, and specificity values of 68% and 77% for CPI scores of 3-4 and 4, respectively. Conclusions: The combination of salivary hemoglobin levels and self-report questionnaires was shown to be a valuable screening method for detecting periodontitis.

Determination of Tricuspid Regurgitation Velocity/Pulmonary Artery Flow Velocity Time Integral in Dogs with Pulmonary Hypertension

  • Kim, Seungji;Oh, Dayoung;Lee, Siheon;Hong, Sungkyun;Choi, Mincheol;Yoon, Junghee
    • Journal of Veterinary Clinics
    • /
    • v.37 no.4
    • /
    • pp.185-190
    • /
    • 2020
  • This retrospective, echocardiographic study using 144 dogs with clear systolic tricuspid regurgitation on Doppler echocardiography was performed to determine the diagnostic value of the systolic tricuspid regurgitation velocity/pulmonary artery flow velocity time integral to predict the Doppler estimates of dogs with tricuspid regurgitation pressure gradient compared with other cardiac indices of pulmonary hypertension, and to investigate a cutoff value to select patients with a potentially poor outcome. The systolic tricuspid regurgitation velocity/pulmonary artery flow velocity time integral increased significantly as the severity of pulmonary hypertension increased and had a correlation coefficient that was analogous to those of other conventional cardiac indices. A cutoff value greater 1.65 provided the best-balanced sensitivity (84%) and specificity (80%) in determining patients with a poor prognosis. In conclusion, the systolic tricuspid regurgitation velocity/pulmonary artery flow velocity time integral is readily obtained using routine echocardiography and could provide a non-invasive, novel, and supplementary index for evaluating dogs with pulmonary hypertension as useful prognostic criteria, particularly in those with advanced pulmonary hypertension.

Role of Three-dimensional Computed Tomography Angiography in the Follow-up of Patients with Aneurysm Clips

  • Park, Seong-Hyun;Park, Jae-Chan;Hwang, Jeong-Hyun;Hwang, Sung-Kyoo;Hamm, In-Suk
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.6
    • /
    • pp.427-431
    • /
    • 2006
  • Objective : The purpose of this study is to assess the usefulness of three-dimensional computed tomography angiography [3D-CTA] as a postoperative follow-up examination after intracranial aneurysms have been clipped. Methods : Between January 2002 and June 2005, 522 consecutive patients received treatment for intracranial aneurysms. A retrospective analysis of 310 patients with postoperative 3D-CTAs was performed to evaluate aneurysmal remnants and de novo aneurysms. This study was conducted in 271 patients with at least immediate and 6-month routine 3D-CT As for postoperative clipped aneurysm and 39 patients with 3D-CTAs for clipped aneurysm before 2002 when there was no 3D-CTA in our hospital. Results : Eight patients had abnormal CT angiographic findings. Aneurysm remnants were revealed in 4 patients and de novo aneurysms were discovered in 5 patients. Two patients were found at the postoperative 6-month 3D-CTA performed routinely. In 1 patient, the aneurysm was demonstrated on the way to the examination of syncope. In 2 patients, the author recommended 3D-CTA although there was no symptom because the patients had visited our institute long time ago [5.1, 4.5 years]. Of the 8 patients, 2 remnants and 1 de novo aneurysm were treated by endovascular treatment. Three de novo aneurysms at the middle cerebral artery and 1 pericallosal artery aneurysm were treated by direct clipping because these aneurysms were not suitable for the endovascular treatment in point of anatomical configuration. One patient with both remnant and de novo aneurysm was treated conservatively. Conclusion : 3D-CTA is an available, non-invasive diagnostic tool for the postoperative follow-up examination of aneurysmal state in patients after clipping.

Review of Traditional Chinese Medicine Studies on The Effect of Pediatirc Tuina Massage Concomitant Treatment on Children's Epilepsy (소아 뇌전증 (전간(癲癎))에 소아 추나 동시 치료가 미치는 영향에 대한 중의학 연구 고찰)

  • Park, Jem Ma
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.112-124
    • /
    • 2021
  • Objectives The aim of this study is to examine the effects of Pediatric Tuina Massage (PTM) as a treatment of Chlidren's Epilepsy (CE) and to seek guidance for future follow-up studies and the use of Pediatric Tuina Massage (PTM) in clinical setting. Methods The articles were obtained from the China National Knowledge Infrastructure (CNKI) from 2000 to 2021 by key words 'epilepsy', '癲癎', '癲癎病', 'infantile spasm', '婴幼儿痉挛', '小儿发作', '婴幼儿痉挛' and '推拿', '按摩', 'Tuina', 'Chuna', 'massage' in cross combination way. Results Seven articles were selected and analyzed by authors, years published, characteristics, diagnostic criteria, treatment methods and contents, treatment periods, evaluation criteria and research results. Also, stability and side effects were reviewed, and the qualities of the randomized controlled trials (RCT) were evaluated according to Risks of Bias 2 (RoB 2). All studies using Pediatric Tuina Massage (PTM) treatment have achieved effective therapeutic results for treating Children's epilepsy (CE). Conclusion Pediatric Tuina Massage (PTM) is economical, safe without side effects and non-invasive, but still produce a good effect. Also, it is a good treatment option for children who feels anxious of ordinary Korean Medical treatment such as acupuncture, moxa, herbal medicine, which also results in good compliance with the treatment. In addition, it is possible to enhance therapeutic effect by combining it with pharmacological therapies in treating children's epilepsy (CE). Therefore, Pediatric Tuina Massage (PTM) provides an essential clinical basis in guiding further studies for the treatment of CE.

Hair microscopy: an easy adjunct to diagnosis of systemic diseases in children

  • Dharmagat Bhattarai;Aaqib Zafar Banday;Rohit Sadanand;Kanika Arora;Gurjit Kaur;Satish Sharma;Amit Rawat
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.18.1-18.12
    • /
    • 2021
  • Hair, having distinct stages of growth, is a dynamic component of the integumentary system. Nonetheless, derangement in its structure and growth pattern often provides vital clues for the diagnosis of systemic diseases. Assessment of the hair structure by various microscopy techniques is, hence, a valuable tool for the diagnosis of several systemic and cutaneous disorders. Systemic illnesses like Comel-Netherton syndrome, Griscelli syndrome, Chediak Higashi syndrome, and Menkes disease display pathognomonic findings on hair microscopy which, consequently, provide crucial evidence for disease diagnosis. With minimal training, light microscopy of the hair can easily be performed even by clinicians and other health care providers which can, thus, serve as a useful tool for disease diagnosis at the patient's bedside. This is especially true for resource-constrained settings where access and availability of advanced investigations (like molecular diagnostics) is a major constraint. Despite its immense clinical utility and non-invasive nature, hair microscopy seems to be an underutilized diagnostic modality. Lack of awareness regarding the important findings on hair microscopy may be one of the crucial reasons for its underutilization. Herein, we, therefore, present a comprehensive overview of the available methods for hair microscopy and the pertinent findings that can be observed in various diseases.

Development of a Novel ATP Bioluminescence Assay Based on Engineered Probiotic Saccharomyces boulardii Expressing Firefly Luciferase

  • Ji Sun Park;Young-Woo Kim;Hyungdong Kim;Sun-Ki Kim;Kyeongsoon Park
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.11
    • /
    • pp.1506-1512
    • /
    • 2023
  • Quantitative analysis of adenosine triphosphate (ATP) has been widely used as a diagnostic tool in the food and medical industries. Particularly, the pathogenesis of a few diseases including inflammatory bowel disease (IBD) is closely related to high ATP concentrations. A bioluminescent D-luciferin/luciferase system, which includes a luciferase (FLuc) from the firefly Photinus pyralis as a key component, is the most commonly used method for the detection and quantification of ATP. Here, instead of isolating FLuc produced in recombinant Escherichia coli, we aimed to develop a whole-cell biocatalyst system that does not require extraction and purification of FLuc. To this end, the gene coding for FLuc was introduced into the genome of probiotic Saccharomyces boulardii using the CRISPR/Cas9-based genome editing system. The linear relationship (r2 = 0.9561) between ATP levels and bioluminescence generated from the engineered S. boulardii expressing FLuc was observed in vitro. To explore the feasibility of using the engineered S. boulardii expressing FLuc as a whole-cell biosensor to detect inflammation biomarker (i.e., ATP) in the gut, a colitis mouse model was established using dextran sodium sulfate as a colitogenic compound. Our findings demonstrated that the whole-cell biosensor can detect elevated ATP levels during gut inflammation in mice. Therefore, the simple and powerful method developed herein could be applied for non-invasive IBD diagnosis.

Cardiovascular Magnetic Resonance Versus Histopathologic Study for Diagnosis of Benign and Malignant Cardiac Tumours: A Systematic Review and Meta-Analysis

  • Sandra Nobrega;Catarina Martins da Costa;Ana Filipa Amador;Sofia Justo;Elisabete Martins
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.159-168
    • /
    • 2023
  • BACKGROUND: The gold standard for diagnosis of cardiac tumours is histopathological examination. Cardiovascular magnetic resonance (CMR) is a valuable non-invasive, radiation-free tool for identifying and characterizing cardiac tumours. Our aim is to understand CMR diagnosis of cardiac tumours by distinguishing benign vs. malignant tumours compared to the gold standard. METHODS: A systematic search was performed in the PubMed, Web of Science, and Scopus databases up to December 2022, and the results were reviewed by 2 independent investigators. Studies reporting CMR diagnosis were included in a meta-analysis, and pooled measures were obtained. The risk of bias was assessed using the Quality Assessment Tools from the National Institutes of Health. RESULTS: A total of 2,321 results was obtained; 10 studies were eligible, including one identified by citation search. Eight studies were included in the meta-analysis, which presented a pooled sensitivity of 93% and specificity of 94%, a diagnostic odds ratio of 185, and an area under the curve of 0.98 for CMR diagnosis of benign vs. malignant tumours. Additionally, 4 studies evaluated whether CMR diagnosis of cardiac tumours matched specific histopathological subtypes, with 73.6% achieving the correct diagnosis. CONCLUSIONS: To the best of our knowledge, this is the first published systematic review on CMR diagnosis of cardiac tumours. Compared to histopathological results, the ability to discriminate benign from malignant tumours was good but not outstanding. However, significant heterogeneity may have had an impact on our findings.

Disease Testing in Pelvic Pain Patients: Comparison between Ultrasound and Computed Tomography Imaging (골반통 환자의 질환 검사: 초음파와 컴퓨터단층촬영 간의 비교)

  • EunHoe Goo
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.385-390
    • /
    • 2023
  • The uterus, one of women's reproductive organs, is also closely related to women's health. Among them, hemorrhagic luteal cysts, one of the causes of pelvic pain that women often experience, were observed through CT and ultrasound, and the quality of images was evaluated through quantitative and qualitative evaluations. This study sought to find out whether the test method is more helpful to patients during CT and ultrasound. This study was conducted on 15 adolescent women and 15 adult women(21.31±3.45 average age). The equipment used for filming used EC3-10X (3~10 MHZ) and Philips Mx8000 iCT 256 among Endocavity Probes among Ecube Platinum. After setting a constant ROI on the cyst and the interface as a quantitative analysis method, SNR and CNR values were measured on a 5-point scale based on image quality, lesion clarity, image distortion, clarity of the interface, and motion artifacts (p<0.05). Independent t-test and Mann Whiteny U were performed, and the statistical program used was noted when SPSS (Version 22.0 for windows software package, Chicago, IL, USA) was statistically less than 0.05. Comparing the SNR and CNR values for this experiment, it can be seen that the SNR value was higher in the case of CT images(p<0.05). As a result of the qualitative evaluation, the quality of the image, the clarity of the lesion, the distortion of the image, the clarity of the interface, and the clarity of the boundary were measured on a 5-point scale based on the movement artifact. Comparing each score, CT images scored higher with a finer difference than ultrasound images(p<0.05). In conclusion, both test methods showed excellent results in finding the patient's lesions. However, in quantitative and qualitative evaluations, CT produced higher results in detecting lesions than ultrasound. However, for cyst tests that require continuous observation, ultrasonography, a non-invasive method that is advantageous for patients, will be clinically useful. Therefore, observing the patient's lesions by appropriately distributing these two test methods will provide optimal diagnostic information. These results will be useful for providing clinical basic data and educational materials to CT and US users in the future.

Development of Artificial Pulmonary Nodule for Evaluation of Motion on Diagnostic Imaging and Radiotherapy (움직임 기반 진단 및 치료 평가를 위한 인공폐결절 개발)

  • Woo, Sang-Keun;Park, Nohwon;Park, Seungwoo;Yu, Jung Woo;Han, Suchul;Lee, Seungjun;Kim, Kyeong Min;Kang, Joo Hyun;Ji, Young Hoon;Eom, Kidong
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • Previous studies about effect of respiratory motion on diagnostic imaging and radiation therapy have been performed by monitoring external motions but these can not reflect internal organ motion well. The aim of this study was to develope the artificial pulmonary nodule able to perform non-invasive implantation to dogs in the thorax and to evaluate applicability of the model to respiratory motion studies on PET image acquisition and radiation delivery by phantom studies. Artificial pulmonary nodule was developed on the basis of 8 Fr disposable gastric feeding tube. Four anesthetized dogs underwent implantation of the models via trachea and implanted locations of the models were confirmed by fluoroscopic images. Artificial pulmonary nodule models for PET injected $^{18}F$-FDG and mounted on the respiratory motion phantom. PET images of those acquired under static, 10-rpm- and 15-rpm-longitudinal round motion status. Artificial pulmonary nodule models for radiation delivery inserted glass dosemeter and mounted on the respiratory motion phantom. Radiation delivery was performed at 1 Gy under static, 10-rpm- and 15-rpm-longitudinal round motion status. Fluoroscpic images showed that all models implanted in the proximal caudal bronchiole and location of models changed as respiratory cycle. Artificial pulmonary nodule model showed motion artifact as respiratory motion on PET images. SNR of respiratory gated images was 7.21. which was decreased when compared with that of reference images 10.15. However, counts of respiratory images on profiles showed similar pattern with those of reference images when compared with those of static images, and it is assured that reconstruction of images using by respiratory gating improved image quality. Delivery dose to glass dosemeter inserted in the models were same under static and 10-rpm-longitudinal motion status with 0.91 Gy, but dose delivered under 15-rpm-longitudinal motion status was decreased with 0.90 Gy. Mild decrease of delivered radiation dose confirmed by electrometer. The model implanted in the proximal caudal bronchiole with high feasibility and reflected pulmonary internal motion on fluoroscopic images. Motion artifact could show on PET images and respiratory motion resulted in mild blurring during radiation delivery. So, the artificial pulmonary nodule model will be useful tools for study about evaluation of motion on diagnostic imaging and radiation therapy using laboratory animals.

Role of enzyme immunoassay for the Detection of Helicobacter pylori Stool Antigen in Confirming Eradication After Quadruple Therapy in Children (소아에서 4제요법 후 enzyme immunoassay에 의한 Helicobacter pylori 대변 항원 검출법의 유용성에 대한 연구)

  • Yang, Hye Ran;Seo, Jeong Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.2
    • /
    • pp.153-162
    • /
    • 2004
  • Purpose: The Helicobacter pylori stool antigen (HpSA) enzyme immunoassay is a non-invasive test for the diagnosis and monitoring of H. pylori infection. But, there are few validation studies on the HpSA test after eradication in children. The aim of this study was to assess the diagnostic accuracy of HpSA enzyme immunoassay for the detection of H. pylori to confirm eradication in children. Methods: From January 2001 to October 2003, 164 tests were performed in 146 children aged 1 to 17.5 years (mean $9.3{\pm}4.3$ years). H. pylori infection was confirmed by endoscopy-based tests (rapid urease test, histology, and culture). All H. pylori infected children were treated with quadruple regimens (Omeprazole, amoxicillin, metronidazole and bismuth subcitrate for 7 days). Stool specimens were collected from all patients for the HpSA enzyme immunoassay (Primier platinum HpSA). The results of HpSA tests were interpreted as positive for $OD{\geq}0.160$, unresolved for $$0.140{\leq_-}OD$$<0.160, and negative for OD<0.140 at 450 nm on spectrophotometer. Results: 1) One hundred thirty-one HpSA tests were performed before treatment. The result of HpSA enzyme immunoassay showed three false positive cases and one false negative case. The sensitivity, specificity, positive predictive value, and negative predictive value of HpSA enzyme immunoassay before treatment were 96.4%, 97.1%, 90%, and 99%, respectively. 2) Thirty-three HpSA enzyme immunoassay were performed at least 4 weeks after eradication therapy. The results of HpSA enzyme immunoassay showed two false positive cases and one false negative case. The sensitivity, specificity, positive predictive value, and negative predictive value after treatment were 88.9%, 91.7%, 80%, and 95.7%, respectively. Conclusion: Diagnostic accuracy of the HpSA enzyme immunoassay after eradication therapy was as high as that of the HpSA test before eradication therapy. The HpSA enzyme immunoassay was found to be a useful non-invasive method to confirm H. pylori eradication in children.

  • PDF