• Title/Summary/Keyword: Non-injection

Search Result 1,053, Processing Time 0.032 seconds

Analysis on Position Estimation Performance according to Injection Frequency in Carrier-Based Sensorless Operation (반송파 기반 센서리스 운전에서 주입하는 신호의 주파수에 따른 위치 추정 성능 분석)

  • Hwang, Chae-Eun;Lee, Younggi;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.139-146
    • /
    • 2018
  • This work puts forward a theoretical analysis on position estimation performance of interior permanent magnet synchronous motor (IPMSM) according to the injection frequency in carrier-based sensorless operation. The effects of spatial harmonics on inductance and voltage distortion due to the nonideal characteristics of IPMSM and inverter are examined as factors influencing the position estimation performance. Furthermore, the position estimation performance is analyzed by calculating the current at the switching instant in several operating conditions. In summary, the half switching frequency injection is more robust to the nonideal characteristics of IPMSM, especially with light load condition. The validity of the analysis is verified by the simulation and experimental results.

Selecting the Optimum Condition of Injection Molding Process by the Taguchi Method and Neural Network (다구찌 방법과 신경회로망을 이용한 사출성형 가공공정의 최적 가공조건 선정에 관한 연구)

  • 홍정의
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.25 no.2
    • /
    • pp.71-76
    • /
    • 2002
  • Defining the relationship between the quality of Injection molded parts and the process condition is very complicate because of lots of factors are involved and each factor has a non-linearity. With the development of CAE(Computer Aided Engineering) technology, the estimation of volumetric shrinkage of injection mold parts is possible by computer simulation in spite of restricted application. In this research, the Taguchi method md Neural Network are applied for finding optimal processing condition. The percent of volumetric shrinkage is compared on each case and shows neural network can be successfully applied.

Local Irritation of DA-3285, Recombinant Human Erythropoietin (유전자재조합법으로 생산한 human erythropoietin(DA-3285)의 국소자극성에 관한 연구)

  • 김옥진;김동환;안병옥;김원배;양중익
    • Toxicological Research
    • /
    • v.12 no.1
    • /
    • pp.101-111
    • /
    • 1996
  • The local irritation studies of DA-3285, recombinant human erytropoietin(rHu-EPO), were carried out in rabbits after the following treatment; single application into the conjunctival sac of the eye, single subcutaneous injection, 7-day repeated subcutaneous injection and 8-day repeated infusion into the ear vein. Also, the local irritancy of DA-3285 leaked around vein was studied in mice by single perivascular injection. The results obtained were as follows. In the result of ocular irritation test, DA-3285 could be considered as a non-irritating material. In single and 7-day repeated subcutaneous irritation test, the irritancy of DA-3285 was not so much different from that of saline. The vascular irritancy of DA3285 by 8-day repeated infusion was negligible and similar to that of saline. And the irritancy of DA3285 by perivascular injection was comparable to that of saline. These results indicate that DA-3285 has no irritating activity when injected through subcutaneous or intravenous route for clinical practice as 3.5% solution.

  • PDF

Effects of Reduced Glutathione on Non-Protein Sulfhydryl, Non-Protein Disulfide and Oxygen Consumption Rate of Mouse Duodenum Following Whole Body X-Irradiation (Reduced Glutathione 이 X-선전신조사(線全身照射)를 입은 마우스 십이지장(十二指腸)의 NP-SH, NP-SS 및 산소소비량(酸素消費量)에 미치는 영향(影響))

  • Lee, Joong-Kil;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.5 no.2
    • /
    • pp.55-62
    • /
    • 1971
  • In an attempt to better understand the effects of whole body X-irradiation on the levels of non-protein sulfhydryl (NP-SH), non-protein disulfide (NP-SS) and oxygen consumption rate $(QO_2)$ of the mouse duodenum, and to clarify the possible radioprotective action of reduced glutathione (GSH), a whole body X-irradiation of 1,000r was given to albino mouse either singularly or immediately after injecting GSH intraperitoneally to mouse 1 mg per gm of body weight. NP-SH was measured by Ellman's method, NP-SS was measured by the electrolytic reduction method described by Dohan and Woodward, and $(QO_2)$ by the Warburg's standard manometric method. The experiment was performed at 1, 6, 12 and 24 hours post-irradiation, and the comparison was made with the control. The results thus obtained are summarized as follows: 1) Comparing with the intrinsic NP-SH level of $3.31{\pm}0.27{\mu}\;mol/gm$ wet weight in the duodenum of the normal mouse, either whale body X-irradiation or injection of GSH alone produced no significant change in NP-SH from the normal. However, when GSH was injected prior to X-irradiation, markedly elevated NP-SH levels were observed throughout the entire experiment with the highest value of $4.70{\pm}0.10$ at 6 experimental hours. 2) The normal value of NP-SS in the mouse duodenum was $1.57{\pm}0.17{\mu}\;mol/gm$ wet weight, while in the group where injection of GSH and X-irradiation were combined, NP-SS increased to $2.36{\pm}0.33$ at 12 hours and $2.15{\pm}0.53$ at 24 hours, showing the intermediate value between the GSH injection group and X·irradiation group. 3) The normal value of $(QO_2)$ was $4.16{\pm}0.73{\mu}l\;O_2/hr./gm$ D.W., and no noticeable change was observed comparing with the GSH injection group. However, in the group where X·irradiation alone was given, $(QO_2)$ of the duodenum increased significantly throughout the entire experiment with the highest value of $6.35{\pm}1.07$ at 6 experimental hours. When GSH was injected before X-irradiation was given, the levels of $(QO_2)$ were in the middle of the GSH injection group and X-irradiation group. 4) The above results suggest that GSH may be effective as a radioprotector in terms of NP-SH, NP-SS and $(QO_2)$ of the mouse duodenum.

  • PDF

Studies on Local Irritation of DA-3030, a new granulocyte colony stimulating factor (새로운 과립구 콜로니 자극인자(rhG-CSF) DA-3030의 국소자극성에 관한 연구)

  • 김옥진;안병옥;이순복;김원배;양중익
    • Biomolecules & Therapeutics
    • /
    • v.2 no.3
    • /
    • pp.247-255
    • /
    • 1994
  • As a series of safety studies of DA-3030, a new rhO-CSF, its local irritancy was examined in the rabbits after the following treatment; application into the conjunctival sac of the eye(single), subcutaneous injection(single), intramuscular injection(single), and intravenous injection(8-day repeated). In addition, paravenous irritation of DA-3030 was investigated in mice. The results obtained were as follows. 1. In the result of ocular irritation test, 0.03% solution of DA-3030 could be considered as a non-irritating material. 2. The local irritation of DA-3030 by an injection of 0.5mι of its solution subcutaneously or intramuscularly was negligible and not so much different from that of saline. 3. In the vascular irritancy test, macro- and microscopic observations revealed that the irritating activity of DA-3030 in blood vessels was not different from that of saline when they were injected once a day into vein retroauricularis of rabbits for 8 days.4. The paravenous administration of DA-3030 did not induce any abnormal changes at injection sites except mild swelling in 1 mouse at 3 hours after injection which was thought to be due to slow absorption. The above-mentioned results suggest that DA-3030 has no irritating activity when injected through intravenous or subcutaneous route for clinical practice as 0.03% solution.

  • PDF

Intelligent Design System for Gate and Runner in Injection Molding (사출성형을 위한 게이트.런너 지적설계시스템에 관한 연구)

  • Lee, Chan-Woo;Huh, Yong-Jeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.192-203
    • /
    • 2001
  • The design of gate and runner(delivery system) is one of the most important subject in injection molding. Delivery system is a channel to flow the polymer melt from the injection molding machine to the mold cavities. Also, delivery system affect quality and productivity of the part. The synthesis of delivery system of injection molding has been done empirically, since it requires profound knowledge about the moldability and causal effects on the properties of the part, which are not available to designers through the current CAD systems. GATEWAY is a knowledge module which contains knowledge to permit non-experts as well as mold design experts to generate the acceptable geometries of gate and runner far injection molded parts. A knowledge-based CAD system is constructed by adding the knowledge module, GATEWAY, to an existing geometric modeler. A knowledge-based CAD system is a new tool which enables the concurrent design and CIM with integrated and balanced design decisions at the initial design of injection molding.

  • PDF

Effects of processing Factors on Filling Imbalances in Multi-cavity Injection Mold. (다수 캐비티 사출금형에서 성형 인자가 충전 불균형에 미치는 영향)

  • Kang C. M.;Jeong Y. D.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.54-57
    • /
    • 2004
  • Almost all injection molds have multi-cavity runner for mass production, which are designed with geometrically balanced runner system in order to minimize filling imbalance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalances have sometimes been observed. These filling imbalances have historically been considered as result of uneven mold temperature and mold deflection, but it actually results from non-symmetrically shear, pressure, temperature distribution within melt material as it flows through the runner system. Filling imbalance could be decreased by modifying processing conditions that are related to shear, pressure, temperature such as injection rate, mold temperature, injection pressure, melt temperature. In this study, a series of experiment was conducted using Taguchi method to determine which processing condition influence as the primary cause of filling imbalance in geometrically balanced runner system. As a result of experiments, this paper could present an optimal processing condition to minimize variable that brings about filling imbalance geometrically balanced runner system

  • PDF

A Study for Optimal Design of the AIG to Improve the Performance of DeNOx Facilities Installed in Combined Cycle Plant (복합화력 탈질설비 성능향상을 위한 암모니아 주입 그리드의 최적설계 방안에 관한 연구)

  • Kim, Kwang-Chu;Park, Man-Heung;Yoon, Jun-Kyu;Lim, Jong-Han
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.811-820
    • /
    • 2007
  • A Study on the optimal design of the AIG(Ammonia Injection Grid) to improve the performance of DeNOx facilities in the HRSG(Heat Recovery Steam Generator) was performed using the CFD analysis. On the basis of the flow analysis results in the case that the AIG in the HRSG was not installed, the numerical analyses according to the positions of AIG, injection angles of nozzle and the control of ammonia injection quantity were carried out. The standard deviation according to factors was calculated for quantitative comparison. As the results, the AIG in the HRSG should be installed in the position that the uniform flow field shows through the exact flow analysis in the previous of the AIG design and installation. In the case the AIG has already been installed and non uniform flow distribution shows, it is recommended that flow correction device or KoNOx catalyst should be used. Otherwise, the control of ammonia injection angle or the ammonia injection quantity using the velocity profile analysis is demanded to accomplish the optimal performance.

Resin Content and Dimensional Rise in Board Impregnated with Phenol Resin for Making Woodceramics - Effect of Steam Injection Time - (우드세라믹 제조용 석탄산수지 함침보드의 수지 함침율과 치수 증가율 - 증기분사 시간의 영향 -)

  • Oh, Seung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.158-164
    • /
    • 2002
  • The properties of new porous carbon materials "Woodceramics" are affected by the characteristics of raw boards. To investigate of density profile and resin contents in impregnated boards, control board and 3 types of steam-injected boards were made by steam injection time, The wood species used for manufacturing boards was Sugi(Cryptomeria japonica). The results are as follows: 1) The density gradient of board after 10 minutes steam injection was the smallest and non-steamed board was largest. 2) The resin content and dimensional rise decreased with increase of board density, and were the largest in board after 10minutes steam injection but there was little difference between boards after 5 and 10 minutes steam injection.

Effects of Fasting versus Non-Fasting on Emetic Complications in Radiological Examinations Using Intravascular Non-Ionic Iodinated Contrast Media: A Systematic Review and Meta-Analysis

  • Hyewon Choi;Hyunsook Hong;Min Jae Cha;Soon Ho Yoon
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.996-1005
    • /
    • 2023
  • Objective: To compare the incidence of aspiration pneumonia, nausea, and vomiting after intravascular administration of nonionic iodinated contrast media (ICM) between patients who fasted before contrast injection and those who did not. Materials and Methods: Ovid-MEDLINE and Embase databases were searched from their inception dates until September 2022 to identify original articles that met the following criteria: 1) randomized controlled trials or observational studies, 2) separate reports of the incidence of aspiration pneumonia, nausea, and vomiting after intravascular injection of non-ionic ICM, and 3) inclusion of patients undergoing radiological examinations without fasting. A bivariate beta-binomial model was used to compare the risk difference in adverse events between fasting and non-fasting groups. The I2 statistic was used to assess heterogeneity across the studies. Results: Ten studies, encompassing 308013 patients (non-fasting, 158442), were included in this meta-analysis. No cases of aspiration pneumonia were reported. The pooled incidence of nausea was 4.6% (95% confidence interval [CI]: 1.4%, 7.8%) in the fasting group and 4.6% (95% CI: 1.1%, 8.1%) in the non-fasting group. The pooled incidence of vomiting was 2.1% (95% CI: 0.0%, 4.2%) in the fasting group and 2.5% (95% CI: 0.7%, 4.2%) in the non-fasting group. The risk difference (incidence in the non-fasting group-incidence in the fasting group) in the incidence of nausea and vomiting was 0.0% (95% CI: -4.7%, 4.7%) and 0.4% (95% CI: -2.3%, 3.1%), respectively. Heterogeneity between the studies was low (I2 = 0%-13.5%). Conclusion: Lack of fasting before intravascular administration of non-ionic ICM for radiological examinations did not increase the risk of emetic complications significantly. This finding suggests that hospitals can relax fasting policies without compromising patient safety.