• Title/Summary/Keyword: Non-contact power supply

검색결과 26건 처리시간 0.022초

High-Efficiency Non-contact Power Supply System

  • Zheng, Bin;Kwan, Dae-Hwan;Lee, Dae-Sik
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.233-235
    • /
    • 2005
  • Non-contact power supply (NCPS), as a clean and safe energy supply concept has been applying wildly. Comparing with the conventional transformer the non-contact transformer has a large air gap between the long primary winding and the secondary winding. Due to it, the non-contact transformer has increased leakage inductance and reduced magnetizing inductance. So the high frequency series resonant converter has been widly used on the non-contact power supply system for transferring the primary power to the secondary one, from what a high influence voltage can be gained on the secondry coil even though the large air gap exists. However, it still has the disadvantages of the load sensitive voltage gain characteristics when load is changing. In this paper, we propose a fuzzy logic controller to adjust the frequency of the inverter to track the resonat which is changing when the load is change.

  • PDF

비접촉 전원장치의 비접촉 커플러 설계 (Non contact Coupler Design in Non contact Power Supply)

  • 류명효;차헌녕;백주원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1500-1502
    • /
    • 2005
  • In this paper, the electrical characteristics of the non-contact transformer is presented using conventional coupled inductor theory. Each non-contact transformer is analyzed through simulation and measurement. In high power applications, non-contact transformer is so bulky and heavy that it should be split by some light transformers. So non-contact transformer needs several small transformer modules which are connected series or parallel to transfer the primary power to the secondary one. This paper shows analytic result of the each non-contact transformer module and comparison result between series-connection and parallel-connection of the non-contact transformer. The results are verified on the simulation based on the theoretical analysis and the 30kW experimental prototype.

  • PDF

POWER TRANSMISSION CHARACTERISTICS OF FEASIBLE NON-CONTACT PICK-UP COIL COUPLED TO HIGH-FREQUENCY POWER SUPPLY SYSTEM

  • Kuroda, Mitsuyoshi;Tsuda, Masanori;Okuno, Atsushi;Gamage, Laknath;Mutsuo, Nakaoka
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.447-451
    • /
    • 1998
  • This paper conducts a study on a non-contact power delivering system using high-frequency inverter with the purpose of discussing the non-contact electric power transmission characteristics through circuit analysis, magnetic analysis and feasible experiments. In this power delivering scheme, various properties pertaining to the non-contact transformer of the power system such as the design, the core depth, core material, primary side frequency etc. are considered with a view of improving the non-contact power dilivery to the secondary.

  • PDF

직ㆍ병렬 공진형 컨버터를 이용한 비접촉전원 (Non-Contact Power Supply Using the Series-Parallel Resonant Converter)

  • 공영수;김은수;양승철;김종무;신병철
    • 전력전자학회논문지
    • /
    • 제9권5호
    • /
    • pp.405-412
    • /
    • 2004
  • 본 논문에서는 1차 측이 20m이상의 긴 트랙케이블(Track Cable)로 2차 측은 큰 에어 갭(Air-gap)을 갖는 픽업코일(Pick-up Coil)로 구성되어 있는 비접촉 전원에 대해서 서술하였다. 이러한 비접촉 전원은 1차 측 누설 인덕턴스가 자화 인덕턴스보다 크기 때문에 커플링이 좋지 않아 1차 측의 에너지를 2차 측으로 효율적으로 전달 할 수 없다. 이와 같은 문제점을 개선하기 위하여 본 논문에서는 직렬공진 컨버터, 병렬공진 컨버터 그리고 직ㆍ병렬공진 컨버터(SPRC)의 주 회로를 해석하였고, 각 회로에 대한 전압이득 특성을 비교 검토하였다. 그리고 10kW 직ㆍ병렬공진 컨버터(SPRC)에 대한 실험결과를 서술했다.

고속카메라를 이용한 전차선 마모 검측 영상처리 알고리즘 개발 (Development of a Technique for Detection of Contact Wire Wear using High-Speed Camera)

  • 박영;조용현;조철진;김원하
    • 한국전기전자재료학회논문지
    • /
    • 제23권8호
    • /
    • pp.632-637
    • /
    • 2010
  • The measurement of contact wire wear in electric railways is one of the key test parameters to increase speed and maintain safety in electric railways. Wear caused by continuous interaction between pantographs and contact wires has a negative effect on current collection quality and severely damaged contact wires might cause hazardous accidents. This paper introduces a non-contact optical-based contact wire wear measuring system that will replace conventional wear detecting methods conducted by maintenance vehicles or workers. The system is implemented by high-speed cameras that can collect images of contact wires during vehicle operation, a laser used to create images profile of the contact wire surface, and a computer used to process the collected images. The proposed system is designed to assist maintenance of overhead contact lines by creating geometrically plotted images of contact wires to detect contact wire wear during operation on conventional lines or high-speed lines.

선량계의 무선전력 전송 메카니즘과 데이터 통신 시스템 구현 (Power Transmission Mechanism and Data Communication of the Dosimeter using Contactless Powerless Transmission)

  • 이승민;정성인;이흥호
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.814-819
    • /
    • 2010
  • This study proposes the antenna circuit design for the transmitting wireless power, the development of the RF non-contact type Dosimeter. That is, the study designed the optimization and numerical analysis of the antenna circuit for the antenna design of 13.56MHz over the frequency bands for transmitting wireless power. We studied the needed items in the existing RF type Dosimeter with battery to implement the wireless power non-contact Dosimeter within the battery. We compared to the real measurement value as calculating the value of the inductance and capacitance through the numerical analysis for the antenna LC resonance using the theory of the electromagnetic induction method. This method to drive low power is designed to simplify the circuit and to improve the efficiency of the rectifier. We convince our research contributes not only to understand the simplified circuit and miniaturization, but also to help the design and application technology of the wireless power transmit system which is received power supply with wireless.

전압제어 회로에 의한 호이스트용 통합 드라이브 장치 (The Integration Drive Equipment for Hoistby using Voltage Control Circuit)

  • 라병훈;송대현;서기영;고희석;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.281-286
    • /
    • 2002
  • An existent hoist drive system is using each different drive equipment in control of Hoisting, traveling(T/L), traversing(T/S) driving, so there are much energy losses because of excessive weight. Also, power circuits are using relay contact, so working environment are frequent secession accident etc.. by shock on unfavorable condition, and there is danger of safety accident, maintenance has frequent problem and so on. To solve these problem, it is integrated each driving power supply in drive system for hoist control and drive, utility power supply etc.. by single device in this research. The power circuit is consisted of non-contact circuit applying to bidirectional voltage controller circuit using thyristor that is power semiconductor switching device

  • PDF

낮은 커플링 변압기를 갖는 개선된 고효율 공진 컨버터 (An improved high efficiency resonant converter with low coupling transformer)

  • 공영수;김은수;양승철;박진영;김종무;강도현;조정구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1166-1168
    • /
    • 2004
  • The high frequency series resonant converter has been widely used for the non-contact power supply system with the large air gap and the increased leakage inductance of the non-contact transformer. However. the high frequency series resonant converter has the disadvantages of high voltage gain characteristics in the overall load range due to the large air gap and the circulating magnetizing current. In this paper, unit voltage gain is revealed in the proposed three-level series-parallel resonant converter. The results are verified on the simulation results and the 5kW experimental prototype.

  • PDF

Investigation on helix type labyrinth seal to minimize leakage flow of cryogen for rotating superconducting machines

  • Yubin Kim;Kihwan Kim;Seungcheol Ryu;Hojun Cha;Seokho Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제26권1호
    • /
    • pp.25-30
    • /
    • 2024
  • High-temperature superconducting rotors offer advantages in terms of output-to-weight ratio and efficiency compared to conventional phase conduction motors or generators. The rotor can be cooled by conduction cooling, which attaches a cryocooler, and by refrigerant circulation, which uses circulating liquid or gas neon, helium and hydrogen. Recent work has focused on environmental issues and on high-temperature superconducting motors cooled with liquid hydrogen that can be combined with fuel cells. However, to ensure smooth supply and return of the cryogenic cooling fluid, a cryogenic rotational coupling between the rotating and stationary parts is necessary. Additionally, the development of a sealing structure to minimize fluid leakage applicable to the coupling is essential. This study describes the design and performance evaluation of a non-contact sealing method, specifically a labyrinth seal, which avoids power loss and heat load caused by friction in contact sealing structures. The seal design incorporates a spiral flow path to reduce leakage using centrifugal force, and computational fluid dynamics (CFD) simulations were conducted to analyze the flow path and rotational speed. A performance evaluation device was configured and employed to evaluate the designed seal. The results of this study will be used to develop a cryogenic rotational coupling with supply and return flow paths for cryogenic applications.

열화상 이미지를 이용한 배전 설비 검출 및 진단 (Detection and Diagnosis of Power Distribution Supply Facilities Using Thermal Images)

  • 김주식;최규남;이형근;강성우
    • 대한안전경영과학회지
    • /
    • 제22권1호
    • /
    • pp.1-8
    • /
    • 2020
  • Maintenance of power distribution facilities is a significant subject in the power supplies. Fault caused by deterioration in power distribution facilities may damage the entire power distribution system. However, current methods of diagnosing power distribution facilities have been manually diagnosed by the human inspector, resulting in continuous pole accidents. In order to improve the existing diagnostic methods, a thermal image analysis model is proposed in this work. Using a thermal image technique in diagnosis field is emerging in the various engineering field due to its non-contact, safe, and highly reliable energy detection technology. Deep learning object detection algorithms are trained with thermal images of a power distribution facility in order to automatically analyze its irregular energy status, hereby efficiently preventing fault of the system. The detected object is diagnosed through a thermal intensity area analysis. The proposed model in this work resulted 82% of accuracy of detecting an actual distribution system by analyzing more than 16,000 images of its thermal images.