• Title/Summary/Keyword: Non-contact measuring instrument

Search Result 16, Processing Time 0.023 seconds

A Study on the Development of Measuring System for Extra Long Roller Using Non-contact Sensor (비접촉식 센서를 이용한 초장축 롤러 측정 장치 개발에 관한 연구)

  • Kim, Woong;Lee, Choon-Man;Lee, Mun-Jae;Park, Sung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.4
    • /
    • pp.33-39
    • /
    • 2010
  • Manufacturing accuracy of a precision instrument was essential to stability and efficiency of the product. Accordingly, geometrically accuracy management of precision instrument was very becoming the technique in order to design and manufacturing for machine. In this study, Measuring System is developed for extra long roller using non-contact sensor. Futhermore, It's studied by Geometric Tolerance. Exact roundness is obtained to Least Squares method from the reference circle of measured data. Measuring System is analyzed point of measurement and straightness of extra long roller is evaluated by FEM.

Measurement of Bangudae Rock Joint Using Non-adhesive, Non-contact Inclinometer Slope Laser Measuring System (비부착, 비접촉 방식의 계측기를 이용한 반구대암각화 암반 절리면의 계측)

  • Kim, Jae Hyun;Lee, Sang Ok;Chung, Kwang Yong;Han, Min Su
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.617-625
    • /
    • 2021
  • Daegokcheon Stream in Daegok-ri, Ulju-gun, is an area with a developed valley and bedrock from Gajisan Provincial Park to the confluence of the Taehwa River across the Yangsan Fault. To measure the rock of Bangudae petroglyphs, the mineralogical weathering, joints, and scours or cavities at the bottom were confirmed. The measurement was carried out for a short period of time on the joint of the bedrock on which the Bangudae petroglyphs were engraved. Compared to the measured value obtained using existing optical fiber (Ch4 150 ㎛), a displacement value of 300 ㎛ was obtained using the non-attached, non-contact type of measuring instrument. In the future, it is inferred that this instrument could be used for various cultural properties if the HSV-value suitable for illuminance and various measurement experiences are stored.

Development of Non-Adhesive, Non-Contact Inclinometer Slope Laser Measuring (ISLM) System and its Control Algorithm (레이저를 이용한 기울기 측정 장치 및 이의 제어 방법 개발)

  • Kim, Jae-Hyun;Lee, Seong-Min;Lee, Kihak;Choi, Woo-Suk;Baek, Seung-hoon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.3
    • /
    • pp.25-34
    • /
    • 2021
  • This study develops a new device system for measuring a slope of object with non-adhesive, non-contact and non-face-to-face, namely Inclinometer Slope Laser Measuring (ISLM), that is applicable in the field. This system includes cradle, laser, camera, and computer and the filming and is performed after laser projection at programmed intervals. After measuring the amount of displacement converted to numerical values, these values can then be transferred to the office using the selected data transmission method. The obtained results from the test carried out to verify the reliability of the ISLM system indicated that the ISLM system can measure with accurately level of 0.1mm/Pixel at 1m distance and when increasing the camera resolution, the precision might increase proportionally. Therefore, the proposed measure system may widely apply on-site for various constructions, especially, in the case of object with very high surface temperature where exhibits difficulty to directly measure the adjacent structures. However, due to the sensitive reaction to the illuminance, this method can be applied with caution at times of large changes in illuminance, such as at dawn and at dusk.

Development of Image Processing Technology for Interaction between Pantograph and Overhead Contact Wire (팬터그래프-전차선로 접촉부 영상처리 기술 개발)

  • Kim, Hyung-Jun;Park, Young;Cho, Yong-Hyeon;Cho, Chul-Jin;Kim, In-Chol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1084-1088
    • /
    • 2009
  • The measurement of dynamic stagger in electric railways is one of the key test parameters to increase speed and maintain safety in electric railways. This paper is introduces a non-contact optical-based measuring instrument of a catenary system in electric railways. The instrument is implemented by utilizing a CCD (Charge Coupled Device) camera installed on the roof of a vehicle for vision acquisition and image processing techniques including the Canny edge detector and the Hough transform to detect contact wires and calculate dynamic stagger. To check the validity of our approach for the intended application, we measured stagger of a overhead wire of a Korea Tilting Train (TTX). The non-contact optical-based measurement system proposed in this paper performs real-time stagger measurement of an activated high-voltage contact wire. By results of this paper, the instrument should be applied to assess performance and reliability of newly developed electric railway vehicles.

Development of an Automated Shaft Outside Diameter Measuring System (레이저 광학 장비와 컴퓨터를 이용한 자동측정 장치의 개발)

  • 최상민;이정주
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.197-199
    • /
    • 1986
  • To meet tight tolerance requirements of mass produced shafts which are subcomponents of automobile parts, an automated measuring system has been developed. The system comprises of a non-contact shaft diameter measuring instrument using laser, a feed mechanism of a step motor and ball screw and a personal computer. The system can determine pass-fail of the piece under test and also analyze data for statistical process control.

  • PDF

Development of Measurement System for Deflection of the Large-Size FPD (대면적 평판 디스플레이용 유리기판의 처짐 측정장치 개발)

  • Kim, Sook-Han;Kim, Tae-Sik;Lee, Eung-Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.4
    • /
    • pp.1-5
    • /
    • 2008
  • There is a need to enlarge the mother glass substrate in OLED to raise its productivity and to realize OLED TV. On the other hand, some difficulties may arise regarding the deflection of a large glass substrate during its handling operation due to its thinness $(0.5\sim0.7t)$, which is not even enough to allow it to stand its own mass. This thesis proposes a conceptual plan for the application of the clamping- and bending-end conditions to the glass substrate handler. To verify proposed plan, the non-contact 3 dimensional measuring instrument is developed. The composition of the 3 dimensional measuring instrument measures shape of the product using X-Y stage robot and laser distance sensor. X-Y stage robot and laser distance sensor are controlled by LabVIEW language. To calibrate measuring instrument, the direction conversion of the Euler angle was used. In order to confirm deflection of the glass substrate, the experiment was carried out at the bending end boundary condition and the proposed effect was verified.

  • PDF

Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System

  • Jovanovic, Ugljesa;Mancic, Dragan;Jovanovic, Igor;Petrusic, Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.904-910
    • /
    • 2017
  • This paper presents temperature measurement of solar photovoltaic modules using the custom-made system composed of an infrared temperature sensor and a microcontroller. The obtained measurement results are processed, displayed and stored on a PC using the custom-made virtual instrument. The proposed system overcomes some of the problems related to the contact sensor application, and at the same time offers accurate readings and better flexibility. The proposed system is especially suitable for applications where the cost is a limiting factor in the choice of measuring system. The conducted analysis and the obtained results have shown an excellent accuracy of the proposed system in comparison to a high quality thermal imaging camera used as the reference instrument.

Measurements of 3-D Deflection Characteristics of a Flexible Plate Levitated by Non-Contact Grippers Using SPIV Method (SPIV 기법을 이용한 비접촉 그리퍼에 의해 공중부양된 유연판의 3차원 변형 특성 측정)

  • Kim, Jaewoo;Kim, Joon Hyun;Lee, Yung Hoon;Sung, Jaeyong
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.54-62
    • /
    • 2021
  • This study has investigated the 3-D deflection characteristics of a flexible plate levitated by non-contact grippers using SPIV method. The measuring instrument consisted of a flexible plate located under four non-contact grippers and two cameras at the bottom of a transparent acrylic plate. Measurements were made on two materials (PVC and PC) for the plate with 50×50 cm2 area and 1 mm thickness. The deflection characteristics and flatness vary depending on the plate material, the gripper position and the air flow supplied to the gripper. For the material of PVC, the overall defection is convex. As the gripper position goes outward from the plate center, the upmost bending point also moves to the outside of the plate with the flatness increasing. However, the air flow rate does not affect the deflection pattern except for the small increase of flatness. For the material of PC, the shape of deflection changes from convex to concave as the gripper position goes out. The flatness is the highest at the point of transition from convex to concave, but the air flowrate has little effect on the flatness.

Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture (손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스)

  • Jang, Ik-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

Flood Runoff Measurements using Surface Image Velocimetry (표면영상유속계(SIV)를 이용한 홍수유출량 측정)

  • Kim, Yong-Seok;Yang, Sung-Kee;Yu, Kwon-Kyu;Kim, Dong-Su
    • Journal of Environmental Science International
    • /
    • v.22 no.5
    • /
    • pp.581-589
    • /
    • 2013
  • Surface Image Velocimetry(SIV) is an instrument to measure water surface velocity by using image processing techniques. Since SIV is a non-contact type measurement method, it is very effective and useful to measure water surface velocity for steep mountainous streams, such as streams in Jeju island. In the present study, a surface imaging velocimetry system was used to calculate the flow rate for flood event due to a typhoon. At the same time, two types of electromagnetic surface velocimetries (electromagnetic surface current meter and Kalesto) were used to observe flow velocities and compare the accuracies of each instrument. The comparison showed that for velocity distributions root mean square error(RMSE) was 0.33 and R-squared was 0.72. For discharge measurements, root mean square error(RMSE) reached 6.04 and R-squared did 0.92. It means that surface image velocimetry could be used as an alternative method for electromagnetic surface velocimetries in measuring flood discharge.