Proposition of Copper - Foil Magnetic Sensor for the Two-axis Remote Measurement of Bending Vibration of a Non-metallic Cylinder (비금속 배관에서의 원격 2축 굽힘 진동 측정을 위한 동박 패치형 자기 센서의 제안)

  • Kim, Jin-Ki;Han, Soon-Woo;Kim, Yoon-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.381-385
    • /
    • 2008
  • This paper suggests a non-contact sensor for measuring bending vibration of a non-metallic cylinder in two orthogonal directions simultaneously. Recent research shows that a solenoid can pick up bending vibrations of a nonmetallic cylinder based on the reversed Lorentz force mechanism if an electrically conductive patch is attached to the cylinder. In this work, pairs of specially designed patches are used to make two independent paths for the current induced by bending vibrations, which enables the measurement of bending vibrations along two orthogonal directions simultaneously. The working performance of the developed sensor was verified by using two accelerometers.

Precise Resistivity Measurement Independent Of Contact Resistance Influence And Its Applications

  • Kim, Dae-Hyun;Ryu, Hye-Yeon;Ji, Hyun-Jin;Lee, Jae-Woo;Kim, Gyu-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.146-147
    • /
    • 2007
  • A universal four-point contact measurement method, has an advantage of non-existence of contact resistance, is demonstrated by the experiments with carbon nanotubes and ZnO nanowire. Ti/Au and Pt are tried to compare the influence of contact resistance between two different metals. These metals are selected to make Ohmic contact and Schottky contact originated from their different work functions. For precise experiments, Ti/Au and Pt are separately evaporated to form double 'four-point contact electrodes' on CNTs or ZnO, and the voltage-current characteristics are measured. This method can be applied to universal resistivity measurement for nanotubes and nanowires.

  • PDF

Development of Image Processing Technology for Interaction between Pantograph and Overhead Contact Wire (팬터그래프-전차선로 접촉부 영상처리 기술 개발)

  • Kim, Hyung-Jun;Park, Young;Cho, Yong-Hyeon;Cho, Chul-Jin;Kim, In-Chol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1084-1088
    • /
    • 2009
  • The measurement of dynamic stagger in electric railways is one of the key test parameters to increase speed and maintain safety in electric railways. This paper is introduces a non-contact optical-based measuring instrument of a catenary system in electric railways. The instrument is implemented by utilizing a CCD (Charge Coupled Device) camera installed on the roof of a vehicle for vision acquisition and image processing techniques including the Canny edge detector and the Hough transform to detect contact wires and calculate dynamic stagger. To check the validity of our approach for the intended application, we measured stagger of a overhead wire of a Korea Tilting Train (TTX). The non-contact optical-based measurement system proposed in this paper performs real-time stagger measurement of an activated high-voltage contact wire. By results of this paper, the instrument should be applied to assess performance and reliability of newly developed electric railway vehicles.

The Development of Temperature Measurement System using Non-Contact Temperature Sensor Array (비접촉식 온도센서 어레이를 활용한 온도 계측시스템 개발)

  • Kim, Sung-Dae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2087-2092
    • /
    • 2015
  • Recently, use of the heat transferring machine and systems has been increasing in various industrial fields. A key technique for constructing such process is basically to measuring temperature directly to objects established on industrial plants. Particularly, a non-contact temperature measurement is very important to realize advanced heat transferring systems. This paper presents a new measurement methodology for temperature by using USN(ubiquitous sensor networks) technique including the microprocessor unit based ZigBee communication systems. This proposed system is made to be applied in monitoring systems for non-contact temperature measurement. We designed firmware based measurement systems whose main function is to save s series of temperature data sets and send it to main monitoring systems.

Nondestructive Measurement of Cheese Texture using Noncontact Air-instability Compensation Ultrasonic Sensors

  • Baek, In Suck;Lee, Hoonsoo;Kim, Dae-Yong;Lee, Wang-Hee;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.37 no.5
    • /
    • pp.319-326
    • /
    • 2012
  • Purpose: Cheese texture is an important sensory attribute mainly considered for consumers' acceptance. The feasibility of nondestructive measurements of cheese texture was explored using non-contact ultrasonic sensors. Methods: A novel non-contact air instability compensation ultrasonic technique was used for five varieties of hard cheeses to measure ultrasonic parameters, such as velocity and attenuation coefficient. Five texture properties, such as fracturability, hardness, springiness, cohesiveness, and chewiness were assessed by a texture profile analysis (TPA) and correlated with the ultrasonic parameters. Results: Texture properties of five varieties of hard cheese were estimated using ultrasonic parameters with regression analysis models. The most effective model predicted the fracturability, hardness, springiness, and chewiness, with the determination coefficients of 0.946 (RMSE = 21.82 N), 0.944 (RMSE = 63.46 N), 0.797 (RMSE = 0.06 ratio), and 0.833 (RMSE = 17.49 N), respectively. Conclusions: This study demonstrated that the non-contact air instability compensation ultrasonic sensing technique can be an effective tool for rapid and non-destructive determination of cheese texture.

Realization of Non-contact Sheet Resistance Measurement System for LCD using Eddy Current Probe (와전류탐침을 이용한 LCD용 비접촉식 면적저항 측정기의 구현)

  • 강신혁;최재훈황호정
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.617-620
    • /
    • 1998
  • In this paper we realized non-contact sheet resistance measurement system using eddy current. Proposed system is designed to meet the requirements which is necessary when dealing with conducting thin films on large area LCD panel. With several metals we could get lift-off curves which has the same trend as in principal. Especially in the region of high conductivity this system has more discriminating ability than 4-point probe system.

  • PDF

Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor (복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구)

  • Min, Se-Dong;Kim, Jin-Kwon;Shin, Hang-Sik;Yun, Young-Hyun;Lee, Chung-Keun;Lee, Jeong-Whan;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.

Analysis of Electrical Contact Resistance Model in Multi-Contact of Tribological Elements (트라이볼로지 기소의 멀티접촉에서 전기접촉저항 모델해석에 관한 연구)

  • 김청균
    • Tribology and Lubricants
    • /
    • v.12 no.4
    • /
    • pp.52-59
    • /
    • 1996
  • The results of the electrical contact conductivity of multi-contact spots accounting the surface roughness and the non-conductive films of different origins such as air, water, cutting oil, and machining oil are presented. The array of metal spheres compressed between two flat plates has been used for simulation of the contact behavior of multiple contact of solids, under normal loading. Measurement of electrical contact resistance has been made using the equipment providing the adequate accuracy in the range of micro Ohms. The data on electrical contact resistance have been compared with theoretical predictions using the multiple contact model of constriction resistance. The effect of single spot number and array on conductivity of contact has been evaluated. The results of the experiments show that the contact resistance are closely related to the number of loading cycles, form of surface roughness, and presence of non-conductive films that reduce the size of the real electrical contact spots.

A Study on Curvature Radius Measurement Using Laser Interferometer (레이저 간섭계를 이용한 곡률반경 측정에 관한 연구)

  • Lee Ji Yong;Kim Min Ju;Lee Seung Soo;Jeon Eon Chan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.34-40
    • /
    • 2004
  • This paper presents studies on curvature radius measurement using the laser interferometer. It is a general practice to measure to $10^{-10}$m in length with the recent improvement and innovations in measurement technology and the processor used. The measurement methods can generally be categorized as these two: the contactual method and non-contactual method; and in this study, we will find ways to lower the cost for a CMM, or a coordinate measurement machine, and try to find an alternative. Furthermore, we will discuss some of the ways to improve the non-contactual measurement methods-optical interferometer method and the optical triangulation method. We will measure an object using a laser distance measuring device and Set the Point-contact result with the ball-bearing type and line-contact result with the bearing type, to decide on which probe type will be used.

Evaluation of Oxygen Permeability of Soft Contact Lenses Based on Thickness (두께 기준에 따른 소프트 콘택트렌즈의 산소투과성 평가)

  • Yu, Dong-Sik;Moon, Byeong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2157-2163
    • /
    • 2009
  • The oxygen permeability of a soft contact lens is an important parameter for determining corneal health when considering the physiological response of the eye. The aim of this study is to evaluate the oxygen permeability of soft contact lenses based on thickness, using the polarographic method. The thickness of lens was measured using contact and non-contact method. To assess accuracy and reliability, the Bland-Altman plot was used. The reliability was high for the oxygen permeability based on center thickness measured by contact method, whereas the accuracy was high for the oxygen permeability based on center thickness measured by non-contact method. These results indicate that the permeability characteristics were variable according to the measurement and criteria of thickness of soft contact lenses and the measurement of soft contact lenses by non-contact method was more reasonable. Thus, contact lens practitioners should consider some basic differences between methodologies when interpreting or quoting oxygen performance data.