• Title/Summary/Keyword: Non-conformity

Search Result 108, Processing Time 0.03 seconds

The U.S. Courts' Interpretation of Foreign Arbitral Awards Under the NY Convention (뉴욕협약상 외국중재판정에 대한 미국법원의 해석)

  • Ha Choong-Lyong;Park Won-Hyung
    • Journal of Arbitration Studies
    • /
    • v.16 no.2
    • /
    • pp.121-150
    • /
    • 2006
  • Under the New York Convention, parties can petition the courts of the United States to confirm foreign arbitral awards. Although there is no definition in the Convention for 'non-domestic' awards, in the United States, federal and state courts read the Convention broadly and interpret this as permitting the enforcing authority to supply its own definition of 'non-domestic' in conformity with its own domestic law. There are a number of federal cases on this point. The court preferred this broad construction of 'non-domestic' awards because it comported with the intended purpose of the Convention, which was entered into to encourage the recognition and enforcement of international arbitral awards. This means that in applying the New York Convention, U.S. courts have responded to the underlying spirit rather than the technical letter of the Convention. In brief, the New York Convention has much broader application in the United States. It is applicable not only to awards rendered outside of the United States, but also to non-domestic awards rendered within United States. As this article suggests, the general attitude towards foreign awards is more pro-enforcement in the United States, whether the award is rendered in favor of the American party or in favor of the foreign party.

  • PDF

Dosimetric Comparison of Three Dimensional Conformal Radiation Radiotherapy and Helical Tomotherapy Partial Breast Cancer (유방암 환자의 3D-CRT, TOMO 방법에 따른 선량 분포 평가)

  • Kim, Dae-Woong;Kim, Jong-Won;Choi, Yun-Kyeong;Kim, Jung-Soo;Hwang, Jae-Woong;Jeong, Kyeong-Sik;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.11-15
    • /
    • 2008
  • Purpose: The goal of radiation treatment is to deliver a prescribed radiation dose to the target volume accurately while minimizing dose to normal tissues. In this paper, we comparing the dose distribution between three dimensional conformal radiation radiotherapy (3D-CRT) and helical tomotherapy (TOMO) plan for partial breast cancer. Materials and Methods: Twenty patients were included in the study, and plans for two techniques were developed for each patient (left breast:10 patients, right breast:10 patients). For each patient 3D-CRT planning was using pinnacle planning system, inverse plan was made using Tomotherapy Hi-Art system and using the same targets and optimization goals. We comparing the Homogeneity index (HI), Conformity index (CI) and sparing of the organs at risk for dose-volume histogram. Results: Whereas the HI, CI of TOMO was significantly better than the other, 3D-CRT was observed to have significantly poorer HI, CI. The percentage ipsilateral non-PTV breast volume that was delivered 50% of the prescribed dose was 3D-CRT (mean: 40.4%), TOMO (mean: 18.3%). The average ipsilateral lung volume percentage receiving 20% of the PD was 3D-CRT (mean: 4.8%), TOMO (mean: 14.2), concerning the average heart volume receiving 20% and 10% of the PD during treatment of left breast cancer 3D-CRT (mean: 1.6%, 3.0%), TOMO (mean: 9.7%, 26.3%) Conclusion: In summary, 3D-CRT and TOMO techniques were found to have acceptable PTV coverage in our study. However, in TOMO, high conformity to the PTV and effective breast tissue sparing was achieved at the expense of considerable dose exposure to the lung and heart.

  • PDF

Numerical simulation of shear mechanism of concrete specimens containing two coplanar flaws under biaxial loading

  • Sarfarazi, Vahab;Haeri, Hadi;Bagheri, Kourosh
    • Smart Structures and Systems
    • /
    • v.22 no.4
    • /
    • pp.459-468
    • /
    • 2018
  • In this paper, the effect of non-persistent joints was determined on the behavior of concrete specimens subjected to biaxial loading through numerical modeling using particle flow code in two dimensions (PFC2D). Firstly, a numerical model was calibrated by uniaxial, Brazilian and triaxial experimental results to ensure the conformity of the simulated numerical model's response. Secondly, sixteen rectangular models with dimension of 100 mm by 100 mm were developed. Each model contains two non-persistent joints with lengths of 40 mm and 20 mm, respectively. The angularity of the larger joint changes from $30^{\circ}$ to $90^{\circ}$. In each configuration, the small joint angularity changes from $0^{\circ}$ to $90^{\circ}$ in $30^{\circ}$ increments. All of the models were under confining stress of 1 MPa. By using of the biaxial test configuration, the failure process was visually observed. Discrete element simulations demonstrated that macro shear fractures in models are because of microscopic tensile breakage of a large number of bonded discs. The failure pattern in Rock Bridge is mostly affected by joint overlapping whereas the biaxial strength is closely related to the failure pattern.

A Study on the Law of Non-performance of International Sales Contract under the Contract Law of The People's Republic of China (중국계약법(中國契約法)상 무역계약불이행(貿易契約不履行)관련 규정(規定)의 연구(硏究))

  • Ahn, Yeong-Tae
    • International Commerce and Information Review
    • /
    • v.8 no.1
    • /
    • pp.243-257
    • /
    • 2006
  • This study is to introduce the Chinese Contract Law against non-performance of the contract and to solve the wide range of problems involving to executing the trading contract. The parties' liability for the period of performance, the place of performance, the failure to deliver conforming goods together with it's nature of the lack of conformity, and the methods of compensation against damages and the force majeure clauses application. Those issues affect directly to commercial transactions in international business. The focus is more on the interrelationship of private individuals in its trade and on aiming to remove the legal obstacles from the Chinese Contract Law to freely flow of international trade. Reference may include foreign corrupt practices, Conventions on Contracts for the International Sale of Goods and Laws of England, France, and Japan. This study has brought the efforts of these issues in the full spectrum of performance and with concentrations on effectiveness to avoid the different viewpoints of the general principles of CISG and commercial practice founded pre-eminently. This study, in presenting the legal framework, will contribute to a better understanding of the purpose of rules of Chinese Contract -Law as they interact to the benefit of the parties involved in international trade transactions. The writer believes that a problem-oriented approach and the concentration as outlined above would offer a different perspective for law faculty teaching in this area and hope that this study can be sufficiently diverse to satisfy many of those views.

  • PDF

A Study on Usefulness of Clinical Application of Metal Artifact Reduction Algorithm in Radiotherapy (방사선치료 시 Metal artifact reduction Algorithm의 임상적용 유용성평가)

  • Park, Ja Ram;Kim, Min Su;Kim, Jeong Mi;Chung, Hyeon Suk;Lee, Chung Hwan;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The tissue description and electron density indicated by the Computed Tomography(CT) number (also known as Hounsfield Unit) in radiotherapy are important in ensuring the accuracy of CT-based computerized radiotherapy planning. The internal metal implants, however, not only reduce the accuracy of CT number but also introduce uncertainty into tissue description, leading to development of many clinical algorithms for reducing metal artifacts. The purpose of this study was, therefore, to investigate the accuracy and the clinical applicability by analyzing date from SMART MAR (GE) used in our institution. Methode: and material: For assessment of images, the original images were obtained after forming ROIs with identical volumes by using CIRS ED phantom and inserting rods of six tissues and then non-SMART MAR and SMART MAR images were obtained and compared in terms of CT number and SD value. For determination of the difference in dose by the changes in CT number due to metal artifacts, the original images were obtained by forming PTV at two sites of CIRS ED phantom CT images with Computerized Treatment Planning (CTP system), the identical treatment plans were established for non-SMART MAR and SMART MAR images by obtaining unilateral and bilateral titanium insertion images, and mean doses, Homogeneity Index(HI), and Conformity Index(CI) for both PTVs were compared. The absorbed doses at both sites were measured by calculating the dose conversion constant (cCy/nC) from ylinder acrylic phantom, 0.125cc ionchamber, and electrometer and obtaining non-SMART MAR and SMART MAR images from images resulting from insertions of unilateral and bilateral titanium rods, and compared with point doses from CTP. Result: The results of image assessment showed that the CT number of SMART MAR images compared to those of non-SMART MAR images were more close to those of original images, and the SD decreased more in SMART compared to non-SMART ones. The results of dose determinations showed that the mean doses, HI and CI of non-SMART MAR images compared to those of SMART MAR images were more close to those of original images, however the differences did not reach statistical significance. The results of absorbed dose measurement showed that the difference between actual absorbed dose and point dose on CTP in absorbed dose were 2.69 and 3.63 % in non-SMRT MAR images, however decreased to 0.56 and 0.68 %, respectively in SMART MAR images. Conclusion: The application of SMART MAR in CT images from patients with metal implants improved quality of images, being demonstrated by improvement in accuracy of CT number and decrease in SD, therefore it is considered that this method is useful in dose calculation and forming contour between tumor and normal tissues.

  • PDF

The Evaluation of Non-Coplanar Volumetric Modulated Arc Therapy for Brain stereotactic radiosurgery (뇌 정위적 방사선수술 시 Non-Coplanar Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Doo Sang;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.9-16
    • /
    • 2018
  • Purpose : Brain Stereotactic Radiosurgery can treat non-invasive diseases with high rates of complications due to surgical operations. However, brain stereotactic radiosurgery may be accompanied by radiation induced side effects such as fractionation radiation therapy because it uses radiation. The effects of Coplanar Volumetric Modulated Arc Therapy(C-VMAT) and Non-Coplanar Volumetric Modulated Arc Therapy(NC-VMAT) on surrounding normal tissues were analyzed in order to reduce the side effects caused fractionation radiation therapy such as head and neck. But, brain stereotactic radiosurgery these contents were not analyzed. In this study, we evaluated the usefulness of NC-VMAT by comparing and analyzing C-VMAT and NC-VMAT in patients who underwent brain stereotactic radiosurgery. Methods and materials : With C-VMAT and NC-VMAT, 13 treatment plans for brain stereotactic radiosurgery were established. The Planning Target Volume ranged from a minimum of 0.78 cc to a maximum of 12.26 cc, Prescription doses were prescribed between 15 and 24 Gy. Treatment machine was TrueBeam STx (Varian Medical Systems, USA). The energy used in the treatment plan was 6 MV Flattening Filter Free (6FFF) X-ray. The C-VMAT treatment plan used a half 2 arc or full 2 arc treatment plan, and the NC-VMAT treatment plan used 3 to 7 Arc 40 to 190 degrees. The angle of the couch was planned to be 3-7 angles. Results : The mean value of the maximum dose was $105.1{\pm}1.37%$ in C-VMAT and $105.8{\pm}1.71%$ in NC-VMAT. Conformity index of C-VMAT was $1.08{\pm}0.08$ and homogeneity index was $1.03{\pm}0.01$. Conformity index of NC-VMAT was $1.17{\pm}0.1$ and homogeneity index was $1.04{\pm}0.01$. $V_2$, $V_8$, $V_{12}$, $V_{18}$, $V_{24}$ of the brain were $176{\pm}149.36cc$, $31.50{\pm}25.03cc$, $16.53{\pm}12.63cc$, $8.60{\pm}6.87cc$ and $4.03{\pm}3.43cc$ in the C-VMAT and $135.55{\pm}115.93cc$, $24.34{\pm}17.68cc$, $14.74{\pm}10.97cc$, $8.55{\pm}6.79cc$, $4.23{\pm}3.48cc$. Conclusions : The maximum dose, conformity index, and homogeneity index showed no significant difference between C-VMAT and NC-VMAT. $V_2$ to $V_{18}$ of the brain showed a difference of at least 0.5 % to 48 %. $V_{19}$ to $V_{24}$ of the brain showed a difference of at least 0.4 % to 4.8 %. When we compare the mean value of $V_{12}$ that Radione-crosis begins to generate, NC-VMAT has about 12.2 % less amount than C-VMAT. These results suggest that if NC-VMAT is used, the volume of $V_2$ to $V_{18}$ can be reduced, which can reduce Radionecrosis.

  • PDF

Controversy and Guideline Suggestion Surrounding Fake News in the Digital Media Age (가짜뉴스(Fake News) 현황분석을 통해 본 디지털매체 시대의 쟁점과 뉴스콘텐츠 제작 가이드라인)

  • Kwon, Mahnwoo;Jun, Yong Woo;Im, Hajin
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.11
    • /
    • pp.1419-1426
    • /
    • 2015
  • Distinguishing border between news and advertising is disappearing. Traditional journalism considered editorial part deals news and ad part handle commercial messages. But now this classification is meaningless. Current news consumers do not separate advertising content and non-advertising content. In Korea, making fake news or paid news pages is becoming social problem. Fake news uses various camouflages to pretend to be real news. This paper descriptively analyzed Korean fake news cases and suggested some guidelines for publishing news. We analyzed 3 major newspaper web sites from July to September, 2014. These three newspapers publish section pages everyday containing fake news or sponsored news. Totally more than one thousand articles were selected for content analysis. We coded the numbers of fake news, day of the week, the rate of sponsored news, average fake news publication number per pages, the conformity between news and advertising, and the type of fake news. We also coded the number of sponsored news article in day sections. We used method of comparing the advertising contents and news articles. As a result, 24.8% of news article were published for the advertising sponsors. Advertorial or fake news were sometimes arranged same pages the same day. We coded the conformity between same advertising and news content. More than 60 percent (60.9%) of fake news match with their sponsors. PR style of fake news is top and advertising type of fake news is the lowest.

A Study on the Consumer's Purchasing Motives toward Casual Hanbok - in the areas of Pusan - (생활한복의 구매동기에 관한 연구 -부산지역을 중심으로-)

  • 최은경
    • Journal of the Korean Society of Costume
    • /
    • v.45
    • /
    • pp.71-84
    • /
    • 1999
  • This study was to identify the dimensions of consumer's purchasing motives and purchasing delay reasons toward casual hanbok. Other objective was to examine relationship between these variables and future purchasing intention. Th 22 purchasing motive questions and 19 purchasing delay reasons were selected through the result of self-questionnaire analysis. 302 purchaser and 297 consumers who delay for particular reasons in Pusan responsed to the second questionnaire of purchasing motives and purchasing delay reasons toward casual Hanbok. The results as follows: 1. For factor analysis 22 purchasing motive questions were subjected to the principle component analysis with orthogonal rotation after extraction of 6 major factors. Six dimensions are consciousness of nation goodness of design conformity with fashion charming apperance relaxation fo body and mind nation goodness of design conformity with fashion charming appearance relaxation of body and mind and pursuit of individuality. These factors explained 62.0% of total variables. 2. Consumer's purchasing motives such as consciousness of nation goodness of design charming appearance and relaxation of body and mind has predicting power to the re-purchasing intention of casual hanbok 3. For factor analysis 19 delay reason question were subjected to the principle component analysis with orthogonal rotation after extraction of 5 major factors. Five dimensions are non-fitness for occasion and body shape unsatisfaction with design unsatisfaction with price need of information search for better product and preference for traditional hangok. These factors explained 60.4% of total variables. 4. Delay reasons of unsatisfaction with design and price were positively related to the future purchasing intention. This delay reason is caused by forces external to the consumer and the consumer has engaged in information search. This result explained this type of consumer has the strong future purchasing intention.

  • PDF

Characteristics of LDPE resin film depending on RP contents (적인 함유량에 따른 LDPE 수지 film의 특성연구)

  • JO, Dong-Soo;Noh, Young-Tai;Park, Byung-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6655-6665
    • /
    • 2015
  • Due to tightened environmental regulations on halogen type flame retardants, the portions of those based on phosphorous compounds that are non-halogen type is rising. When producing functional film, the physical and thermal properties become distinctly different depending on the amount of Red-phosphorus(RP) addition which causes flame resistance. The physical properties of resin fall in big scale when too much flame retardants are added, and it is hard to be applied to functional films such as shrink or anticorrosive film. The purpose of this research is to study the effects on mechanical, physical, and other properties of RP-LDPE films by changing the RP-MB contents. The LDPE film used for this study was produced through blow-type injection molding. The flame resistance was VTM-0, and the tear resistance showed inverse trends of MD and TD. Contraction percentage showed no relationship with the amount of RP content, but the anti-corrosive property showed 0.05 % better result than the national anti-corrosion shrink film reliability standard.

A Study on lung dose of Intensity modulated and volumetric modulated arc therapy plans using restricted angle of Non-small cell lung cancer (비소세포 폐암의 제한된 각도를 이용한 세기변조와 용적변조회전 방사선치료계획의 폐 선량에 관한 연구)

  • Yeom, Misuk;Lee, Woosuk;Kim, Daesup;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • Purpose : For non-small cell lung cancer, if the treatment volume is large or the total lung volume is small, and the tumor is located in midline of patient's body, total lung dose tends to increase due to tolerance dose of spinal cord. The purpose of this study is to compare and evaluate the total lung dose of three dimensional conformal radiotherapy(3D CRT), intensity modulated radiotherapy(IMRT) and volumetric modulated arc therapy(VMAT) using restricted angle for non-small cell lung cancer patients. Materials and Methods : The treatment plans for four patients, being treated on TrueBeam STx($Varian^{TM}$, USA) with 10 MV and prescribed dose of 60 Gy in 30 fractions, 3D CRT, restricted angle IMRT and VAMT radiotherapy plans were established. Planning target volume(PTV), dose to total lung and spinal cord were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV, $V_{30}$, $V_{20}$, $V_{10}$, $V_5$, mean dose for total lung and maximum dose for spinal cord was assessed. Results : Average value of CI, HI and PCI for PTV was $0.944{\pm}0.009$, $1.106{\pm}0.027$, $1.084{\pm}0.016$ respectively. $V_{20}$ values from 3D CRT, IMRT and VMAT plans were 30.7%, 20.2% and 21.2% for the first patient, 33.0%, 29.2% and 31.5% for second patient, 51.3%, 34.3% and 36.9% for third patient, finally 56.9%, 33.7% and 40.0% for the last patient. It was noticed that the $V_{20}$ was lowest in the IMRT plan using restricted angle. Maximum dose for spinal cord was evaluated to lower than the tolerance dose. Conclusion : For non-small cell lung cancer, IMRT with restricted angle or VMAT could minimize the lung dose and lower the dose to spinal cord below the tolerance level. Considering PTV coverage and tolerance dose to spinal cord, it was possible to obtain IMRT plan with smaller angle and this could result in lower dose to lung when compared to VMAT.