• Title/Summary/Keyword: Non-coated

Search Result 590, Processing Time 0.029 seconds

Surface Characteristics and Biocompatibility of MoS2-coated Dental Implant (MoS2 코팅된 치과용 임플란트의 표면특성과 생체적합성)

  • Min-Ki Kwon;Jun-Sik Lee;Mi Eun Kim;Han-Cheol Choe
    • Corrosion Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.72-81
    • /
    • 2024
  • The Ti-6Al-4V alloy is widely used as an implant material due to its higher fatigue strength and strengthto-weight ratio compared to pure titanium, excellent corrosion resistance, and bone-like properties that promote osseointegration. For rapid osseointegration, the adhesion between the titanium surface and cellular biomolecules is crucial because adhesion, morphology, function, and proliferation are influenced by surface characteristics. Polymeric peptides and similar coating technologies have limited effectiveness, prompting a demand for alternative materials. There is growing interest in 2D nanomaterials, such as MoS2, for good corrosion resistance and antibacterial, and bioactive properties. However, to coat MoS2 thin films onto titanium, typically a low-temperature hydrothermal synthesis method is required, resulting in the synthesis of films with a toxic 1T@2H crystalline structure. In this study, through high-temperature annealing, we transformed them into a non-toxic 2H structure. The implant coating technique proposed in this study has good corrosion resistance and biocompatibility, and antibacterial properties.

Transport behavior of a surfactant tracer(CPC) with Langmuir type adsorption isotherm on NAPL-water interface in a homogeneous porous medium (NAPL-물 계면에서 Langmuir형 흡착특성을 보이는 계면추적자(CPC)의 다공성 균질매질내 유동특성)

  • 김헌기;문희수;이상훈
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.3-13
    • /
    • 2001
  • It has been known that nonlinear characteristics of sorption affect the transport behavior of water soluble pollutants in soils. However detailed experimental studies have not been performed to verify the effect of non-linearity of adsorption isotherm on transport of chemicals in porous media. In this research, the distortion of breakthrough curves of a cationic surfactant (cetylpyridinium chloride, CPC) in a engineered stainless steel column packed with glass beads were investigated. Glass beads with about 110 $\mu\textrm{m}$diameter coated with a thin n-decane film were used as the media providing the sorption surface for CPC. The CPC adsorption isotherm on the surface of n-decane from aqueous solution was a typical Langmuir type. The breakthrough curve of CPC using step Input showed a late breakthrough on the front side and early breakthrough on the back side accordance to the shape of the isotherm. The retardation factor of CPC was found to be a strong function of the input concentration, which also a manifestation of the non-linearity of the isotherm. The retardation factors for the CPC with step input agreed with those of pulse input that the maximum concentrations are controlled to be the same as the step input concentrations. This results support the validity of the unproven field practices of using hydrogeotracers with non-linear adsorption isotherms to determine the hydrogeological parameters, e.g., NAPL saturation, air-water or NAPL-water interfacial areas.

  • PDF

High-Speed Cu Filling into TSV and Non-PR Bumping for 3D Chip Packaging (3차원 실장용 TSV 고속 Cu 충전 및 Non-PR 범핑)

  • Hong, Sung-Chul;Kim, Won-Joong;Jung, Jae-Pil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.4
    • /
    • pp.49-53
    • /
    • 2011
  • High-speed Cu filling into a through-silicon-via (TSV) and simplification of bumping process by electroplating for three dimensional stacking of Si dice were investigated. The TSV was prepared on a Si wafer by deep reactive ion etching, and $SiO_2$, Ti and Au layers were coated as functional layers on the via wall. In order to increase the filling rate of Cu into the via, a periodic-pulse-reverse wave current was applied to the Si chip during electroplating. In the bumping process, Sn-3.5Ag bumping was performed on the Cu plugs without lithography process. After electroplating, the cross sections of the vias and appearance of the bumps were observed by using a field emission scanning electron microscope. As a result, voids in the Cu-plugs were produced by via blocking around via opening and at the middle of the via when the vias were plated for 60 min at -9.66 $mA/cm^2$ and -7.71 $mA/cm^2$, respectively. The Cu plug with a void or a defect led to the production of imperfect Sn-Ag bump which was formed on the Cu-plug.

A Comparative Study on the Local Transmittance Homogeneity of the Ocular Lens (안경 렌즈의 국소적 투과율 균일도 비교 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Jang, Yun-Seog;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.471-476
    • /
    • 2015
  • Purpose: We have analyzed the transmittance distribution of various ocular lenses using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The local transmittance of the laser which is focused on the surface of the spectacle lens was measured by using the photo-detector, lock-in amplifier and motorized-stage. 25 multi-coated lenses with non-tinted of 5 groups and 45 multicoated lenses with tinted of 9 groups were analyzed as a sample respectively. Results: Average and deviation of local transmittance for nontinted lenses were measured almost uniformly with various refractive index and coating. However, deviation of transmittance of for tinted lenses was analyzed as about 3.7 times larger than that of non-tinted lenses. Inhomogeneity of local transmittance of for tinted lenses was also analyzed as about 3.1 times larger than that of non-tinted lenses. Conclusions: We could analyze that standard deviation of transmittance and inhomogeneity of local transmittance of for tinted lenses is larger than that of non-tinted lenses using the local transmittance microscope. These analysis using local transmittance microscope can be utilized as a way to evaluate lens performance and improve optical homogeneity.

Automotive Pre-primed Coatings with Automotive Structural Adhesive for Non-weldable Binding Process (자동차 구조용 접착제를 이용한 자동차용 Pre-primed 도료의 비용접식 접합공정 적용)

  • Moon, Je-Ik;Lee, Yong-Hee;Kim, Hyun-Joong;Noh, Seung Man;Nam, Joon Hyun;Kim, Min-Su;Kim, Jun-Ki;Kim, Jong-Hoon
    • Journal of Adhesion and Interface
    • /
    • v.12 no.3
    • /
    • pp.99-104
    • /
    • 2011
  • Currently, automotive pre-primed coatings has been developed to overcome environmental regulations and to reduce manufacturing cost in automotive industry. By these reasons, an automotive pre-primed system has been investigated to remove the wash and pre-treatment process using a roll coating application. It is required to develop non-weldable pre-primed system for automotive structural adhesives, because pre-primed sheet coated with organic compounds is hard to be assembled by welding process. Primer 1 (polyester type) and primer 2 (urethane type) were designed to satisfy flexibility and formability for non-weldable pre-primed system. According to the results of physical property test of the primers, adhesion test such as single-lap shear test and T-peel test, primer 1 (polyester type) had better physical properties such as pencil hardness, solvent resistance, flexibility and adhesion with automotive adhesive than that of primer 2 (polyurethane type). In addition, the possibility of the non-weldable pre-primed system was applicable to automotive assembly process in place of welding process.

Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy (화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가)

  • Lee, Chan Young;Lee, Sang Hun;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • In this study, both evaluations by visual imaging for exterior view of coating and by EIS were executed for epoxy primer coated specimens deteriorated by accelerated test, and comparison and analysis were carried out for 2 evaluation methods. In the comparison between total damaged area ratio acquired by image processing method and deterioration point, higher deterioration points were appeared for rusted specimens than for non-rusted specimens. It is attributed that deterioration point per unit area ratio given for rust is higher than for peeling. In the comparison between total damaged area ratio and EIS result, impedance of coating was largely decreased as about TEX>$10^4{\Omega}{\cdot}cm^2$ or less when rust area ratio is more than about 0.1%, and blistering area ratio is more than about 3%. Charge transfer resistance ($R_{ct}$) and double layer capacitance ($C_{dl}$) values were appeared for all specimens except 2 ones, which shows that water is accumulated and steel substrate is corroded at coated film-steel interface. In the comparison between deterioration point and EIS result, more than 10 points as deterioration point were given for specimens of below $10^6{\Omega}{\cdot}cm^2$ of impedance at low frequency. For specimens deteriorated by NORSOK cyclic test, impedance was lowest of all, though deterioration point was not high. It is thought to be attributed that coating system and accelerated deterioration condition of cyclic tested specimens were different from those of main specimens. From the result, it is thought that coating resistance can be relatively more decreased than deterioration degree estimated from exterior view under more severe corrosion environment or in the present of more complex deterioration factors.

Design of Discriminant Function for White and Yellow Coating with Multi-dimensional Color Vectors (다차원 컬러벡터 기반 백태 및 황태 분류 판별함수 설계)

  • Lee, Jeon;Choi, Eun-Ji;Ryu, Hyun-Hee;Lee, Hae-Jung;Lee, Yu-Jung;Park, Kyung-Mo;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.2 s.20
    • /
    • pp.47-52
    • /
    • 2007
  • In Oriental medicine, the status of tongue is the important indicator to diagnose one's health, because it represents physiological and clinicopathological changes of inner parts of the body. The method of tongue diagnosis is not only convenient but also non-invasive, therefore, tongue diagnosis is one of the most widely used in Oriental medicine. But tongue diagnosis is affected by examination circumstances a lot. It depends on a light source, degrees of an angle, doctor's condition and so on. So it is not easy to make an objective and standardized tongue diagnosis. As part of way to solve this problem, in this study, we tried to design a discriminant function for white and yellow coating with multi-dimensional color vectors. There were 62 subjects involved in this study, among them 48 subjects diagnosed as white-coated tongue and 14 subjects diagnosed as yellow-coated tongue by oriental doctors. And their tongue images were acquired by a well-made Digital Tongue Diagnosis System. From those acquired tongue images, each coating section were extracted by oriental doctors, and then mean values of multi -dimensional color vectors in each coating section were calculated. By statistical analysis, two significant vectors, R in RGB space and H in HSV space, were found that they were able to describe the difference between white coating section and yellow coating section very well. Using these two values, we designed the discriminant function for coating classification and examined how good it works. As a result, the overall accuracy of coating classification was 98.4%. We can expect that the discriminant function for other coatings can be obtained in a similar way. Furthermore, if an automated segmentation algorithm of tongue coating is combined with these discriminant functions, an automated tongue coating diagnosis can be accomplished.

  • PDF

Performance assessment of Magnesium Bipolar Plates for Light Weight PEM Fuel Cell (PEM 연료전지 경량화를 위한 마그네슘 분리판의 성능평가)

  • Park, To-Soon;Lee, Dong-Woo;Kim, Kyung-Hwan;Kwon, Se-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.12
    • /
    • pp.1063-1069
    • /
    • 2012
  • In present paper, we used magnesium alloy having a lower density and higher electrical conductivity for bipolar plate to reduce the weight of PEM fuel cell. The silver was coated to prevent corrosion and form passivation film on the metal surface with sputtering. In acid proof evaluation for setting optimal coating conditions, the homogeneity of coating thickness was improved by coating with the thickness of 3 ${\mu}m$ which not indicated any micro cracks and the temperature $180^{\circ}C$. The performance test and evaluation based on the clamping pressure and channel depth to determine the configuration of bipolar plate for assembling single cell was implemented. And then we assembled single cell with this bipolar plate and implemented the performance test to ensure and compare the current-voltage performance followed as several factors such as coating or non-coating, the change of clamping pressure, the change of channel depth, etc. As these results, the maximum power density of single cell with the coated bipolar plate was 192 $mW/cm^2$ and it was confirmed that the power density per unit mass was better than existing metal bipolar plate.

Effects of Application of Latex Coated Urea on Yield and N-Use Efficiency of the Direct Seeding Rice on Dry Paddy Field in the Year of High Temperature (Latex 피복요소시용(被覆尿素施用)과 고온(高溫)이 건답직파(乾畓直播) 벼의 질소이용효율(窒素利用效率)과 수량(收量)에 미치는 영향)

  • Yoo, Chul-Hyun;Shin, Bog-Woo;Jeong, Ji-Ho;Kang, Seung-Weon;Han, Sang-Soo;Kim, Seong-Jo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.4
    • /
    • pp.324-329
    • /
    • 1998
  • To investigate the changes of $NH_4-N$ in soil, nitrogen uptake by rice plant, nitrogen use efficiency and rice yield by the application of Latex Coated Urea(LCU) on direct seeding rice, rice was planted on paddy field, Jeonbuk series at the Honam area, from 1996 to 1997. Nitrogen in LCU applied as basal dressing in whole layer was dissolved almost untill non-productive stage. Thus, nitrogen deficiency symptom appeared and N in shoot was 1.75% showing 28.1 of SPAD value at heading stage. However percentage recovery of fertilizer N was higher in LCU than with urea application. Top dressing of urea at panicle initiation stage in addition to basal dressing of LCU, increased rice yield by 9%. Conventional split application of urea on the surface decreased the percentage recovery of fertilizer N to 56.9% of whole layer application plot.

  • PDF

A Study on the Optimization of Active Material and Preparation of Granular Adsorbent of Metal Oxide-based Adsorbent for Adsorption of Hydrogen Sulfide (H2S) (황화수소(H2S) 흡착을 위한 금속산화물 기반 흡착제의 활성물질 최적화 및 입상형 흡착제 제조에 대한 연구)

  • Choi, Sung Yeol;Han, Dong Hee;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.460-465
    • /
    • 2019
  • In this study, the optimization of active materials and the preparation of particulate adsorbents for the application of metal oxide-based adsorbents for the treatment of $H_2S$, an air pollutant and odorant, occurred in various industrial facilities were investigated. The adsorbents were prepared by using $TiO_2$, which has a high physicochemical stability and relatively high specific surface area among metal oxides and also by different kinds and contents of active materials. The correlation between the physicochemical property and adsorption performance of the adsorbents confirmed that the adsorbent containing KI, which is a typical alkali metal among the active metals, showed the highest adsorption performance. The relationship between the contents and the adsorption performance was non-proportional, but a volcano plot. From XRD, SEM and BET analyses, it was confirmed that the active material was exposed to the surface above a certain amount and also the adsorption performance was the best when the specific surface area and pore volume were $40{\sim}100m^2/g$ and $0.1{\sim}0.3cm^3/g$, respectively. For practical application, the adsorbent was granulated or coated on a ceramic support. It was also confirmed that the adsorbent showed high adsorption performance when the adsorbent was coated on the ceramic rather than that of the granulated support.