• Title/Summary/Keyword: Non-Point Sources (NPS)

Search Result 29, Processing Time 0.022 seconds

Effect of Pollutants Control Measures in So-oak Watershed on the Control of Algae Growth in Daecheong Reservoir (소옥천 유역의 오염제어 대책에 따른 대청호 조류저감 효과 분석)

  • Park, Hyung Seok;Yoon, Sung Wan;Chung, Se Woong;Hwang, Hyun Sik
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.4
    • /
    • pp.248-260
    • /
    • 2016
  • This study was aimed to assess the effect of diverse pollutants control measures suggested in the Chuso basin and its upstream of So-oak stream watershed where are the most concerned areas on the control of algal bloom occurring in Daecheong Reservoir. The control measures were classified as watershed measures and in-reservoir measures, and their effects were simulated using a two-dimensional hydrodynamic and water quality model. The watershed measures were made up of 1) point sources control, non-point sources control, and their combinations. The in-reservoir measures were supposed to treat sediment at Chuso basin and to install a phosphorus elimination plant (PEP) at the end of So-oak stream. The results showed that the effect of each measure was influenced by the hydrological condition of the year. In wet year, as the contribution of non-point sources increased, the non-point source control measures (NPS1~NPS4) showed more effective compared to other measures, while, the PEP system to eliminate phosphorus from So-oak stream showed better performance in dry year. In particular, the scenario of NPS1, in which all livestock manures were collected and treated but only chemical fertilizers (NPS1) were used for agriculture fields, showed the best performance for the control of algal bloom in Chuso basin among the watershed measures.

Prioritizing subwatersheds for non-point source pollution management in Saemangeum watershed using AHP technique (AHP 기법을 이용한 새만금유역의 비점오염원 우선관리지구 선정)

  • Woo, Hye-Jin;Jang, Taeil;Choi, Jin-Kyu;Son, Jae-Kwon
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.3
    • /
    • pp.101-112
    • /
    • 2015
  • The objective of this study was to investigate non-point sources (NPS) pollution and prioritize management areas affected by NPS pollution in the Saemangeum Watershed. AHP (Analytical Hierarchy Process) technique was selected to prioritize sub-watersheds for effectively managing NPS pollution in this study areas. Generation properties of NPS pollution, discharge properties of NPS pollution, and runoff properties of NPS pollution were selected and set for AHP. Weighted descriptors including indicators like numbers of livestock, land- and livestock-system loads, rainfall, and impervious area ratio were generalized from 0 to 1 and multiply each index based on screened 17 survey data. The results were visualized as maps which enable resource managers to identify sub-watersheds for effective improving water quality. The sub-watersheds located in Gongdeok-Myeon, Yongji-Myeon, Hwangsan-Myeon of Gimje-Si were selected for managing NPS pollution control areas. This result presented that these sub-watershed are more affected by the pollution from livestock-system than from land-system. The finding from this study can be used to screen sub-watersheds that need further assessment by managers and decision-makers within the study area.

Decision of Critical Area Due to NPS Pollutant Loadings from Kyongan Stream Watershed using BASINS-SWAT (BASINS-SWAT 모델을 이용한 경안천 유역의 비점원 오염배출 중점관리 대상지역 결정)

  • Jang, Jae-Ho;Yoon, Chung-Gyeong;Jung, Kwang-Wook;Son, Yeung-Kwon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.69-78
    • /
    • 2009
  • In order to improve water quality of upper watershed of Paldang reservoir, it is necessary to evaluate non-point source pollution loads and identify critical watershed pollution sources. A GIS based Soil and Water Assessment Tool was applied to evaluate model application and reliability, estimate NPS pollution load, identify critical watershed by NPS pollution sources, and suggest various best management practices for Kyongan Stream watershed. Yearly NPS pollution loads were estimated 30.0% SS, 60.1% TN and 35.4% TP, respectably. The watershed pollution load is mainly decided by precipitation condition and SS and nutrients load have a significant regression relationship. Based on 10-year average yearly NPS pollution load, critical sub-watersheds were identified. The No. 5 and 17 which have lots of relatively intensive agricultural fields and scattered industrial area were vary critical sub-watersheds and under more intensive pollution load. In order to control critical watershed, watershed best management practices such as scientific fertilizer, contour farming and parallel terrace, transferring the sloppy farmland to grass or forest and constructing a buffer zone, and constructing wetlands and retention ponds will be applied. Overall the SWAT model can be efficiently used for identification of critical sub-watersheds in order to develop a priority watershed management plan to reduce water pollutions.

Quantitative Assessment of Nonpoint Source Load in Nakdong River Basin

  • Kwon, Heon-Gak;Lee, Jae-Woon;Yi, Youn-Jeong;Cheon, Se-Uk
    • Journal of Environmental Science International
    • /
    • v.23 no.1
    • /
    • pp.7-23
    • /
    • 2014
  • This study estimates unit for the nonpoint source(NPS), classified according to the existing Level-1(large scale) land cover map, by monitoring the measurement results from each Level-2(medium scale) land cover map, and verifies the applicability by comparison with previously calculated units using the Level-1 land cover map. The NPS pollutant loading for a basin is evaluated by applying the NPS pollutant unit to Dongcheon basin using the Level-2 land cover map. In addition, the BASINS/HSPF(Better Assessment Science Integrating point & Non-point Sources/Hydrological Simulation Program-Fortran) model is used to evaluate the reliability of the NPS pollutant loading computation by comparing the loading during precipitation in the Dongcheon basin. The NPS pollutant unit for the Level-2 land cover map is computed based on precipitation measured by the Sangju observatory in the Nakdong River basin. Finally, the feasibility of the NPS pollutant loading computation using a BASINS/HSPF model is evaluated by comparing and analyzing the NPS pollutant loading when estimated unit using the Level-2 land cover map and simulated using the BASINS/HSPF models.

Analysis of Water-quality Improvement Efficiency of Constructed Wetland Using NPS-WET Model (NPS-WET 모형을 이용한 인공습지의 수질정화효과 분석)

  • Rhee, Han-Pil;Jung, Kwang-Wook;Lee, Bok-Soo;Ham, Jong-Hwa;Son, Yeong-Kwon
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.320-331
    • /
    • 2012
  • A combination system of catch canal and constructed wetland was designed and suggested to improve water quality in gagricultural region of lower Dong-jin river basin. In order to evaluate an water quality improvement efficiency of the designed combination system, the NPS-WET model was applied in this study. Simulation result of the NPS-WET shown that the nutrient load removal rate of constructed wetland was BOD, T-N, T-P and SS was 30.7~39.0%, 46~60%, 40.7~57.0% and 68.2~74.7%, respectively. Nutrients reduction of constructed wetland was higher in growing season than winter season because vital activity of microorganism, macrophyte and algae was augmented with high air and water temperature. Effluents from constructed wetland can affect water-quality of catch canal drains, especially, water-quality on junction point to Dong-jin river. Water-quality improvement in low-flowed catch canal (Un-san) was more significant than in high-flowed catch canal (Won-pyeong). In conclusion, a feasible design of constructed wetland is necessary to treat large quantity of receiving water. The NPS-WET is useful tool for assessing water-quality improvement efficiency using constructed wetland.

Verification of Nonpoint Sources Runoff Estimation Model Equations for the Orchard Area (과수재배지 비점오염부하량 추정회귀식 비교 검증)

  • Kwon, Heon-Gak;Lee, Jae-Woon;Yi, Youn-Jeong;Cheon, Se-Uk
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.1
    • /
    • pp.8-15
    • /
    • 2014
  • In this study, regression equation was analyzed to estimate non-point source (NPS) pollutant loads in orchard area. Many factors affecting the runoff of NPS pollutant as precipitation, storm duration time, antecedent dry weather period, total runoff density, average storm intensity and average runoff intensity were used as independent variables, NPS pollutant was used as a dependent variable to estimate multiple regression equation. Based on the real measurement data from 2008 to 2012, we performed correlation analysis among the environmental variables related to the rainfall NPS pollutant runoff. Significance test was confirmed that T-P ($R^2=0.89$) and BOD ($R^2=0.79$) showed the highest similarity with the estimated regression equations according to the NPS pollutant followed by SS and T-N with good similarity ($R^2$ >0.5). In the case of regression equation to estimate the NPS pollutant loads, regression equations of multiplied independent variables by exponential function and the logarithmic function model represented optimum with the experimented value.

Characteristics of Non-point Pollution Runoff in Mandae, Gaa, and Jaun Districts and Evaluation of Reduction Projects (만대·가아·자운지구 비점오염 유출특성 분석 및 저감사업 평가)

  • Woo, Soo-Min;Kum, Dong-Hyuk;Hong, Eun-Mi;Lim, Kyoung-Jae;Shin, Min-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.1
    • /
    • pp.65-77
    • /
    • 2022
  • Due to muddy water from the highland fields upstream of Soyangho Lake, the Mandae, Gaa, and Jawoon have been redesignated as NPS management areas. This study aims to evaluate the adequacy and supplementation points of the implementation plan by analyzing the operation status of muddy water generation and reduction facilities through on-site investigations by NPS management area to achieve the effective nonpoint pollution reduction goal in the implementation of the implementation plan established in 2020. The SS load calculated based on the survey results from July to October 2019 from 2017 showed a decreasen in 2019 compared to 2017. Both and the Jawoon were analyzed to have decreased. However, the amount of precipitation also decreased by about 27%, so it was judged that the effect of the reduction project was not significant. As a result of the detailed investigation of abatement facilities, about 86% of the 793 facilities installed in the management area were evaluated as 'good'. As a result of a detailed investigation by subwatersheds, subwatersheds 105 and 106 in the Mandae were analyzed as apprehensive subwatersheds. appeared to fall. In addition, it was analyzed that the effect of reducing muddy water in the Mandae district was insufficient due to the high ratio of leased farmers, lack of efforts to reduce turbid water in leased farmland, conversion to annual crops, and neglect of bare land. In the case of Gaa district, although the abatement facilities are concentrated in the upstream, muddy water was also found to be severe.

Analysis of Factors Affecting Retention Time in Grassed Swale (식생수로에서 유하시간에 영향을 주는 인자 분석)

  • Paek, Seoungbong;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.3
    • /
    • pp.303-310
    • /
    • 2015
  • Recently the water quality management policy gives priority to management the point source. Point pollution sources have definite emission points and are discharged to one point through a pipe. But Nonpoint pollution source (NPS) has uncertain pathway, pollutant load and runoff characteristics unlike point pollution sources, making them difficult to manage. Thus, the Korea government plans to develop and equip facilities that help reduce NPS so as to manage them more easily. But removal efficiency of Best Management Practice (BMPs) is in influenced by rainfall, hydrologic condition like natural phenomenon, so factors of removal efficiency are difficult. Thus there is a need for multilateral research about many factors that affect removal efficiency for removal facility design of proper non-point pollution. In this research, mapping, vegetation coverage and retention time were investigated in the case of factors that affect removal efficiency in grassed swale, a nature-type non-point removal facility. Grassed swale obtained changed of coverage using Braun-Blanquet within swale and retention time was obtained from point that rainfall effluent enters into swale to the time that first outflow starts. Besides, correlation analysis was obtained using pearson correlation analysis method. As a result, it was shown that removal efficiency increases as retention time is longer in grassed swale and that retention time increases as vegetation coverage is higher.

Long-term changes of water quality with regard to main Pollutant Sourses in Agricultural Reservoirs (주오염원별 농업용저수지의 장기 수질특성변화)

  • Choi, Sun-Hwa;Kim, Ho-Il;Yoon, Kyung-Seup;Park, Jong-Min
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.425-428
    • /
    • 2002
  • This study has been carried out to analized of long term changes of water quality with regard to main pollutant sources in agricultural reservoirs on the basis of data during 1996-2001. The major source was domestic wastewater(DWW) and water pollution by non-point sources(NPS) is increasing as time goes. It was determined that Seasonly average values of DWW were pH $7.6{\sim}8.7$, COD $7.0{\sim}9.4$, T-N $0.74{\sim}2.07$, T-P $0.05{\sim}0.62$, Live-stock wastewater(LWW) were pH $7.5{\sim}8.9$, COD $5.5{\sim}9.8$, T-N $0.57{\sim}1.91$, T-P $0.04{\sim}0.13$, NPS were pH $7.1{\sim}8.3$, COD $3.1{\sim}5.2$, T-N $0.29{\sim}1.44$, T-P $0.02{\sim}0.07$. Fluctuation of DWW and LWW were very wide and variable long term patterns of them were similar. Trophic states by Carlson Index of DWW and LWW was classified as eutrophic to hypretrophic from chl-a, T-P concentration.

  • PDF

Development of Infiltration System for Stormwater Management from Paved Area (포장지역 강우유출수 관리를 위한 침투도랑 기술개발)

  • Lee, Jeong-Yong;Maniquiz, Marla C.;Lee, So-Young;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.12 no.3
    • /
    • pp.165-175
    • /
    • 2010
  • Recently, various development projects have occurred due to rapid industrialization and urbanization. Both industry and population grew rapidly which causes a corresponding rise in pollution. The accumulated pollutants are washed-off during rainy days, highly degrading the water quality of the receiving water body. This is because a lot of non point source (NPS) pollutants were accumulated on the surface during dry periods. This research focuses on the development of Eco-Bio Filter (EBF) system that treats NPS pollutants. It is constructed at Kongju National University campus. The EBF is a type of a structured infiltration system that falls under the category of Low Impact Development (LID) hydrologic design practices. The monitoring of rain events was performed. It includes the development of design, the lessons learned from the post-construction testing and the improvements in the renovation made. After a series of monitoring, the MOE will use the results to apply the design to other areas in the country.