• 제목/요약/키워드: Non-Contacting Sensor

검색결과 22건 처리시간 0.021초

마이크로미터 변위 측정을 위한 비접촉식 전기용량 센서 개발 (Development of a Non-contacting Capacitive Sensor for Measurement of ${\mu}{\textrm}{m}$-order Displacements)

  • 김한준;이래덕;강전홍;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.768-771
    • /
    • 2001
  • Non-contacting capacitive sensor, based on principle of the cross capacitor, for measuring of $\mu\textrm{m}$-order displacements have been fabricated and characterized. To overcome disadvantages of the existed capacitive sensors of parallel type with 2-electrodes and 3-electrodes, the developed new sensor was designed to have 4-electrodes, two of them used high and low electrode the other two used as guard electrodes, on a sapphire plate with diameter 17 mm and thickness 0.7 mm, and are symmetrically situated with a constant gap of 0.2 mm between the electrodes. This sensor can be used for measuring the distance between sensor and target not only the metallic but also non-metallic target without ground connection.

  • PDF

섬유의 거칠기 측정에 있어서 비접촉식 방식과 접촉식 방식의 비교 (Comparison of contacting and non-contacting methods in measuring the surface roughness of texture)

  • 박연규;강대임;송후근;권영하
    • 감성과학
    • /
    • 제2권1호
    • /
    • pp.105-111
    • /
    • 1999
  • In order to introduce the touch to engineering and industries, it must be preceded to dstablish a quantitative barometer of the feeling. for this purpose, we developed a tactile measuring system to measure physical properties of texture, such as surface roughness, friction coefficient and compliance. The tactile measuring system uses a LASER type displacement sensor, which is a non-contacting system, in measuring the surface roughness. By considering that human tactile system is a contacting mechanism, this non-contacting method needs to be modified. As a precedent research of that, we compared the contacting and non-contacting method in this paper. Surface roughness of ten cloths were measured by using the measuring system, then compared to the test results using the Kawabata evaluation system(KES), which uses a contacting method in measuring the surface roughness.

  • PDF

Thompson-Lampard 정리를 적용한 마이크로미터 변위 측정을 위한 비접촉식 전기용량 센서 개발 (Development of a Non-contacting Capacitive Sensor Based on Thompson-Lampard Theorem for Measurement of ${\mu}m-order$ Displacements)

  • 김한준;강전홍;한상옥
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권9호
    • /
    • pp.443-448
    • /
    • 2006
  • Non-contacting capacitive sensor based on Thompson-Lampard theorem have been fabricated and characterized for measuring of 때 order displacements. To overcome disadvantages of the existed capacitive sensors of parallel plate type with 2-electrodes and 3-electrodes, the developed new sensor was designed to have 4-electrodes with a constant gap of 0.2mm between the electrodes. Two of the electrodes were used as a high potential electrode and a low one, the other two electrodes were used as guard electrodes. These electrodes were made from copper using RF sputtering system on a sapphire plate with diameter 17 mm and thickness 0.7 mm. This sensor can be used for measuring the distance not only between the sensor and metallic target connected to ground potential but also non-metallic target without ground connection.

비접촉식 4-전극형 전기용량 센서를 이용한 in situ 정밀측정 (Precise in situ Measurement using Non-Contacting Capacitive Sensor with 4-Electrodes)

  • 이래덕
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.93-98
    • /
    • 1999
  • Non-contacting capacitive sensors, based on principle of the cross capacitor, for measuring small displacement less than 1.95$\pm$0.5 mm have been fabricated and characterized. To overcome disadvantages of the existed capacitive sensors, the new sensor is consisted of 4-electrodes which are formed 2 active electrodes and 2 guard electrodes on a sapphire plate with diameter 17mm and thickness 0.7 mm, and are symmetrically situated with constant gap of 0.2 mm among the electrodes. The sensor is evaluated to be correlation coefficient of 0.9987 for the range of 1.95$\pm$0.5 mm and that of 0.9995 for 1.95$\pm$0.25 mm range. This sensor can be used for in situ measurements in the mechanical mirror polishing with precision less than $\pm$1${\mu}{\textrm}{m}$.

  • PDF

CAD 모델 기반 비접촉 기상 측정에 관한 연구 (Non-contacting OMM (On Machine Measurement) based on CAD Model)

  • 권세진;이정근;박정환;고태조;김선호
    • 한국정밀공학회지
    • /
    • 제20권11호
    • /
    • pp.134-141
    • /
    • 2003
  • An industrial product is designed and fabricated, followed by the inspection process in order to check whether it is dimensionally tolerable or not. The machining process produces a part such as a mold or die, in which the three-dimensional coordinate might be measured by a CMM (Coordinate Measuring Machine) for assessment of its dimension. It is not ignorable, however, that a CMM measurement requires a lot of operating time and cost, which has led to many studies on the OMM system. The OMM system can be categorized into contact and non-contact types, and each of which has its own strengths and weaknesses. Non-contacting types generally utilize structured lights, sounds or magnetic fields. Though they show rather poor performance in positional accuracy, the measuring speed is faster than the contacting probes. This paper presents the development of an OMM system based on a non-contacting laser displacement sensing apparatus and CAD model. The system is composed of software modules of center-aligning and measuring, which has been operated and verified on a NC machining center on a shop floor.

비접촉식 4-전극형 전기용량 센서를 이용한 in situ 정밀측정 (Precision in situ Measurement using Non-Contacting Capacitive Sensor with 4-Electrodes)

  • 김재열;이래덕;박기형;마상동;양동조
    • 한국정밀공학회지
    • /
    • 제19권3호
    • /
    • pp.33-38
    • /
    • 2002
  • To establish the national standard of capacitance, four main electrodes of the cross capacitor which were evaluated to linearity and roundness less the $\pm 1 \mu m$ respectively have to be adjusted symmetrically in an inner cylinder. Four LM shafts with diameter of 5 mm were installed between main electrodes of the cross capacitor, and the electrodes were adjusted, as the first step, by means of the measured capacitance. In the second step, the symmetrical adjustment up to $\pm 1.2\mu m$ was performed by using a ball sensor, ball-type movable sensor, non-contacting capacitive sensor and upper guard sensor which were developed in this project.

치과용 고주파 주조기를 위한 비접촉 단일 온도센서 설계 (Design of a non-contacting single infrared sensor for high frequency dental casting machine)

  • 황인;원용관;이상훈;송성근
    • 한국정보통신학회논문지
    • /
    • 제20권8호
    • /
    • pp.1546-1552
    • /
    • 2016
  • 일반적으로 치과용 주조기는 불때를 이용하여 합금을 용해하기 때문에 합금의 적절한 용융온도 및 주조시간을 조절하기 어렵고 이로 인해 가스공이나 핀홀과 같은 주조결함을 발생시키며 과열로 인한 보철물의 결함을 보이고 있다. 또한 합금이 용융된 후 주조 시 대부분 투시창이나 비접촉식 온도센서를 부착하여 적절한 주조온도가 되면 작업자가 원심력을 발생하는 버튼을 눌러 도가니에 용융된 합금을 주조링에 주입한다. 이러한 결과로 대부분 주조온도가 너무 높거나 낮아서 주조결함을 많이 발생하고 있으며 균일한 주조체를 얻지 못하고 있는 실정이다. 본 논문에서는 외부의 비접촉식 온도 센서를 이용한 온도계측이 아닌 실제 합금의 사용 온도를 계측할 수 있는 단일 온도센서를 이용한 치과용 고주파 주조기를 개발하였다.

역공학에서 측정경로생성을 위한 특징형상 인식 (Feature Recognition for Digitizing Path Generation in Reverse Engineering)

  • 김승현;김재현;박정환;고태조
    • 한국정밀공학회지
    • /
    • 제21권12호
    • /
    • pp.100-108
    • /
    • 2004
  • In reverse engineering, data acquisition methodology can generally be categorized into contacting and non-contacting types. Recently, researches on hybrid or sensor fusion of the two types have been increasing. In addition, efficient construction of a geometric model from the measurement data is required, where considerable amount of user interaction to classify and localize regions of interest is inevitable. Our research focuses on the classification of each bounded region into a pre-defined feature shape fer a hybrid measuring scheme, where the overall procedures are described as fellows. Firstly, the physical model is digitized by a non-contacting laser scanner which rapidly provides cloud-of-points data. Secondly, the overall digitized data are approximated to a z-map model. Each bounding curve of a region of interest (featured area) can be 1.aced out based on our previous research. Then each confined area is systematically classified into one of the pre-defined feature types such as floor, wall, strip or volume, followed by a more accurate measuring step via a contacting probe. Assigned to each feature is a specific digitizing path topology which may reflect its own geometric character. The research can play an important role in minimizing user interaction at the stage of digitizing path planning.

미소변위 측정용 비접촉식 4-전극형 전기용량 센서 (Non-Contacting Capacitive Sensor with 4-Electrodes for Measuring Small Displacement)

  • 이래덕;김한준;박세일;세묘노프
    • 센서학회지
    • /
    • 제7권2호
    • /
    • pp.90-96
    • /
    • 1998
  • Cross capacitor 원리를 이용하여 $1.95{\pm}0.5\;mm$ 이하의 미소변위를 비접촉으로 정확하게 측정할 수 있는 새로운 전기용량 센서를 설계 제작하였다. 전극의 구조는 센서와 측정 대상체가 각각 하나의 전극으로 작용하여야 하는 기존의 2-전극형 및 3-전극형 센서들이 지니고 있는 단점을 보완하기 위하여 2개의 전극(high, low전극)을 센서의 면에 형성한 4-전극형 센서로 제작하였다. 센서의 전극은 직경 17 mm 두께 0.7 mm인 사파이어 평행원판위에 구리를 사용하여 전극간 간격유지를 0.2 mm로 일정하게 함과 동시에 완전대칭을 이루도록 제작하였다. 따라서 이 센서는 측정대상체가 금속, 비금속에 관계없이 센서와 측정대상체와의 미소변위 및 간격을 측정 할 수가 있다. 측정범위 $1.95{\pm}0.5\;mm$에서의 correlation coefficient는 0.9987, $1.95{\pm}0.25\;mm$에서는 0.9995로 측정되었다.

  • PDF

비 접촉식 차량용 Transmitter Switch에 관한 연구 (A study on Non-contacted Transmitter Switch for Vehicle)

  • 안종영;김영섭;김성수;허강인
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권5호
    • /
    • pp.245-249
    • /
    • 2010
  • 현재 차량에서 일반적으로 많이 쓰이고 있는 변속 스위치의 방법은 전위차를 신호로하는 접촉식이다. 접촉식은 신호전달에 있어서 정확한 방식의 하나이지만 장시간 사용 시 접촉면의 노후화로 인하여 수명이 짧아진다. 비 접촉 방식으로 사용될 수 있는 자기센서를 사용 한다면 접촉면의 노후화를 해결 할 수 있다. 본 논문에서는 자기센서의 특징을 살려서 비 접촉식 방법으로 차량용 변속스위치에 적용 하여 기존 접촉식 방법의 문제를 해결하였다. 센서 출력 전압은 가변적인 전위차를 가지는데 스위치의 각동에 따라 통상 0mV에서 150mV의 값을 가진다. 본 연구에서는 5개의 상태 신호에 대한 두 개의 사인 신호를 사용 하였다.