• Title/Summary/Keyword: Non-Contact Test

Search Result 354, Processing Time 0.03 seconds

Control of Non-Contact Bearing-Based Motor-Generator System (비접촉 베어링 지지 모터-발전기 시스템의 제어)

  • Kim, Jong-Moon;Kang, Do-Hyun;Park, Min-Kook
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.861-863
    • /
    • 2003
  • In this paper, a controller for a non-contact bearing-based motor-generator system is designed. The levitation control method is a digital PID control. The plant dynamics consisting of actuator and rigid rotor dynamics are described. And some experiments are conducted with each global control and local control concept. From the whirl test, the Motor-Generator System can be controlled within about ${\pm}10{\mu}m$ gap variation at the rotational speed of 600rpm and generate electric power of AC100V.

  • PDF

Human Skin Safety Test of Green Tea Cell Extracts in Condition of Allergic Contact Dermatitis

  • Kim, Hyun-Kyu;Choi, Sun-Young;Chang, Hui-Kyoung;Baek, Seok-Yun;Chung, Jin-Oh;Rha, Chan-Su;Kim, Beom-Joon;Kim, Myeung-Nam
    • Toxicological Research
    • /
    • v.28 no.2
    • /
    • pp.113-116
    • /
    • 2012
  • Various kinds of positive effects of green tea extracts had been studied for long time which included anti-inflammation, anti-aging, and cardiometabolic effects. Although topical steroid and non-steroidal calcineurin inhibitors may control clinical symptoms of allergic contact dermatitis, some of patients also present allergic reaction to these topical agents. Therefore, we have tried green tea extracts for managing this skin disorder with expectation of anti-inflammatory effect without potential side effects including skin irritation and toxic responses. The toxicity test of green tea extract also did not show any sign of irritation in the skin throughout the test period. Moderate severity of allergic contact dermatitis presented satisfactory clinical outcome at second week follow-up which was final visit of outpatient. This result mean that green tea extract has a positive effect for managing allergic contact dermatitis but its potency and efficacy seem to be so not strong enough to control moderate severity allergy skin lesion. In this pilot study, we were able to conclude that green tea cell extracts might be applied for potential anti-inflammatory soaking without skin toxicity.

Occlusal and Periodontal Status of Teeth with Non-carious Cervical lesions (비우식성 치경부병소를 가진 구치부 치아의 교합 및 치주상태에 관한 연구)

  • Son, Min-Ook;Seo, Sung-Chan;Jeong, Dong-Keun;Lee, Eun-Suk;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.647-657
    • /
    • 2004
  • A non-carious cervical lesion(NCCL) is the loss of tooth structure at the cementoenamel junction level that is unrelated to dental caries. This study was to evaluate the occlusal and periodontal status of teeth with non-carious cervical lesions. We evaluated 105 teeth with non-carious cervical lesions in 35 subjects aged 38-75 years and characterized them based on the shape and dimension, plaque retention, bleeding on probing(BOP), probing pocket depth(PPD), occlusal status, brushing type, hypersensitivity and wear facet. The results of this study were as follows 1. No significant association was observed between cervical lesions and occlusal contact in lateral excursions. 2. No significant difference occurred in plaque retention, PPD, BOP between teeth with and without cervical lesions. 3. Test teeth had a significantly higher percentage of hypersensitivity and occlusal wear facet than teeth without cervical lesions. 4. Wedge shaped lesions had a significantly higher percentage of plaque than saucer shaped lesions. 5. Teeth with plaque were found to have significantly deeper PPD than teeth without plaque retention in cervical regions. 6. Teeth with occlusal contacts were found to have significantly deeper PPD than teeth without occlusal contacts. 7. No significant association was observed between cervical lesions and PPD independent of plaque retention and occlusal contacts Although more knowledge is necessary, our results suggest that occlusal contact and bacterial plaque may influence on periodontal tissue, but NCCL is not directly associated with periodontal health

Non-linear analysis of composite steel-concrete beams with incomplete interaction

  • Cas, Bojan;Bratina, Sebastjan;Saje, Miran;Planinc, Igor
    • Steel and Composite Structures
    • /
    • v.4 no.6
    • /
    • pp.489-507
    • /
    • 2004
  • The flexibility of the connection between steel and concrete largely influences the global behaviour of the composite beam. Therefore the way the connection is modelled is the key issue in its structural analysis. Here we present a new strain-based finite element formulation in which we consider non-linear material and contact models. The computational efficiency and accuracy of the formulation is proved with the comparison of our numerical results with the experimental results of Abdel Aziz (1986) obtained in a full-scale laboratory test. The shear connectors are assumed to follow a non-linear load-slip relationship proposed by Ollgaard et al. (1971). We introduce the notion of the generalized slip, which offers a better physical interpretation of the behaviour of the contact and gives an additional material slip parameter. An excellent agreement of experimental and numerical results is obtained, using only a few finite elements. This demonstrates that the present numerical approach is appropriate for the evaluation of behaviour of planar composite beams and perfect for practical calculations.

New method of optical laser extensometer

  • Noh, jiwhan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.79.2-79
    • /
    • 2002
  • 1. the principal of a PSD(Position Sensitive Detector) 2. the optical system of the proposed method 3. signal processing 4. experimental result A mechanical engineer experiment on the tension test. In this experiment, they use the extensometer which can measure the extended distance of material. A normal extensometer is the contact type which means that the extensometer should attached to the specimen. It is not convenient to the user. The contacting type can also effect the characteristic of the specimen. So a extensometer is changed from contacting type to non-contacting type. Non-contacting type is not necessary to attach the extensometer to the specimen...

  • PDF

The Influence of Weathering Conditions on the Outer Membrane of Biogas with Plasticized PVC : A Study using Non-destructive Tests

  • Kim, Changhwan;Ki, Wootae;Kim, SangMyung;Shin, Jinyong
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.2
    • /
    • pp.57-62
    • /
    • 2014
  • The biogas holder is composed of an outer membrane and an inner membrane which are subject to outdoor exposure and gas exposure respectively. The influence of weathering conditions on the photo-degradation of a biogas holder was investigated. Tests were performed under three different methods - outdoor exposure tests (Seosan, Arizona), accelerated tests (Xenon-are lamp) with the outer-membrane of biogas. Moreover, the changes in the aging process were monitored using color difference, gloss, the contact angle and an optical microscope. Changes in physical properties, such as decrease reduction in gloss, decrease in the contact angle, increase in color difference were observed in the aging process. The comparison between membrane 3B, 4B and membrane 5B under xenon-arc were discussed. Membrane 5B was very sensitive to ultraviolet (UV) ray. There were many difficulties in the outdoor exposure test due to acid rain, dust, and stain resistance.

Numerical and experimental study on flexural behavior of reinforced concrete beams: Digital image correlation approach

  • Krishna, B. Murali;Reddy, V. Guru Prathap;Tadepalli, T.;Kumar, P. Rathish;Lahir, Yerra
    • Computers and Concrete
    • /
    • v.24 no.6
    • /
    • pp.561-570
    • /
    • 2019
  • Understanding the realistic behavior of concrete up to failure under different loading conditions within the framework of damage mechanics and plasticity would lead to an enhanced design of concrete structures. In the present investigation, QR (Quick Response) code based random speckle pattern is used as a non-contact sensor, which is an innovative approach in the field of digital image correlation (DIC). A four-point bending test was performed on RC beams of size 1800 mm × 150 mm × 200 mm. Image processing was done using an open source Ncorr algorithm for the results obtained using random speckle pattern and QR code based random speckle pattern. Load-deflection curves of RC beams were plotted for the results obtained using both contact and non-contact (DIC) sensors, and further, Moment (M)-Curvature (κ) relationship of RC beams was developed. The loading curves obtained were used as input data for material model parameters in finite element analysis. In finite element method (FEM) based software, concrete damage plasticity (CDP) constitutive model is used to predict the realistic nonlinear quasi-static flexural behavior of RC beams for monotonic loading condition. The results obtained using QR code based DIC are observed to be on par with conventional results and FEM results.

Sectional analysis of stamping processes using Equilibrium approach (평형해법에 의한 스탬핑 공정의 단면 해석)

  • Yoon, J.W.;Yoo, D.J.;Song, I.S.;Yang, D.Y.;Lee, J.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.4
    • /
    • pp.58-68
    • /
    • 1994
  • An equilibrium approach is suggested as an effective tool for the analysis of sheet metal forming processes on the basis of force balance together with geometric relations and plasticity theroy. In computing a force balance equation, it is required to define a geometric curve approximating the shape of the sheet metal at any step of deformation from the geometric interaction between the die and the deforming sheet. Then the geometic informations for contacting and non-contacting sections of the sheet metal such as the number and length of both non-contact region, contact angle, and die radius of contact section are known from the geometric forming curve and utilized for optimization by force balance equation. In computation, the sheet material is assumed to be of normal amisotropy and rigid-phastic workhardening. It has been shown that there are good agreements between the equilibrium approach and FEM computation for the benchmark test example and auto-body panels whose sections can be assumed in plane-strain state. The proposed equilibrium approach can thus be used as a robust computational method in estimating the forming defects and forming severity rather quickly in the die design stage.

  • PDF

Finite Element Simulation of Axisymmetric Tube Hydroforming Processes (축대칭 튜브 하이드로포밍 공정의 유한요소 시뮬레이션)

  • Kim Y. S.;Keum Y. T.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.58-61
    • /
    • 2001
  • An implicit finite element formulation for axisymmetric tube hydroforming is investigated. In order to describe normal anisotropy of the tube, Hill's non-quadratic yield function is employed. The frictional contact between die and tube and frictionless contact between tube and fluid are considered using the mesh-normal vector computed from finite element mesh of the tube. In order to verify the validity of the developed finite element formulation, the axisymmetric tube bulge test is simulated and simulation results are compared with experimental measurements. In the axisymmetric tube hydroforming process, an optimal hydraulic curve is pursued by performing the simulation with various internal pressures and axial forces.

  • PDF

Determination of Elastic Modulus by Time Average ESPI and Euler-Bernoulli Equation (Time Average ESPI와 Euler-Bernoulli 방정식에 의한 탄성계수 측정)

  • Kim, Koung-Suk;Lee, Hang-Seo;Kang, Young-June;Kang, Ki-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.7 s.196
    • /
    • pp.69-74
    • /
    • 2007
  • The paper proposes a new sonic resonance test for a elastic modulus measurement which is based on time-average electronic speckle pattern interferometry(TA-ESPI) and Euler-Bernoulli equation. Previous measurement technique of elastic constant has the limitation of application for thin film or polymer material because contact to specimen affects the result. TA-ESPI has been developed as a non-contact optical measurement technique which can visualize resonance vibration mode shapes with whole-field. The maximum vibration amplitude at each vibration mode shape is a clue to find the resonance frequencies. The dynamic elastic constant of test material can be easily estimated from Euler-Bernoulli equation using the measured resonance frequencies. The proposed technique is able to give high accurate elastic modulus of materials through a simple experiment set up and analysis.