• Title/Summary/Keyword: Non-Conducting

Search Result 470, Processing Time 0.03 seconds

On Feasibility Study of the Charged Particle Beam Pretreatment Process for Non-conducting Metal Coating (무전도 금속 증착을 위한 하전 입자빔 전처리 공정의 타당성 연구)

  • Na, Myung Hwan;Park, Young Sik;Shim, Ha-Mong;Chun, Young Ho
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.2
    • /
    • pp.179-187
    • /
    • 2014
  • Purpose: Since several problems were found when present non-conducting metal coating process was applied to mass production, we study and develop to improve those problems. Methods: In this paper, a couple of analysis methods such as surface hardness, XPS spectrum analysis, morphology, and reflection ratio were used. Results: This paper suggest a new possibility of Non-conducting thin metal coating method that has quality of mass production phase without UV coating process. Conclusion: By the result of analysis, we can set optimized process conditions of the electro deposition coating using electron beam.

A Study on Comparing between Nursing Teachers and Non-Nursing Teachers of Conducting Sex Education and Teachers' Perceptions of Teaching Ability (보건교사와 일반교사의 성교육 수업실태와 교수능력 인식 비교)

  • Bae, Jung-Il
    • Journal of the Korean Society of School Health
    • /
    • v.16 no.1
    • /
    • pp.67-80
    • /
    • 2003
  • The purpose of this study was to find out differences between nursing teachers and non-nursing teachers in sex education, to offer the degree of conducting sex education and teachers' perceptions of teaching ability The subjects were 291 middle and high school teachers in Busan from June 25 to July 22, 2002. The results of this study are as follows. 1. According to the survey of 22 items relating to the degree of conducting sex education, the average of nursing teachers(2.87) was higher than that of non-nursing teachers(2.69). This finding showed that there was a significant difference between both groups(p<.05). 2. According to the survey of 22 items relating to teaching abilities, the average of nursing teachers(2.88) was higher than that of non-nursing teachers(2.63). There was also a significant difference between both groups(p<.01). According to the results of the study, I make the following suggestions. 1. Sex education should be adopted as a regular course and conducted as a school health program in regular curriculum. 2. Compared with non-nursing teachers, nursing teachers conducted sex education frequently and efficiently and their perception of sex education was higher. Therefore, the school policy which requires that sex education should be conducted by nursing teachers only is to be established.

Reliability Enhancement of Anisotropic Conductive Adhesives Flip Chip on Organic Substrates by Non-Conducting Filler Additions

  • Paik, Kyung-Wook;Yim, Myung-Jin
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2000.04a
    • /
    • pp.9-15
    • /
    • 2000
  • Flip chip assembly on organic substrates using ACAs have received much attentions due to many advantages such as easier processing, good electrical performance, lower cost, and low temperature processing compatible with organic substrates. ACAs are generally composed of epoxy polymer resin and small amount of conductive fillers (less than 10 wt. %). As a result, ACAs have almost the same CTE values as an epoxy material itself which are higher than conventional underfill materials which contains lots of fillers. Therefore, it is necessary to lower the CTE value of ACAs to obtain more reliable flip chip assembly on organic substrates using ACAs. To modify the ACA composite materials with some amount of conductive fillers, non-conductive fillers were incorporated into ACAs. In this paper, we investigated the effect of fillers on the thermo-mechanical properties of modified ACA composite materials and the reliability of flip chip assembly on organic substrates using modified ACA composite materials. For the characterization of modified ACAs composites with different content of non-conducting fillers, dynamic scanning calorimeter (DSC), and thermo-gravimetric analyzer (TGA), dynamic mechanical analyzer (DMA), and thermo-mechanical analyzer (TMA) were utilized. As the non-conducting filler content increased, CTE values decreased and storage modulus at room temperature increased. In addition, the increase in tile content of filler brought about the increase of Tg$^{DSC}$ and Tg$^{TMA}$. However, the TGA behaviors stayed almost the same. Contact resistance changes were measured during reliability tests such as thermal cycling, high humidity and temperature, and high temperature at dry condition. It was observed that reliability results were significant affected by CTEs of ACA materials especially at the thermal cycling test. Results showed that flip chip assembly using modified ACA composites with lower CTEs and higher modulus by loading non-conducting fillers exhibited better contact resistance behavior than conventional ACAs without non-conducting fillers.ers.

  • PDF

Reliability Enhancement of Anisotropic Conductive Adhesives Flip Chip on Organic Substrates by Non-Conducting Filler Additions

  • Paik, Kyung-Wook;Yim, Myung-Jin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.1
    • /
    • pp.41-49
    • /
    • 2000
  • Flip chip assembly on organic substrates using ACAs have received much attentions due to many advantages such as easier processing, good electrical performance, lower cost, and low temperature processing compatible with organic substrates. ACAs are generally composed of epoxy polymer resin and small amount of conductive fillers (less than 10 wt.%). As a result, ACAs have almost the same CTE values as an epoxy material itself which are higher than conventional underfill materials which contains lots of fillers. Therefore, it is necessary to lower the CTE value of ACAs to obtain more reliable flip chip assembly on organic substrates using ACAs. To modify the ACA composite materials with some amount of conductive fillers, non-conductive fillers were incorporated into ACAs. In this paper, we investigated the effect of fillers on the thermo-mechanical properties of modified ACA composite materials and the reliability of flip chip assembly on organic substrates using modified ACA composite materials. For the characterization of modified ACAs composites with different content of non-conducting fillers, dynamic scanning calorimeter (DSC), and thermo-gravimetric analyser (TGA), dynamic mechanical analyzer (DMA), and thermo-mechanical analyzer (TMA) were utilized. As the non-conducting filler content increased, CTE values decreased and storage modulus at room temperature increased. In addition, the increase in the content of filler brought about the increase of $Tg^{DSC}$ and $Tg^{TMA}$. However, the TGA behaviors stayed almost the same. Contact resistance changes were measured during reliability tests such as thermal cycling, high humidity and temperature, and high temperature at dry condition. It was observed that reliability results were significantly affected by CTEs of ACA materials especially at the thermal cycling test. Results showed that flip chip assembly using modified ACA composites with lower CTEs and higher modulus by loading non-conducting fillers exhibited better contact resistance behavior than conventional ACAs without non-conducting fillers.

  • PDF

Effect of Non-Conducting Filler Additions on Anisotropic Conductive Adhesives(ACAs) Properties and the Reliability of ACAs Flip Chip on Organic Substrates (이방성 전도 접착제 물성과 유기 기판 플립 칩의 신뢰성에 미치는 비전도성 충진재의 영향)

  • Im, Myeong-Jin;Baek, Gyeong-Uk
    • Korean Journal of Materials Research
    • /
    • v.10 no.3
    • /
    • pp.184-190
    • /
    • 2000
  • We investigated the effect of filler content on the thermo-mechanical properties of modified ACA composite materials by incorporation of non-conducting fillers and the reliability of flip chip assembly on organic substrates using modified ACA composite materials. For the characterization of modified ACA s composites with different content of non-conducting fillers, differential scanning calorimeter (DSC), and thermo-gravimetric analyzer (TGA), dynamic mechanical analyzer (DMA), and thermo-mechnical analyzer (TMA) were utilized. As the non-conducting filler content increased, CTE values decreased and storage modulus at room temperature increased. In addition, the increase in the content of filler brought about the increase of Tg^{DSC}$ and $Tg^{TMA}$. However, the TGA behaviors stayed almost the same. Contact resistance changes were measured during reliability tests such as thermal cycling, high humidity and temperature, and high temperature at dry condition. It was observed that reliability results were significantly affected by CTEs of ACA materials especially at the thermal cycling test. Results showed that flip chip assembly using modified ACA composites with lower CTEs and higher modulus by loading non-conducting fillers exhibited better contact resistance behavior than conventional ACAs without non-conducting fillers.

  • PDF

A Topological Derivative Based Non-Iterative Electromagnetic Imaging of Perfectly Conducting Cracks

  • Ma, Yong-Ki;Park, Won-Kwang
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.1
    • /
    • pp.128-134
    • /
    • 2012
  • In this manuscript, we consider electromagnetic imaging of perfectly conducting cracks completely hidden in a homogeneous material via boundary measurements. For this purpose, we carefully derive a topological derivative formula based on the asymptotic expansion formula for the existence of a perfectly conducting inclusion with a small radius. With this, we introduce a topological derivative based imaging algorithm and discuss its properties. Various numerical examples with noisy data show the effectiveness and limitations of the imaging algorithm.

Selective leaching of valuable metals (Au, Ag etc.) from waste printed circuit boards (PCB)

  • Oh, Chi-Jung;Lee, Sung-Oh;Song, Jin-Kon;Kook, Nam-Pyo;Kim, Myong-Jun
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.193-197
    • /
    • 2001
  • This study was carried out to recover gold, silver and other valuable metals from the printed circuit boards (PCB) of waste computers. PCB samples were crushed to under 1mm by a shredder and initially separated into 30% conducting and 70% non-conducting materials by an electrostatic separator. The conducting materials, which contained the valuable metals, were then used as the feed material for magnetic separation where it was found that 42% was magnetic and 58% non- magnetic. The non-magnetic materials contained 0.227mg/g Au and 0.697mg/g Ag. Further leaching of the non-magnetic component using 2.0M sulfuric acid and 0.2M hydrogen peroxide at 85$^{\circ}C$ extracted more than 95% copper, iron, zinc, nickel and aluminium. Au and Ag were not extracted in this solution, however, more than 95% of Au and 100% of Ag were selectively leached with a mixed solvent (0.2M ammonium thiosulfate, 0.02M copper sulfate, 0.4M ammonium hydroxide). Finally, the residues were reacted with a NaCl solution to leach out Pb while sulfuric acid was used to leach out Sn. Recoveries reached 95% and 98% in solution, respectively.

  • PDF

Structural Properties of Polyaniline Blended with PNIPAM

  • Neupane, Kosh-Prasad;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.209-213
    • /
    • 2003
  • Polyaniline (PANi) composite particles were synthesized by chemical oxidation polymerization of aniline in presence of poly-n-isopropyl acryl amide (PNIPAM). The PANi particles formed in the reaction medium deposited onto non-conducting PNIPAM template to produce PANi-coated composite particles. The formation of composite was confirmed by FT-IR spectroscopy, and UV-VIS spectroscopy, and their morphological structures were examined by scanning electron microscopy (SEM). From the experimental results, it was determined that PANi was successfully coated onto non-conducting PNIPAM.

  • PDF

Structural Properties of polyaniline blended with PNIPAM

  • Neupane, Kosh-Prasad;Ha, Jin-Wook
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.334-336
    • /
    • 2003
  • Polyaniline(PANi) composite panicles were synthesized by chemical oxidation polymerization of aniline in presence of Poly-N-Isopropyl acryl amide(PNIPAM). The PANi panicles are formed in the reaction medium deposited onto non-conducting PNIPAM template to produce PANi-coated composite panicles. The formation of composite was confirmed by FT-IR spectroscopy, and UV-VIS spectroscopy, and their morphological structures were examined by scanning electron microscopy(SEM). From the experimental results, it was determined that PANi was successfully coated onto non-conducting PANIPAM.

  • PDF

SOLUTION OF THE BOUNDARY LAYER EQUATION FOR A MAGNETOHYDRODYNAMIC FLOW OF A PERFECTLY CONDUCTING FLUID

  • ZAKARIA, M.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.6 no.2
    • /
    • pp.63-73
    • /
    • 2002
  • The influence of unsteady boundary layer magnetohydrodynamic flow with thermal relaxation of perfectly conducting fluid, past a semi-infinite plate, is considered. The governing non linear partial differential equations are solved using the method of successive approximations. This method is used to obtain the solution for the unsteady boundary layer magnetohydrodynamic flow in the special form when the free stream velocity exponentially depends on time. The effects of Alfven velocity $\alpha$ on the velocity is discussed, and illustrated graphically for the problem.

  • PDF