• Title/Summary/Keyword: Non contact

Search Result 2,378, Processing Time 0.028 seconds

Evaluations on Performances of a Non-Contact Torque Measurement Technique for Rotatory Machinery (회전기계용 비접촉식 토크 측정법 성능 평가)

  • KIM, YEONGHWAN;KIM, YEONGHO;CHO, GYEONGRAE;KIM, UEIKAN;DOH, DEOGHEE
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.6
    • /
    • pp.642-647
    • /
    • 2018
  • Gas compressors are mostly driven by motors. It is important to measure the power of motors to evaluate their power efficiency, because the mechanical loads of gas compressors are always varied. In order to measure the power given to the driving motors, the torque should be measured. Manufacturers of compressors usually use the torque data to calculate the compressors qualities such as power consumption, efficiencies and failures. In general, measurements for the shaft torque of the compressors have been based upon contact types, strain gauges. In the cases of larger compressors, the contact type of strain gauges have several disadvantages such as large size and high cost. In this study, a relatively inexpensive and simple torque sensing technique that is not restricted to shaft diameter is introduced using visualization technique. Particle image velocimetry (PIV) has been adopted to complete non-contact torques measurements for rotating motors. In order to compare the performance of the newly constructed torque measurement technique, torque measurement by a transducer based on MEMS technology has been performed simultaneously during experiments.

Comparison of the Internal Fitness of Prostheses Fabricated with Non-Contact Extra-Oral Scanner and Intra-Oral Video Scanner (비접촉식 구강외 스캐너와 비디오방식 구강내 스캐너를 이용하여 제작된 보철물의 내면정확도 비교)

  • Park, Jin-Young;Kim, Ji-Hwan;Jeong, Il-Do;Lee, Gwang-Young;Kim, Won-Soo
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.263-269
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the internal fitness of prostheses fabricated with non-contact extra-oral scanner and those fabricated with intra-oral video scanner, with a comparative accuracy analyses of their precision and trueness. Methods: A polymethyl methacrylate (PMMA) model was fabricated by replicating a master model. The prostheses in the first group were fabricated based on the PMMA model with an intra-oral video scanner (IVS group). Following the fabrication of work models with Type IV Stone that were based on the PMMA model, the prostheses in the second group were fabricated with a non-contact extra-oral scanner (ENB group). The precision and trueness of the prostheses were calculated from comparisons of the three-dimensional images of the internal surfaces of the prostheses and those of the master model. Kruskal-Wallis tests were used to determine the statistical significance, with the level of type 1 error set at 0.05. Results: Trueness (P < 0.009) and precision (P < 0.001) did not differ significantly between the ENB and IVS groups. The IVS group exhibited lower trueness values and larger precision values than the ENB group. Conclusion: Although no significant differences were found in the internal fitness of the prostheses that were fabricated by the two different scanners, the intraoral video scanner-fabricated prostheses had better trueness, whereas the non-contact extra-oral scanner-fabricated prostheses had better precision.

Study on Non-contact Detection of Surface Cracks of the Metals Using an Open-Ended Coaxial Line Sensor at X-band (마이크로파 X-밴드에서의 종단 개방 동축선 센서를 이용한 금속표면균열의 비접촉 검출 연구)

  • Yang, Seung-Hwan;Kim, Dong-Seok;Kim, Ki-Bok;Kim, Jong-Heon;Kang, Jin-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.192-197
    • /
    • 2012
  • In this paper, a non-contact microwave technique was presented to detect the surface crack of the metals. An open-ended coaxial cable line was used as a sensor at 11 GHz, and the reflection coefficients were measured by scanning along the metal surface including artificial surface cracks. A parameter, the K value which was defined as the difference between maximum and minimum reflection coefficients, was measured and used to estimate the crack depth. A linear relationship between the K value and crack depth was found. This study showed that non-contact detection of the surface cracks of metals is possible using the open-ended coaxial line sensor at X-band.

Non-Contact Ultrasonic Testing of Aircraft Joints using Laser Generated Lamb Wave (레이저 여기 램파를 이용한 항공기 판재 접합부의 비접촉식 초음파 검사)

  • Jhang, Kyoung-Young;Kim, Hong-Joon;Ceringlia, Donatella;Djordjevic, Boro
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.163-168
    • /
    • 2001
  • Due to aging, adhesively bonded and riveted aircraft lap joints can contain distends, cracks around rivet holes, fatigue induced flaws, and corrosion. It is required for the safety of aircraft to inspect these defects through the whole region of mint in rapid speed. Bond quality or adhesively bonded and riveted aluminum lap splice joints is investigated using non-contact remote ultrasonic nondestructive evaluation (NDE). Non-contact ultrasonic tests are performed using laser generation and air-coupled transducer detection. A Q-switched Nd:YAG laser and a periodic transmission mask are used to generate a selected Lamb mode. The Lamb wave is generated on one side of the lap splice joint, propagates along the plate, interacts with the joint and is detected on the other side by a micromachined air-coupled capacitance transducer. Analysis of recorded signals allows to evaluate the condition of the bond.

  • PDF

Development of Non-contact Home Monitoring System for Infant Respiration to Prevent SIDS (영아 돌연사 방지를 위한 비접촉 방식의 가정용 영아 호흡 감시 시스템 개발)

  • Heo, Il-Kang;Myoung, Hyoun-Seok;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.2
    • /
    • pp.48-53
    • /
    • 2015
  • Sudden infant death syndrome(SIDS) continues to be general cause of infant death. Also, apnea is supposed to be one of the main risk factor of SIDS. Therefore, Infant's respiratory monitoring and real-time apnea detection is very important to prevent SIDS. In this study, we proposed a non-contact home monitoring system for infant's respiration using Doppler radar in order to prevent SIDS. The respiration data were acquired from a commercialized baby simulator(Simbaby$^{TM}$) using a Doppler radar. To evaluate a performance of the proposed system, the simulator was placed in a supine and prone position and the chest belt was used simultaneously as a reference signal. As a result, correlation coefficients between respiration rates of Doppler radar and the chest belt in each position were 0.95(p < 0.001) and 0.98(p < 0.001), respectively. The averages of difference were $-0.29{\pm}5.21(mean{\pm}1.96{\cdot}$ standard deviation) in supine and $-0.12{\pm}3.05$ in prone from Bland-Altman analysis. The results indicated an excellent performance in detecting apnea with a sensitivity of 100% and a positive predictive value of 100% in each posture respectively. These results demonstrated that a proposed Doppler radar system is suitable for non-contact respiratory monitoring in order to prevent SIDS of infant.

Air Jet Effect on Performance Improvement of Non-Contact Type Seals for Oil Mist Lubrication Systems (공기분사가 오일미스트 윤활 시스템용 비접촉 시일의 성능 향상에 미치는 영향)

  • Na, Byeong-Cheol;Jeon, Gyeong-Jin;Han, Dong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2159-2166
    • /
    • 2000
  • Recently, high performance machining center requires special type of sealing mechanism that prevent a leakage of oil jet or oil mist lubrication system. Sealing of oil-air mixture plays important r oles to have an enhanced lubrication for performance machining center. Current work emphasizes on investigations of the air jet effect on the protective collar type labyrinth seal. To improve sealing capabilities of conventional labyrinth seals, air jet is injected against the leakage flow. In this study, an adapted model is introduced to improve sealing capability of conventional non-contact type seals. It has a combined geometry of a protective collar type and an air jet type. Both of a numerical analysis by CFD (Computational Fluid Dynamics) and experimental measurements are carried out to verify sealing improvement. The sealing effects of the leakage clearance and the air jet magnitude aic studied in various parameters. Gas or liquid has been used as a working fluid for most of nori-contact types seals including the labyrinth seal. However, it is more reasonable to regard two-phase flows because oil mist or oil jet are used for high performance spindle's lubrication. In this study, working fluid is regarded as two phases that are mixed flow of oil and air phase. Both of turbulence and compressible flow model are also introduced in a CFD analysis to represent an isentropic process. Estimation of non-leaking property is determined by amount of pressure drop in the leakage path. Results of pressure drop in the experiment match reasonably to those of the simulation by introducing a flow coefficient. Effect of the sealing improvement is explained as decreasing of leakage clearance by air jetting. Thus, sealing effect is improved by amount of air jetting even though clearance becomes larger

Diameter Measurement of Cylindrical Objects by Non-Contact Method (비접촉식 방법에 의한 원통형 물체의 지름 측정)

  • Im, Bok-Ryoung;Kim, Sok-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.177-181
    • /
    • 2005
  • Although there are many ways to measure the diameter of a cylindrical object, in this study, the diameter of a cylindrical objects were measured by the geometric optical method and interference-diffraction method which are two kinds of tipical non-contact methods. In geometric optical method, the curved laser beam is formed on the cylindrical surface by spreading the inclined laser beam using the cylindrical lens. The curve is captured by CCD camera and the diameter is calculated by geometry. And the interference and diffraction patterns of investigated cylindrical objects are analyzed in interference-diffraction method. In this study, the cylindrical objects, whose diameters are $0.05\;mm\;\~\;100.50\;mm$ were measured by the geometric optical method and interference-diffraction method. The results show that in each method, the relative errors of the measurement are within $2\%$ and $1\%$, respectively and these non-contact methods can be applied in the quick measurement of many objects.

A Study on Making a Replica for Restoration of the Stone Lion Statue Excavated from Woljeong Bridge (월정교 출토 사자상 복원을 위한 모본 제작 연구)

  • Lee, Chan Young;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.31 no.2
    • /
    • pp.147-157
    • /
    • 2015
  • TExhibiting replicas of major artifacts is becoming common recently to raise their value and help the public to understand them. In Korea, more attention is paid only to appearance in creating replicas of artifacts. It is required to study reproduction technology minimizing damages to originals and applicable to massive artifacts like sculptures in the situation that replicas and artifact reproduction is increasing. To make a replica of the Stone Lion Statue excavated from Woljeong Bridge, a measured drawing and a cross section are produced based on art historical surveys using 3D scans. A non-contact reproduction method is selected. The strength of the non-contact reproduction method is that the output is detailed. Athough the non-contact method has known to be applicable only to small scale artifacts and require reprocess, it is discovered to be applicable to detailed statues like this lion statue. Therefore, this study may contribute to complement the historic authenticity of the statue as well as to raise its academic value. It also can be utilized as research material of similar artifacts'replicas and restoration.

Research on Emotional Convergence Technology based on Non Contact Sensing and Social Interaction. (비접촉 센싱 기술과 사회적 상호작용에 따른 감성융합기술 연구)

  • Hwang, Sung Teac;Whang, Mincheol
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.6
    • /
    • pp.163-170
    • /
    • 2017
  • In this paper want to recognize competition and cooperation as a non-contact sensing method among the social emotion that are caused by interaction. Experiments were conducted in a pattern matching task divided into competition and cooperation situations. Data collection was performed by extracting the micro-movement data of 15Hz component from the upper body image. We compared and analyzed the amount and the variation and synchronization. As a result, Amount and variation are bigger in competition than cooperation. Synchronization was higher in cooperation than competition. This can be seen as the difference between two people trying to win when they are in competition and trying to breathe each other in cooperation. This study is significant in confirming the possibility of competition and cooperation through non contact sensing method based on physiological response.

The Development of Temperature Measurement System using Non-Contact Temperature Sensor Array (비접촉식 온도센서 어레이를 활용한 온도 계측시스템 개발)

  • Kim, Sung-Dae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2087-2092
    • /
    • 2015
  • Recently, use of the heat transferring machine and systems has been increasing in various industrial fields. A key technique for constructing such process is basically to measuring temperature directly to objects established on industrial plants. Particularly, a non-contact temperature measurement is very important to realize advanced heat transferring systems. This paper presents a new measurement methodology for temperature by using USN(ubiquitous sensor networks) technique including the microprocessor unit based ZigBee communication systems. This proposed system is made to be applied in monitoring systems for non-contact temperature measurement. We designed firmware based measurement systems whose main function is to save s series of temperature data sets and send it to main monitoring systems.