• Title/Summary/Keyword: Non contact

Search Result 2,378, Processing Time 0.027 seconds

A Study on Influence of Digital Literacy on Intention of Non-contact Service Continuous Use -Focusing on satisfaction and self-efficacy as a mediator variable and age as a moderating variable- (디지털 리터러시가 비대면 서비스 지속사용에 미치는 영향 연구 -만족, 자기 효능감 매개변수와 연령 조절변수 중심으로-)

  • Na, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.20 no.5
    • /
    • pp.187-195
    • /
    • 2022
  • The demand for non-contact service has increased a lot along with the development of technology and the generalization of social distancing to prevent COVID-19 spread during the pandemic. This study analyzed mediator and moderating variables between digital literacy and intention of continuous use of non-contact service were identified. The result showed that digital literacy had a significant influence on intention of continuous use of non-contact service. In particular, self-efficacy and satisfaction played a moderating role in the relation between digital literacy and intention of continuous use of non-contact service. This study is intended to contribute to expanding the base of non-contact service by verifying whether satisfaction and self-efficacy played important mediator variables in the relation between digital literacy and intention of continuous use of non-contact service

Performance Evaluations of a Novel Prototype of High Frequency Non-Contact Power Transformer

  • Gamage, Laknath;Ishitobi, Manabu;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.12-17
    • /
    • 2004
  • In this paper, a practical implementation to reduce leakage flux of a high-frequency inverter based non-contact type power transformer composed of EE-shape ferrite cores is presented for key technology of the next generation medical use X-ray CT scanner system. Design consideration for the unique structure of the non-contact power transformer with 900mm in diameter is also introduced. The complete non-contact transformer is actually arranged by several blocks of the magnetic circuit assembled by using 10 small EE shape cores with 120mm in length. It is experimentally and analytically discussed from a reduced leakage flux viewpoint related to its inductively coupling coefficient. A practical method to lower the leakage flux is described based on effective Copper-Sheet- Treatment placed on EE shape ferrite cores of magnetic circuit.

A study on the non-contact measurement for the temperature of shadow mask of Cathode Ray Tube using InSb photo sensor (인듐안티모나이드 포토 센서를 이용한 CRT 섀도우 마스크의 비접촉 온도 측정에 관한 연구)

  • 강대진;박정우;송창섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.15-20
    • /
    • 1997
  • This paper presents the experimental study of the non-contact temperature measurement for the shadow mask of cathode ray tube using InSb sensor. At present, High resolution of CRT(Cathode Ray Tube) is needed broadly; therefore, the measurement of temperature distribution of shadow mask in CRT during operation is important to analyze the thermal deformation of shadow mask. Most of the studies could not measure the temperature distribution of shadow mask precisely. We studied the temperature dis- tribution of shadow mask using InSb photo sensor for 17" cathode ray tube (CRT). Experiments using ther- mocouple are performed to validate the results of non-contact measurement. The results agree well with those results of non-contact method using InSb sensor.nsor.

  • PDF

POWER TRANSMISSION CHARACTERISTICS OF FEASIBLE NON-CONTACT PICK-UP COIL COUPLED TO HIGH-FREQUENCY POWER SUPPLY SYSTEM

  • Kuroda, Mitsuyoshi;Tsuda, Masanori;Okuno, Atsushi;Gamage, Laknath;Mutsuo, Nakaoka
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.447-451
    • /
    • 1998
  • This paper conducts a study on a non-contact power delivering system using high-frequency inverter with the purpose of discussing the non-contact electric power transmission characteristics through circuit analysis, magnetic analysis and feasible experiments. In this power delivering scheme, various properties pertaining to the non-contact transformer of the power system such as the design, the core depth, core material, primary side frequency etc. are considered with a view of improving the non-contact power dilivery to the secondary.

  • PDF

Non-contact type AFM using frequency separation scheme (주파수응답 분리방법을 이용한 비접촉식 AFM)

  • 이성규;염우섭;박기환;송기봉;김준호;김은경;박강호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.375-378
    • /
    • 2002
  • In this paper, the frequency response separation scheme is proposed for high scanning speed and simple structure of non-contact type of AFM. A self-sensing cantilever is attached on the actuator for detect the atomic force between tip and the media surface. VCM or PZT are used for actuator. This paper presents the method to simplify the actuator structure and the performance of each actuator for non-contact type AFM. Based on the frequency response separation scheme, the only one actuator plays roles 1311owing low frequency surface and modulating self-sensing cantilever tip in contrast with convention non-contact type AFM. 10 ${\mu}{\textrm}{m}$ standard grid sample imaged to verify proposed scheme. This result shows the possibility simplifying the actuator structure and reducing cost of non-contact type AFM.

  • PDF

The Effects of AFM Microcantilever Characteristics on the Non-Contact Mode Measurements (AFM 마이크로캔틸레버 특성에 따른 비접촉모드의 영향 고찰)

  • Hong, S.H.;Lee, S.I.;Lee, J.M.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1391-1395
    • /
    • 2006
  • In non-contact mode atomic force microscopy, the response of a resonating tip is used to measure the nanoscale topography and other properties of a sample surface. However, the tip-surface interactions can affect the tip response and destabilize the non-contact mode control. Especially it is difficult to obtain a good scanned image of high adhesion surfaces such as polymers using conventional hard NCHR tip and non-contact mode control. In this study, experimental investigation is made on the non-contact mode imaging and we report the microcantilever having low stiffness (OMCL) is useful to measure the properties of samples such as elasticity. In addition, we proved that it was adequate to use low stiffness microcantilever to obtain a good scanned image in AFM for the soft and high adhesion sample.

  • PDF

A Study on the Magnetic Suspension Type Linear Actuator for a Non-contact Surface Actuator (비접촉 평면구동기를 위한 자기 서스펜션방식 직선구동기)

  • Lee, Sang-Heon;Jung, Kwang-Suk;Baek, Yoon-Su
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.735-740
    • /
    • 2001
  • With the development of micro-technology, the demand for micro actuator is increasing. But, it is difficult to achieve high resolution and long travel range simultaneously with the conventional actuators. So, the noncontact surface actuator was proposed. This actuator can realize high dynamic range and the planar motion without complex cross-axis linear slides. This paper describes a magnetically suspended linear actuator for developing a non-contact surface actuator. The operating principle and the structure of the proposed linear actuator are similar to switched reluctance motor, but the proposed linear actuator utilizes normal force and propulsion force simultaneously. With this characteristic, the system can be simpler than other non-contact surface actuator.

  • PDF

A Study of the Non-Contact Bill Counter using Optical Fiber Sensor (광섬유 센서를 이용한 지폐 계수 장치에 관한 연구)

  • Kang, Dae-Hwa;Shin, Woo-Cheol;Song, Doo-Sang;Jang, Tak-Soon;Hong, June-Hee
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.231-236
    • /
    • 2007
  • In this paper, we studied the possibility of non-contact bill counting method using optical fiber sensor instead of traditionally used friction counting method. To implement non-contact counting, we designed and made optical fiber sensor and related parts. optical fiber sensor is made of optical fiber of 1mm diameter, photo diode and laser diode. Based on the conclusion which derived from preliminary experiment, instrument part is designed to make unevenness on the surface of bill paper and to stay parallel with optical fiber section. By analyzing the signal of optical sensor, we made counting program. Experimental instrument is composed of sensor part, instrument part, signal handling part. We checked the possibility of non-contact counting method after implementing experiment by using optical fiber sensor and instrument part.

A Study on Non-Contact Vocal Instruction (비대면 가창 수업 방법 고찰)

  • Lim, Ji-Hyun;Min, Kyung-Won
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.1
    • /
    • pp.27-38
    • /
    • 2021
  • Non-Contact society has arrived due to social distinctions by COVID 19 pandemic. The arrival of the era of non-contact is having a profound impact on educational activities as well as on our social and economic lives. In response to the pandemic situation universities and all other educational institutions have implemented non-contact online classes. In particular arts physical educations and other practical classes are experiencing many difficulties due to the limited environment caused by social distancing from COVID 19 pandemic. Vocal classes are undergoing a transition mainly from 1:1 individual face-to-face lessons or group teaching methods to the non-contact era of online teaching or lesson methods. It is necessary to look at the direction of non-face-to-face practical classes in preparation for accelerated educational innovation. Edu-tech, which innovates technology in the wake of the age of non-contact after COVID 19 pandemic is expected to begin in earnest at school sites in Korea which have remained in the traditional way of education. The purpose of this study is to effectively non-contact vocal instructional methods by cogitating the current state of higher practical education and vocal classes in Korea. In addition, This study conducted two components of satisfied instructions such as 'Priorlearning of monitoring of recorded singing', and 'Immediate analyzing of various vocal contents and supplementary lessons of music theory' with a research on the peos and cons of non-face-to-face vocal class. Over a period of time, The effective non-contact of vocal instructional methods is in need to supplement non-face-to-face vocal class problems and further research and system construction with non-face-to-face vocal class's pros and cons to construct high-quality lecture contents is warranted.

Analysis of Electrical Contact Resistance Model in Multi-Contact of Tribological Elements (트라이볼로지 기소의 멀티접촉에서 전기접촉저항 모델해석에 관한 연구)

  • 김청균
    • Tribology and Lubricants
    • /
    • v.12 no.4
    • /
    • pp.52-59
    • /
    • 1996
  • The results of the electrical contact conductivity of multi-contact spots accounting the surface roughness and the non-conductive films of different origins such as air, water, cutting oil, and machining oil are presented. The array of metal spheres compressed between two flat plates has been used for simulation of the contact behavior of multiple contact of solids, under normal loading. Measurement of electrical contact resistance has been made using the equipment providing the adequate accuracy in the range of micro Ohms. The data on electrical contact resistance have been compared with theoretical predictions using the multiple contact model of constriction resistance. The effect of single spot number and array on conductivity of contact has been evaluated. The results of the experiments show that the contact resistance are closely related to the number of loading cycles, form of surface roughness, and presence of non-conductive films that reduce the size of the real electrical contact spots.