• Title/Summary/Keyword: Non contact

Search Result 2,378, Processing Time 0.031 seconds

Relationship between the Deposition of Tear Constituents and the Adherence of Candida albicans according to Soft Contact Lens Materials and Pigmentation (소프트콘택트렌즈 재질과 착색에 따른 눈물성분 침착과 칸디다균 흡착의 상관관계)

  • Park, So Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.215-225
    • /
    • 2016
  • Purpose: The aim of this study was to figure out how the characteristics of soft contact lens materials and pigmentation affect the adherence of C. albicans on soft contact lenses pre-deposited with tear constituents. Methods: The adherent number of C. albicans on clear soft contact lenses (hereinafter clear lenses) and circle soft contact lenses (hereinafter circle lenses) made of etafilcon A, hilaiflcon B and nelfilcon A, respectively, was measured before and after the deposition of artificial tear. Also, bacteria adherence on lenses were observed by a scanning electron microscope. Results: Adherence of C. albicans was significantly different according to lens materials. The amount of adsorption was not different between clear lenses and circle lenses made of etafilcon A however, the number of bacteria absorption was bigger in hilafilcon B and nelfilcon A lenses. More absorption of C. albicans was found in the non-pigmented central area compared the pigmented area, and non-pigmented peripheral area has more bacterial absorption than non-pigmented central area. The number of C. albicans decreased in the case that tear protein was pre-deposited. The maintenance of antibacterial activity against C. albicans was different according to lens materials thus, etafilcon A has the longest period of its maintenance. Conclusions: It was revealed that the number of C. albicans was different according to the characteristics of lens materials, pigmentation or non-pigmentation, the pigmented area of soft contact lenses. Thus, it is suggested that the management method should be different according to the adsorption characteristics of C. albicans.

Non-Contact Level on Air Levitation Table with Porous Chamber Array (다공성 패드를 갖는 챔버의 배열에 따른 공기 부상 테이블의 비접촉 부상 수준에 대한 연구)

  • Kim, Joon Hyun;Jeong, Young Suk;Lee, Tae Geol;Kim, Tae Hoon;Jung, Hyo Jae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.913-920
    • /
    • 2013
  • This paper presents an applicable basic design that can configure non-contact levitation table for conveying a large sheet of glass. The suggested air levitation table consists of a series of air chambers with porous pads and fans as the conveyor system. The air supply chambers are arrayed to supply an adequately strong upward airflow for supporting the glass. Levitation is controlled by the size and discharge velocity, of the chamber arrays, as well as the glass supporting height. After pre-evaluation of the glass rigidity and the filer functional performance, a one-way fluid structure interface (FSI) analysis is performed for predicting pressure and deflection working of the 8G glass in the transverse and longitudinal directions, respectively. After comparing calculated levels of flatness of the glass, it determines the chamber array for the linear non-contact conveying motion.

Design of the Air Pressure Pick-up Head for Non-Contact Wafer Gripper (비접촉식 웨이퍼 그리퍼용 공압 파지식 헤드 설계)

  • Kim, Joon-Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.401-407
    • /
    • 2012
  • The recent manufacturing process in the thin wafers and flat panel necessitate new approaches to reduce handling fragile and surface-sensitive damage of components. This paper presents a new pneumatic levitation for non-contact handling of parts and substrates. This levitation can achieve non-contact handling by blowing air into an air pressure pick-up head with radial passages to generate a negative pressure region. Negative pressure is caused by the radial air flow by nozzle throat and through holes connecting to the bottom region. The numerical analysis deals with the levitational motion with different design factors. The dynamic motion is examined in terms of force balance(dynamic equilibrium) occurring to the flow field between two objects. The stable equilibrium position and the safe separation distance are determined by analyzing the local pressure distribution in the fluid motion. They make considerable design factors consisting the air pressure pick-up head. As a result, in case that the safe separation distance is beyond 0.7mm, the proposed pick-up head can levitate stably at the equilibrium position. Furthermore, it can provide little effect of torque, and obtain more wide picking region according to the head size.

A study on the Mathematical Tension Model for a Non-contact Transfer of a Moving Web in R2R e-Printing Systems (롤투롤 시스템에서의 비 접촉 이송 시스템을 위한 수학적 장력 모델에 관한 연구)

  • Lee, Chang-Woo;Kim, Ho-Joon;Kang, Hyun-Kyoo;Shin, Kee-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.9
    • /
    • pp.894-898
    • /
    • 2009
  • In a post printing section of roll to roll printing systems, scratch problem is the major defects. The functional qualities such as conductivity, mobility could deteriorate because of the scratch defect. In general, the scratch of the printed pattern on the flexible substrate was induced from a contact between rolls and printed pattern in the post printing section. In this paper, for non-contacting transfer of a moving web, a mathematical tension model has been developed considering strain due to air floatation and the proposed mode has been validated by numerical simulation. Additionally, the correlation between floatation height and speed compensation to control the tension and register are investigated. On the basis of the proposed model, a guide line of speed control in R2R printing system is presented to guarantee the non-contact between rolls and R2R printed pattern on the flexible substrate.

A Perspective on Surgical Robotics and Its Future Directions for the Post-COVID-19 Era (포스트 코로나 시대 수술 로봇의 역할 및 발전 방향에 관한 전망)

  • Jang, Haneul;Song, Chaehee;Ryu, Seok Chang
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.2
    • /
    • pp.172-178
    • /
    • 2021
  • The COVID-19 pandemic has been reshaping the world by accelerating non-contact services and technologies in various domains. Hospitals as a healthcare system lie at the center of the dramatic change because of their fundamental roles: medical diagnosis and treatments. Leading experts in health, science, and technologies have predicted that robotics and artificial intelligence (AI) can drive such a hospital transformation. Accordingly, several government-led projects have been developed and started toward smarter hospitals, where robots and AI replace or support healthcare personnel, particularly in the diagnosis and non-surgical treatment procedures. This article inspects the remaining element of healthcare services, i.e., surgical treatment, focusing on evaluating whether or not currently available laparoscopic surgical robotic systems are sufficiently preparing for the era of post-COVID-19 when contactless is the new normal. Challenges and future directions towards an effective, fully non-contact surgery are identified and summarized, including remote surgery assistance, domain-expansion of robotic surgery, and seamless integration with smart operating rooms, followed by emphasis on robot tranining for surgical staff.

Realization of Non-contact Sheet Resistance Measurement System for LCD using Eddy Current Probe (와전류탐침을 이용한 LCD용 비접촉식 면적저항 측정기의 구현)

  • 강신혁;최재훈황호정
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.617-620
    • /
    • 1998
  • In this paper we realized non-contact sheet resistance measurement system using eddy current. Proposed system is designed to meet the requirements which is necessary when dealing with conducting thin films on large area LCD panel. With several metals we could get lift-off curves which has the same trend as in principal. Especially in the region of high conductivity this system has more discriminating ability than 4-point probe system.

  • PDF

Contactless feed-back control method through power stage transformer in non-contact battery charger (무접점 충전기의 전력단 변압기를 통한 무접점 피드백 제어방식)

  • 김창균
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.258-261
    • /
    • 2000
  • A non-contact battery charger which transfers energy using magnetic field has a difficulty with a feed-back control due to the interaction between the power and signal processing This paper proposes an effective method which uses auxiliary windings of transformer as signal path and copes with cross-talk using the MOSFET ringing phenomenon and ceramic filter. The power stage is half-bridge series resonant converter. Design procedure and experimental verification are presented.

  • PDF

Measurement Errors of Non-contact Type Vibration Sensors Used for Precision Measurement of Shaft Vibration (정밀 축진동 측정에 사용되는 비접촉식 진동센서의 측정오차)

  • 전오성;김동혁;최병천
    • Journal of KSNVE
    • /
    • v.1 no.2
    • /
    • pp.107-113
    • /
    • 1991
  • When non-contact type vibration probes are used for the precision measurement of shaft vibration, they can induce the measurement errors due to the shaft curvature since they have been calibrated for the flat plate. In this study the errors due to the shaft radius and the misalignment between the shaft and probe centerlines are analyzed, and an in-situ calibration tool, which can be conveniently used for calibration independent of the shaft curvature and material, is introduced.

  • PDF