• Title/Summary/Keyword: Non contact

Search Result 2,375, Processing Time 0.034 seconds

A Study on the Design of ZVS Multi-Resonant Forward Converter for Non-contact Charging (비접촉 충전을 위한 ZVS 다중공진 포워드 컨버터의 설계에 관한 연구)

  • 김영길;김진우;박진홍;이종규;이성백
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.70-76
    • /
    • 2000
  • In the charge system, a contact type-convenient-charging method is insufficient because of the contact failure around moist environment and troublesome question to put in and pull out. For the solution of this problem, an electromagnetically coupled non-contact charger for the rechargeable cell is proposed using ZVS multi-resonant forward converter with synchronous rectifier. In this paper coupling coefficient(k), leaking inductance, coupling inductance and resonant frequency are observed for the air gap. By using the observed value, this circuit is designed and implemented. This proposed circuit is simulated by the PSPICE and experimented. The stress of a main switch and the output power are measured.

  • PDF

Contact treatment algorithm of z-map model with vertical walls and its application to the deep drawing of a clover shaped cup (Z-map으로 표현된 수직 벽면을 가진 금형에서의 접촉처리법과 클로버형 컵 디프드로잉 공정의 해석에의 응용)

  • 서의권;박정환;심현보
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.5
    • /
    • pp.38-45
    • /
    • 1998
  • The Z-map model which is quite similar to the non-parametric patch is widely used to describe the shape of a surface because of its simplicity. Despite the inherent advantage of z-map model. it has drawbacks that there exists difficulty in expressing the vertical walls and its related contact treatment method. In the region of vertical walls, there is a convergence problem in searching the contact point. In this study a contact point finding scheme is presented, based on the z value of the z-map model on the sheet normal direction. To show the utility of this scheme a compared with the experimental results. The effects of the Z-map grid distances and the interpolations of the inside Z-map value are also discussed.

  • PDF

A Design of ZVS Multi-Resonant Forward Converter for Non-contact Charging (비접촉 충전을 위한 ZVS 다중공진 포워드 컨버터의 설계)

  • Kim, Young-Gil;Na, Hee-Su;Kim, Jin-Woo;Lee, Sung-Paik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1300-1302
    • /
    • 2000
  • In the charge system, a contact type-convenient-charging method is insufficient because of the contact failure around moist environment and troublesome question to put in and pull out. For the solution of this problem, an electromagnetically coupled non-contact charger for the rechargeable cell is proposed using ZVS multi-resonant forward converter. In this paper magnetizing inductance, leakage inductance and coupling coefficient, k are observed. By using the obserbed value, the proposed circuit is simulated by the PSPICE and implemented and the peak voltage of switch and output power are measured.

  • PDF

Design of Non-stick Micromanipulation for Handling of Micro particle (초소형 부품 조작을 위한 Non-stick 마이크로 매니퓰레이션 시스템의 설계)

  • Ihn, Y.S.;Kim, Y.C.;Choi, H.R.;Lee, S.M.;Koo, J.C.
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.3
    • /
    • pp.225-232
    • /
    • 2009
  • In the high precision robot systems, the most popular tasks may be handling of micro-scale objects on a surface such as a micromanipulation robot system. In handling of micro-scale objects, the stiction effect becomes a fundamental issue since the micro-contact mechanics dominates the micromanipulation robot system. In the paper, a theoretical non-stick condition derived from the micro-contact mechanics is carried out for the propose of micro-scale object manipulation. To verify the non-stick condition, a micro-manipulation robot system equipped with a high precision stage system and a microscope system is developed. Experimental results show that the proposed non-stick condition guarantees successful micro-scale object manipulation.

  • PDF

A new magnetic sensor for the non-contact measurement of bending vibrations of non-ferromagnetic pipes (비자성 배관의 비접촉 굽힘 진동 측정을 위한 자기 센서의 개발)

  • Han, Soon-Woo;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1154-1158
    • /
    • 2006
  • This investigation suggests a new non-contact type sensor that can measure flexural vibrations of a non-ferromagnetic pipe. The sensor works on the reversed Lorentz force mechanism; however, anti-symmetric bias magnetic field suggested in this work should be applied to measure bending vibration of a non-ferromagnetic pipe. The importance of the suggested magnetic field is verified by a series of experiments. The sensor is applied to the bending vibration measurement and modal testing of an aluminum pipe and shows satisfactory working performance compared to others.

  • PDF

Compensation of the Discontinuous Properties of the Guide System using Magnetic Levitation (자기 부상 안내 기구의 불연속 특성 보상 방법)

  • Lee, Sang Joon;Jung, Kwang Suk
    • Journal of Institute of Convergence Technology
    • /
    • v.3 no.2
    • /
    • pp.11-15
    • /
    • 2013
  • These days, the quality of goods is required to improve in the process of manufacturing the semiconductor through the short working hours and clean transportation. The non-contact transport device using magnetic levitation can be a solution in the manufacturing process. The non-contact transport device, using electromagnetic actuation, is the system that can actually transport them by only using attraction force from the electromagnetic source without authentic contact. Moreover, the system using electromagnetic force has a substantial number of benefits ranging from unrestricted design to unlimited expansion. Especially, the price is competitive. The non-contact transport device, using electromagnetic force, has another merits in controlling by giving the same amount of attraction force to ferromagnetic body. By controlling the currents given to coil, the operator is able to decide the direction of the transportation. In order to design the optimal system, we implemented five different things such as the presence of the links below the electromagnetic, the electromagnet changes due to coupling method, the change according to the thickness of the links below electromagnet, due to changes in between electromagnetic distance direction, and the size of the current. Through simulations and the optimum design, it seems to control easily and figure out the exact size of power. It might definitely be the non-contact transport that can sharply reduce tiny scratches and particles in the process of manufacturing the semiconductor.

  • PDF

Study on the Seam Tracking by Using Fiber Sensor and X-Y Robot (Fiber Sensor와 X-Y Robot을 이용한 용접선 추적에 관한 연구)

  • 배철오;박영산;이성근;김윤식;안병원
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.144-149
    • /
    • 2001
  • There are many types of seam tracking methods actually used in industrial spot. Lately, Non-contact sensor technics are mostly used because non-contact sensor has more advantage than contact sensor in many parts. This paper also concerned about fiber sensor a kind of non-contact sensor. X-Y robot and fiber sensor scan the seam tracking to be weld. After scanning, X-Y robot moves the first working point of being scanned and welding starts automatically. It makes an experiment on some types of Seam tracking like straight line tracking, leaned line tracking and curved line tracking to confirm how well the fibers sensor tracks the seam pass to be weld. And the seam pass that had been tracked was welded by inverter $CO_2$ voiding machine.

  • PDF

Study on the Seam Tracking by Using Fiber Sensor and X-Y Robot (Fiber Sensor와 X-Y Robot을 이용한 용접선 추적에 관한 연구)

  • 배철오;이성근;김윤식;안병원;박영산
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.558-561
    • /
    • 2000
  • There are many types of seam tracking methods actually used in industrial spot. Lately, Non-contact sensor technics are mostly used because non-contact sensor has more advantage than contact sensor in many parts. This paper also concerned about fiber sensor a kind of non-contact sensor. X-Y robot and fiber sensor scan the seam tracking to be weld. After scanning, X-Y robot moves the first working point of being scanned and welding starts automatically. It makes an experiment on some types of Seam tracking like straight line tracking, leaned line tracking and curved line tracking to confirm how well the fibers sensor tracks the seam pass to be weld. And the seam pass that had been tracked was welded by inverter CO2 welding machine.

  • PDF

Flat Panel Display Deflection Analysis Considering Lift Force in Non-Contact Flat Panel Display Conveyer System (비접촉 평판 디스플레이 이송장치에서 양력을 고려한 평판 디스플레이의 처짐 해석)

  • Hwang, Sung-Hyen;Choi, Hyeon-Chang;Lho, Te-Jung;Son, Te-Yong;Park, Bum-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.5
    • /
    • pp.451-457
    • /
    • 2008
  • Flat Panel Display(FPD) is widely used a video display terminals to consumer products of LCD and PDP. The contamination and damage were affected by using the previous contact conveyor's method. In this paper, it analyzes the FPD deflection to develop the non-contact FPD transfer process using lift force. Each conveyor's equipment is called a horizontal conveyor, vertical conveyor and robot pick-up equipment. As result of an analysis of FPD panel's deflection, a robot pick-up equipment has performed according to under the present conditions like panel's weight and loaded glass to move FPD panel from one place to other places properly. Results of the analysis showed 0.474 mm, 0.424 mm and 1.237 mm. Those values are lower than a predicted optimum values : 2 mm for both horizontal and vertical conveyers; 5 mm for robot pick-up equipment. Therefore, those results verify each equipment have safety and reliability.

Motion Control of Non-Contact Start/stop Hard Disk Drive Using Shape Memory Alloy Actuator (형상기억합금 작동기를 이용한 비접촉 시동 및 정지형 하드디스크 드라이브의 운동제어)

  • Im, Su-Cheol;Park, Jong-Seong;Choe, Seung-Bok;Park, Yeong-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.196-202
    • /
    • 2002
  • In this work, we propose a new type of HDD suspension featuring shape memory alloy (SMA) actuator in order to prevent the contact between the slider and disk. The principal design parameters are obtained from the modal analysis using finite element analysis, and then the dynamic model is established to formulate the control scheme for Non-Contact Start/stop mode drive. Subsequently, a robust H$\_$$\infty$/ control algorithm is designed by integrating experimentally-Obtained SMA actuator dynamics to the proposed HDD suspension system. The controller is empirically realized and control results for the load/unload profiles are presented in time domain. In addition, the contact signal between the slider and disk is measured by the electrical resistance method.