• Title/Summary/Keyword: Non Operation

Search Result 2,617, Processing Time 0.035 seconds

Intermediate and Long Term Results for Extracardiac Conduit Repair Between Right Ventricle and Pulmonary Artery in Congenital Cardiac Defect (선천성 심장기형의 우심실-폐동맥 인조혈관 연결 수술후 중장기 성적)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.571-578
    • /
    • 1995
  • Rastelli operation in which right ventricle[RV and pulmonary artery[PA is connected with an artificial graft is effective in increasing the pulmonary blood flow in certain types of congenital heart disease but, in many, it requires a reoperation because of the relative stenosis of graft that develops as the patients become old. The purpose of this study is to evaluate the various factors which many influence the long term outcome of such patients following a Rastelli operation. A total of 47 patients underwent a Rastelli operation during a 15 year period between November, 1978 and October 1993. The mean follow-up period is 76.1 51.3 months.1 Among the 47 patients, a valved conduit was used in 30[63.8% , and non-valved conduit in 17[36.2% patients. In the 8 patients[17.0% who died postoperatively, a valved conduit was used in 5 [16.6% and a non-valved conduit in 3[17.6% . There was no statistical difference in mortality between the 2 groups. There was a good linear correlation between the body surface area[X and the conduit size[Y [Y=3.86X + 14.6, R=0.55, P=0.01 .2 Ten patients underwent replacement of the conduit during the follow-up period. The type of conduit used and the frequency of subsequent replacement were as follows: Ionescu-Shiley, valved-33.3%, Carpentier-Edwards, valved-30.8%, Hancock, valved-80% and non-valved conduit-9.1%. The median period free of reoperation was 110 months for the valved and 79 months for the non-valved group, there being no statistical difference between the 2 groups. 3 The patients who did not require reoperation are all doing well [New York Heart Association Functional Classification: Class I . Pressure gradient between the RV and the PA was 20 mmHg in 10 randomly selected patients who did not require reoperation and 92 9 mmHg in 10 patients who did require reoperation.4 In the 10 patients who underwent a conduit replacement procedure.5 Among patients undergoing reoperation, 2 died from endocarditis.The remaining 8 patients are doing well without limitation in physical activity at a mean follow-up period of 32.7 33.9 months [range 2 to 89 months . 6 At 5, 7, and 10 years, the reoperation-free rates among all patients were 96%, 91% and 29% and the survival rates were 82%, 82% and 71%. In conclusion, Rastelli operation is an effective procedure in ameliorating symptoms in a select group of patients with congenital heart disease. Because of the inherent nature of relative graft stenosis and degeneration, a long-term follow-up is required under the proper selection of the graft material.

  • PDF

Novel Self-Reference Sense Amplifier for Spin-Transfer-Torque Magneto-Resistive Random Access Memory

  • Choi, Jun-Tae;Kil, Gyu-Hyun;Kim, Kyu-Beom;Song, Yun-Heub
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.1
    • /
    • pp.31-38
    • /
    • 2016
  • A novel self-reference sense amplifier with parallel reading during writing operation is proposed. Read access time is improved compared to conventional self-reference scheme with fast operation speed by reducing operation steps to 1 for read operation cycle using parallel reading scheme, while large sense margin competitive to conventional destructive scheme is obtained by using self-reference scheme. The simulation was performed using standard $0.18{\mu}m$ CMOS process. The proposed self-reference sense amplifier improved not only the operation speed of less than 20 ns which is comparable to non-destructive sense amplifier, but also sense margin over 150 mV which is larger than conventional sensing schemes. The proposed scheme is expected to be very helpful for engineers for developing MRAM technology.

A study on efficient gate system based RFID at the container terminal

  • Kim, Hyun;Kim, Yul-Seong
    • Journal of Navigation and Port Research
    • /
    • v.30 no.4
    • /
    • pp.277-283
    • /
    • 2006
  • It is a world trend to construct large terminal and develop automated container terminal to attract Super Post-Panamax and provide service which is based on differentiation. In fact, there is insufficient research for automatization of terminal gate since the automatization of current constructed container terminal is only focused on increasing productivity and unmanned system through the automatization of quay, yard, etc. In this paper, we have investigated advantage/disadvantage of existing gate operation systems and compared each gate operation system in the aspect of raising terminal image and the productivity. For the specific study, we have used data from actual terminal gate operation and RFID model business sponsored by MOMAF (Ministry of Maritime Affairs and Fisheries). As a result, this paper carried out an efficient gate operation system and it has been expected that it will be performed as groundwork of automated gate operation system which is for design of container terminal and improvement of gate operation system.

Study on the Management of Doam Dam Operation by the Analysis of Suspended Solids Behavior in the lake (호내 부유물질 거동 분석을 통한 도암댐 운영 방안에 관한 연구)

  • Yeom, Bo-Min;Lee, Hye Won;Moon, Hee-Il;Yun, Dong-Gu;Choi, Jung Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.6
    • /
    • pp.470-480
    • /
    • 2019
  • The Doam lake watershed was designated as a non-point pollution management area in 2007 to improve water quality based on watershed management implementation. There have been studies of non-point source reduction with respect to the watershed management impacting the pollutant transport of the reservoir. However, a little attention has been focused on the impact of water quality improvement by the management of the dam operation or the guidelines on the dam operation. In this study, the impact of in-lake management practices combined with watershed management is analyzed, and the appropriate guidelines on the operation of the dam are suggested. The integrated modeling system by coupling with the watershed model (HSPF) and reservoir water quality model (CE-QUAL-W2) was applied for analyzing the impact of water quality management practices. A scenario implemented with sedimentation basin and suspended matter barrier showed decrease in SS concentration up to 4.6%. The SS concentration increased in the scenarios adjusting withdrawal location from EL.673 m to the upper direction(EL.683 m and EL.688 m). The water quality was comparably high when the scenario implemented all in-lake practices with water intake at EL.673 m. However, there was improvement in water quality when the height of the water intake was moved to EL.688 m during the summer by preventing sediments inflow after the rainfall. Therefore, to manage water quality of the Doam lake, it is essential to control the water quality by modulating the height of water intake through consistent turbidity monitoring during rainfall.

Utilization of Body Computed Tomography Scanners in Non-Metropolitan Area (비수도권(非首都圈) 지역(地域)에서의 전신용(全身用) X선(線) CT의 이용(利用))

  • Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.29-45
    • /
    • 1985
  • Computed Tomography Scanner (CT) is highly expensive in operation as well as purchasing. That reason may cause not only to increase the burden of patients but also to waste the capital resources leading to financial difficulties. However the numbers of CT installed throughout the country is increasing, because of efficiency in medical care, patient's concern, competitions among the hospitals within the same area. In the non-Metropolitan area the scanners were expected to be less utilized and less profitable. Nine hospitals equipped with the CT were studied on the utilization of that equipment during the period from November 1984 to February 1985 in non-Metropolitan area and break-even point in one hospital was analyzed for estimating profitabilities. The results were as follows ; 1. Among those nine hospitals, four hospitals had less than 400 beds, which is one of the restrictive minimum standards on the installation of Whole-body Computed Tomography Scanner. 2. The operating time during the normal operation period was longer than those of any other studies, but the accumulated down time was also longer than those of any other studies. The average number of scanning per week for each CT was 45, while the estimated number of for the break-even point was 56.7 cases. 3. When the downtime was excluded in calculating the average operation would be much closer to the cases for the break-even point. Therefore the break-down of the equipment was to be a main cause of the low profitability. 4. The average scanning rate for head area was 33.6%, however three of the nine hospitals showed about 20%. 5. If scanning ratio for the body parts excepting head was increased, the number of scanning for the break-even point would be diminished. 6. The small size hospital especially located near the Metropolitan area showed largest loss in the CT operation. In purchasing the highly expensive equipments in hospitals, demand should be taken into account and planning is recommended.

  • PDF

A Study on Geometrical Glue Operation between Non-manifold Models (비다양체 모델간의 기하학적 접합 연산에 관한 연구)

  • Park, Sang-Ho
    • Journal of the Korea Computer Graphics Society
    • /
    • v.4 no.1
    • /
    • pp.11-19
    • /
    • 1998
  • Non-manifold topological operations such as Euler and Boolean operations provide a versatile environment for modeling domains. The implementation of these operations raises geometrical issues that need to be addressed to ensure the topological validity of the underlying model, and they uses the glue operation which provides a basic method to modify the topology of non-manifold models when vertices, edges and faces are contacting each other. Topological information such as adjacency relationships should be inferred when gluing non-manifold models. Two methods of reasoning can be employed to find the topological information : topological reasoning and geometrical reasoning. The topological method can infer the adjacency relationships by using stored topological information. On the other hand, the geometrical method can find topological ambiguities by considering the geometrical shape at the local area of gluing when the topological relations were not stored. This paper describes the geometrical reasoning method.

  • PDF

Source Information Estimation Using Enemy's Single-Ping and Underwater Geographic Information in Non-Cooperative Bistatic Sonar (비협동 양상태 소나에서 적함 송신기의 단일 능동 신호와 해저 지형 정보를 이용한 송신기 정보 추정)

  • Lee, Dong-Hwa;Nam, Jong-Geun;Jung, Tae-Jin;Lee, Kyun-Kyung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.196-203
    • /
    • 2010
  • The bistatic sonar operations using a spatially-separated source and receiver are classified into cooperative and non-cooperative operations. In the cooperative operation, an active signal of a friendly ship is used and the source information is known previously. In the non-cooperative operation, an active signal of the enemy is used and it is difficult to find out the source information. The source information consists of the range, speed, course and frequency of the source. It gives advantage to operating bistatic sonar. This paper suggests a method of estimating the source information with geographic information in the sea and the single-ping of the enemy. The source range is given using one geographic point. And the source speed, course and the frequency of the enemy's source signal are given using two geographic points. Finally, the validity of the scheme is confirmed through a simulation study.

Non-Dissipative Snubber for High Switching Frequency and High Power Density Step-Down Converters (고속 스위칭 및 고 전력밀도 강압형 컨버터를 위한 무손실 스너버)

  • Shin, Jung-Min;Park, Chul-Wan;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.345-352
    • /
    • 2017
  • In this paper, a non-dissipative snubber for reducing the switching losses in the step down converter is proposed. The conventional step down converter, e.g., buck converter, suffers from serious switching losses and consequentially heat generation because of its hard switching. Thus, it is unsuitable for high switching frequency operation. Reduction of the reactive components' size, such as an output inductor and capacitor, is difficult. The proposed snubber can slow down the increasing current slopes and switch voltage at turn-on and turn-off transients, thereby significantly reducing the switching loses. Additionally, the slowly increasing current during switch turn-on transition, can effectively solve the output rectifier diode reverse recovery problem. Therefore, the proposed non-dissipative snubber not only leads to the efficiency of converter operation at high switching frequency but also reduces the reactive components size in proportion to the switching frequency. To confirm the validity of the proposed circuit, theoretical analysis and experimental results from a 150 W, 1 MHz prototype are presented.

Development of Process Planning System for Cold Forging of Non-axisymmetric Parts (비축대칭 제품의 냉간단조 공정설계시스템의 개발)

  • 이봉규;권혁홍;조해용
    • Transactions of Materials Processing
    • /
    • v.11 no.5
    • /
    • pp.405-413
    • /
    • 2002
  • A process planning system for cold forging of non-axisymmetric parts of comparatively simple shape was developed in this study. Programs for the system have been written with Visual LISP in AutoCAD. Shape of the product must be drawn with the solid line and the hidden line, and with the plane and front view, as well. At the plane, the system recognizes the external shape of non-axisymmetric portions - the number of the sides of the regular polygons and the radii of circles inscribing and circumscribing the polygon. At the front view, the system cognizes the diameter of axisymmetric portions and the height of the primitive geometries such as polygon, cylinder, cone, concave, convex, etc. The system perceives that the list developed from the solid line must be formed by the operation of forward extrusion or upsetting, and that the list developed from the hidden line must be formed by the operation of backward extrusion. The system designs the intermediate geometries again by considering clearance between workpiece and die, and then finally the billet diameter, in reverse order from the finished product, on the basis of volume constancy and using the operations, the forming sequence, the number of operations and the intermediate geometries which were already designed. The design rules and knowledges for the system were extracted from the plasticity theories, handbook, relevant reference and empirical knowledge of field experts. Suitability of the process planning was analyzed using SuperForge of FVM simulation package. The results of analysis showed good formability.

Comparative Analysis of Voltage Unbalance Factor on the use of Linear and Non-linear loads in Three-phase Four-wire Low Voltage Distribution Line (3상 4선식 저압 배전선로에서 선형 및 비선형 부하의 사용시 전압 불평형률 비교 분석)

  • Kim, Jong-Gyeum;Kim, Ji-Myeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.587-592
    • /
    • 2017
  • In the three-phase four-wire low-voltage power distribution equipment, single-phase and three-phase load have been used mainly mixed. Also linear and nonlinear loads have been used together in the same conditions. In a three-phase four-wire distribution line, the current distribution of three-phase linear load is almost constant in each phase during driving or stopping, but the single-phase load is different from each other for each phase in accordance with the operation and stop. So that the voltage unbalance is caused by the current difference of each phase. In the three-phase four-wire distribution system, non-linear load is used with linear load. The presence of single-phase nonlinear loads can produce an increase in harmonic currents in three-phase and neutral line. It can also cause voltage unbalance. In the present study, we analyzed for the voltage unbalance fluctuations by the operation pattern of the single and three-phase linear and non-linear load in three-phase four-wire low voltage distribution system.