• 제목/요약/키워드: Non Destructive Test

검색결과 473건 처리시간 0.033초

전자부품의 새로운 절연평가기법 연구 (A Study on the New Evaluation Method on Insulation of Electronic Components)

  • 길경석;송재용;문승보;차명수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.503-504
    • /
    • 2006
  • This paper describes a low-level partial discharge(PD) testing that has been accepted as a non-destructive test method on insulation performance of electronic components. A comparative PD analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards is carried out on high frequency switching transformers. The analysis shows that insulation degradation of the transformers under test progresses during the WVT. To avoid insulation degradation of the specimen, PD test has to be carried out at as low voltage as possible. In this study, the PD test on the transformers is performed in ranges from 50% to 70% of the test voltage specified in the WVT by measuring apparent charges below 1 pC. From the experimental results, it is expects that the low-level PD test is applicable for electronic components as a replacement of the WVT.

  • PDF

異性材料 마찰용접부의 기계적 성질검사 (Testing of Mechanical Properties on Dissimilar Metal Friction Welds)

  • 나석주
    • 대한기계학회논문집
    • /
    • 제8권1호
    • /
    • pp.41-47
    • /
    • 1984
  • Increase of the requirements on quality of welded structures necessitates the improvement of known inspection methods and the introduction of progressive new techniques. Non-destructive methods are the most advanced, but there are considerable difficulties in using the methods of radiography with electromagnetic rays and ultrasonic testing in the inspection of dissimilar metal friction welds, because their physical and mechanical properties are changed very rapidly at the interface. The values of simple mechanical test for dissimilar metal friction welds have always been dubious, as the strength of the bond is often greater than that of the softer materials being jointed. Thus, in this paper some conventional mechanical testing methods are examined in an attempt to determine a technique for dissimilar metal friction welds, which will give a reliable quantitative indication of the weld quality. From the considered static and dynamic testing methods the impact bending test on unnotched and notched specimens are the most sensitive to find out the small joining defects in the interface.

초음파를 이용한 반도체의 신뢰성 평가 (Reliability Evaluation of Semiconductor using Ultrasonic)

  • 장효성;하욥;장경영;김정규
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2001년도 정기학술대회
    • /
    • pp.239-244
    • /
    • 2001
  • Today, Ultrasonic is used as an important non-destructive test tool of semiconductor reliability evaluation and failure analysis. The semiconductor packaging trend goes to develop thin package, this trend makes difficult to inspect to defect in semiconductor package. One of the important problem in all semiconductor is moisture absorption in the atmosphere. This moisture causes crack or delamination to package when the semiconductor package is soldered on PCB. Reliability evaluation of semiconductor's object is investigating the effect of this moisture. For that reason, this study is investigating the effect of this moisture and reliability evaluation of semiconductor after preconditioning test and scanning acoustic microscope.

  • PDF

NDE for Realising Better Quality of Life in the Context of INDIA - An Emerging Economy

  • Raj, Baldev
    • 비파괴검사학회지
    • /
    • 제23권5호
    • /
    • pp.497-519
    • /
    • 2003
  • Science and technology is an essential ingredient of the progress in modern society. Measurements enable action and actions enable results. Non-Destructive Evaluation (NDE) - the science and technology of measurements without affecting the Properties and performance of the test object is an interdisciplinary domain area of high significance far ensuring quality, productivity and safety thus enabling better qualify of lift to the inhabitants on this planet. The test object can be material, component, plant, earth, environment etc. Total qualify management, total productivity management, concurrent engineering and many other essential ingredients of success in plant engineering and manufacturing industry are dependent on NDE far success and good returns on investments.

저온 플라즈마 공정용 펄스발생 전원장치의 성능시험 (Test Results of Pulsed Power Supply for Nonthermal Plasma Process)

  • 장성덕;변영철;조무현;신동남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1574-1575
    • /
    • 2011
  • The application of a pulsed power system is being extended to an environmental and industrial field. The non-destructive gaseous pollutants from industrial plants such as power generation plants and incinerators can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The pulsed plasma generator with a triggered switch has been developed. Its corona current in load can be adjusted by applied voltage and repetition rate. We investigated the performance of the pulsed plasma generator by analyzing the concentration of ozone in small reactor. This paper describes the electrical characteristics of the pulse generator with a voltage of 30 kV at repetition rate of 50 PPS. In addition, we briefly discuss a configuration of the system and initial test results.

  • PDF

가변극성 플라즈마 아크용접을 이용한 알루미늄 합금의 키홀 용접 (Keyhole Welding of Aluminum Alloy by Variable Polarity Plasma Arc Welding)

  • 유준태;탁정수;윤종훈;장영순;이영무;강석봉
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2006년 추계학술발표대회 개요집
    • /
    • pp.72-74
    • /
    • 2006
  • The application of the variable polarity plasma arc welding process to A12219 is described. The thickness of aluminum alloy is 11.45mm and 5.08mm. 1-pass keyhole welding is applied to butt welding and 2-pass welding is also applied to thick material. During welding, all welding parameters are controlled by automated system and acquired by 10kHz rate. This paper covers the welding parameters, result of non-destructive test and tensile test.

  • PDF

비파괴 탐상에 의한 ACSR 전선의 결함 검출 (Corrosion Detection of ACSR Power Lines Using Non-Destructive Test Method)

  • 강지원;장태인;민병욱;김북규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1712-1714
    • /
    • 2001
  • This paper deals with the development and application of an inner corrosion detector for the ACSR(Aluminum Conductor Steel Reinforced) power lines. The detector runs on an ACSR power line and inspects the inner corrosion of the conductor using the technology of the nondestructive eddy current test. It is consists of an ECT sensor, signal processing units, a RF transmitter/receiver, and etc.. The experimental result through field tests shows the detector can efficiently find both the zinc and aluminum loss of ACSR power lines.

  • PDF

저압주조품의 미세조직과 기계적성질에 미치는 금형온도의 영향 (Effect of the Mold Temperatures on the Microstructure and Mechanical Properties of Low Pressure Die-Cast Product)

  • 이정근;박종성;김명호
    • 한국주조공학회지
    • /
    • 제18권3호
    • /
    • pp.254-261
    • /
    • 1998
  • Microstructure and mechanical properties of the low pressure die-cast Al wheels were investigated by microscope, image analyzer, NDT (non-destructive test), and tensile test. The variation of SDAS (secondary dendrite arm spacing), porosity per unit area, quality grade, and tensile properties with the mold temperatures were examined. SDAS was gradually decreased with a decrease in temperature. However, the lowest value of porosity per unit area was observed at the mold temperature of $405^{\circ}C$ and the optimum mold temperature was found to be $405^{\circ}C$. Besides, from the observation of pore morphology, it was also found that the pore formation was mainly caused by shrinkage during solidification. The tensile strength, elongation, and impact toughness were markedly decreased, however the yield strength was nearly constant. The decrease of mechanical properties is attributed to the increase of porosity.

  • PDF

후판 강용접부의 신뢰성 평가 (Evaluation of Reliability for Welded thick steel joint)

  • 최원두;이영호;길두송;박상기
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.327-329
    • /
    • 2004
  • Reliability evaluation of the welded structure for industrial structures/facilities such as power plant and petro-chemical refinery facilities is very important, and especially the reliability diagnosis of the structure is based on the exact evaluation of materials properties. But, the conventional Pre-Qualification test had the difficulty of evaluating the real material properties in the field because the test was made on the specimen with the simulated welding for the in-field welding condition. Therefore, a continuous indentation technique was proposed for simple and non-destructive testing of in-field structures and for selective testing of local range such as heat affected zone and weldment.

  • PDF

부분방전 측정에 의한 저압용 유도전동기의 절연성능 평가 (Evaluation on Insulation Performance of Low-voltage Induction Motors by Partial Discharge Measurement)

  • 박대원;최수연;최재성;길경석;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1887-1891
    • /
    • 2008
  • In this paper, we dealt with a partial discharge (PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage induction motors. The PD measurement system consists of a coupling network, a low noise amplifier, and associated electronics. A shielded box was used to reduce environmental noise. Frequency characteristic of the coupling network was estimated by a sinusoidal signal input, and the low cut-off frequency of the coupling network was 1 MHz (-3 dB). Also, we carried out a calibration test for the PD measurement system. Sensitivity of the system was of 84 m$V_{max}$/pC between stator winding and enclosure. In application test on a low-voltage three phase induction motor (5 HP), we could detect 88 pC at AC 800 $V_{max}$.

  • PDF