• Title/Summary/Keyword: Nominal Frequency

Search Result 166, Processing Time 0.029 seconds

Design of Capacitive Power Transfer Using a Class-E Resonant Inverter

  • Yusop, Yusmarnita;Saat, Shakir;Nguang, Sing Kiong;Husin, Huzaimah;Ghani, Zamre
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1678-1688
    • /
    • 2016
  • This paper presents a capacitive power transfer (CPT) system using a Class-E resonant inverter. A Class-E resonant inverter is chosen because of its ability to perform DC-to-AC inversion efficiently while significantly reducing switching losses. The proposed CPT system consists of an efficient Class-E resonant inverter and capacitive coupling formed by two flat rectangular transmitter and receiver plates. To understand CPT behavior, we study the effects of various coupling distances on output power performance. The proposed design is verified through lab experiments with a nominal operating frequency of 1 MHz and 0.25 mm coupling gap. An efficiency of 96.3% is achieved. A simple frequency tracking unit is also proposed to tune the operating frequency in response to changes in the coupling gap. With this resonant frequency tracking unit, the efficiency of the proposed CPT system can be maintained within 96.3%-91% for the coupling gap range of 0.25-2 mm.

A Study of Optimal Design of the Proportional Load-Frequency Controller for a Self-service Power Station (주파수제어를 위한 비열제어기구의 최적설계에 관한 연구)

  • 장세훈;임화영
    • 전기의세계
    • /
    • v.26 no.2
    • /
    • pp.99-103
    • /
    • 1977
  • The object of this work is to study an optimal design problem of the proportional load-frequency controller for the single-control area power system. The selfservice power station is still a popular means as a power supplying source on ships or in a certain manufacturing area. The power system of this kind can be formulated as a single control-area system and it attracts a certain academic interest in controlling the system frequency under disturbances. In this paper, the single control-area system is mathematically formulated as a linear, time-invariant system in state-space under certain assumptions. The optimal proportional control law and the realization of the controller in closed loop-version is studied so that the final system designed can attain the system frequency to the nominal stationing value after the small load-disturbance. As in general cases of optimal design problems, the performance index is assumed to be quadratic in states and the control effort, and the infinite time control process is assumed in this work. The final control system realized depicts certain improvements in case study; in stability, transient responses and in steady-state frequency deviation, even though the steady state error did not attain the zero value.

  • PDF

AN LMI APPROACH TO AUTOMATIC LOOP-SHAPING OF QFT CONTROLLERS

  • Bokharaie, Vaheed S.;Khaki-Sedigh, Ali
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.433-437
    • /
    • 2003
  • Quantitative Feedback Theory (QFT) is one of effective methods of robust controller design. In QFT design we can considers the phase information of the perturbed plant so it is less conservative than $H_{\infty}$ and ${\mu}$-synthesis methods and as be shown, it is more transparent than the sensitivity reduction methods mentioned . In this paper we want to overcome the major drawback of QFT method which is lack of an automatic method for loop-shaping step of the method so we focus on the following problem: Given a nominal plant and QFT bounds, synthesize a controller that achieves closed-loop stability and satisfies the QFT boundaries. The usual approach to this problem involves loop-shaping in the frequency domain by manipulating the poles and zeros of the nominal loop transfer function. This process now aided by recently developed computer aided design tools proceeds by trial and error and its success often depends heavily on the experience of the loop-shaper. Thus for the novice and First time QFT user, there is a genuine need for an automatic loop-shaping tool to generate a first-cut solution. Clearly such an automatic process must involve some sort of optimization, and while recent results on convex optimization have found fruitful applications in other areas of control theory we have tried to use LMI theory for automating the loop-shaping step of QFT design.

  • PDF

Validation of Job Analysis for Hospital HIV/AIDS Nurse Counselor (의료기관 에이즈 상담간호사 직무의 타당성)

  • Baek, Hee Chong;Cho, Hee;Han, Jong Sook
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.19 no.2
    • /
    • pp.173-182
    • /
    • 2012
  • The purpose of this study is to identify the appropriateness and validity of the HIV/AIDS nurse counselor's job, and to propose the job description. Mixed method was used: nominal group interview was used as a qualitative research and a survey was used as a quantitative research. Three of the nominal group members evaluated the appropriateness of the duties and tasks. To identify the validity of the evaluated duties and tasks, importance, difficulty and frequency were surveyed by 14 nurses who were working at the hospital as a HIV/AIDS nurse counselors. For the HIV/AIDS nurse counselor, 7 duties and 35 tasks - infection control of the HIV/AIDS, counseling, client advocacy, development of the educational material, referral to the resources, referral services at the hospital, and self-improvement - were identified. Proposed job description will be used as a reference for the role position and the training curriculum of the HIV/AIDS nurse counselors who are working at the hospital.

  • PDF

Design of DC Battery Size & Controller for Household Single-Phase ESS-PCS Considering Voltage Drop and DC Link Voltage Ripple (주택용 단상 ESS-PCS의 전압손실과 직류링크 맥동을 고려한 직류측 배터리 사이즈 및 제어기 설계)

  • Kim, Yong-Jung;Lee, Jinsung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.94-100
    • /
    • 2018
  • Generally, in a single-phase energy storage system (ESS) for households, AC ripple component with twice the fundamental frequency exists inevitably in the DC link voltage of single-phase PCS. In the grid-connected mode of a single-phase inverter, the AC ripple component in the DC link voltage causes low-order harmonics on grid-side current that deteriorates power quality on an AC grid. In this work, a control system adopting a feedforward controller is established to eliminate the AC ripple interference on the DC link side. Optimal battery nominal voltage design method is also proposed by considering the voltage loss and AC ripple voltage on DC link side in a single-phase ESS. Finally, the control system and battery nominal voltage design method are verified through simulations and experiments.

Charge-coupled analog-to-Digital Converter (전하결합소자를 이용한 Analog-to-Digital 변화기)

  • 경종민;김충기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.5
    • /
    • pp.1-9
    • /
    • 1981
  • Experimental results on a 4-bit charge-coupled A/D converter are described. Major operations in the successive approximation algorithm are implemented in a monolithic chip, CCADC, which was fabricated usir p-channel CCD technology, with its die size of 4,200 mil2 Typical operating frequency range has been found out to be from 500Hz to 200kHz. In that frequency range, no missing code has been found in the whole signal range of 2.4 volts for ramp signal slewing at 1 LSB/(sampling time). A discussion is made on several layout techniques to conserve the nominal binary ratio of (8:4:2:1) among the areas of four adjacent potential wells (M wells), whose charge storing capacities correspond to each bit magnitude - 3.6 pC, 1.8 pC, 0.9 pC, and 0.45 pC nominal in the order of MSB to the LSB. The effect of 'dump slot', which is responsible for the excessive nonlinearity (2$\frac{1}{2}$LSB) in the A/D converter, is explained. A novel input scheme called 'slot zero insertion' to circumvent the deleterious effects of the dump slot is described with the experimental results.

  • PDF

Contour Plot to Explore the Structure of Categorical Data

  • Kim, Hyun Chul;Huh, Moon Yul;Chung, Hee Suk
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.2
    • /
    • pp.371-385
    • /
    • 2003
  • In this paper, contour plot is considered as a method to explore the structure of categorical data. For this purpose, the paper suggests a method to sort two-way contingency table with respect to the expected marginals. It is found that the suggested plot provides us with valuable information for the underlying data structure. Firstly, we can investigate independency between the categories by examining the differences of expected frequency contours and observed frequency contours. With the plot, we can also visually investigate the existence of outliers inherent in the data. These properties of the suggested contour plot will be demonstrated by several sets of real data.

Muffler Design Using a Topology Optimization Method (위상 최적화 기법을 이용한 머플러 설계)

  • Lee, Jin-Woo;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1085-1089
    • /
    • 2007
  • An acoustic topology optimization method is developed to optimize the acoustic attenuation capability of a muffler. The transmission loss of the muffler is calculated by using the three-point method based on finite element analysis. Each element of the finite element model is assumed to have the variable acoustic properties, which are penalized by a carefully-selected interpolation function to yield clear expansion chamber shapes at the end of topology optimization. The objective of the acoustic topology optimization problem formulated in this work is to maximize the transmission loss at a target frequency. The transmission loss value at a deep frequency of a nominal muffler configuration can be dramatically increased by the proposed optimization method. Optimal muffler configurations are also obtained for other frequencies.

  • PDF

Enhanced Performance of Disturbance Observer by Embedding a Filter and Its Application to Hard Disk Drive (필터 삽입에 의한 외란 관측기의 성능 향상과 하드디스크 장치에의 적용)

  • Ha, Jongsoo;Park, Gyunghoon;Shim, Hyungbo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.9
    • /
    • pp.811-817
    • /
    • 2015
  • In this paper, we present a new control structure which is obtained by adding an appropriately designed filter to a conventional disturbance observer. The proposed controlled system preserves advantages of a system with the conventional disturbance observer; disturbance rejection and nominal performance recovery. In particular, by embedding the filter, the disturbance rejection performance is enhanced compared with that of the classical disturbance observer-based controlled system. Moreover, we suggest a condition for the robust internal stability of the considered system in this paper. Simulation results regarding an effect of relatively high-frequency disturbance on hard disk drive are also presented.

A Study on the Emergency Control Algorithm for Viability Crisis of Power System (계통사고시 장해경감을 위한 긴급제어 알고리즘에 관한 연구)

  • 송길영;이희영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.9
    • /
    • pp.591-599
    • /
    • 1988
  • After the short-term dynamics due to the major disturbance are over, the power system may lead to viability crisis state wherein there is possibility of cascading damage. This paper presents an emergency control algorithm to alleviate the obstacles of system frequency or bus voltage during the viability crisis state. The algorithm considers the effects of controlling reactive power sources for load shedding and generation reallocation in order to alleviate the obstacles. The problem is decomposed into a subproblem I and a subproblem II. The former minimizes system frequency deviation from nominal value and the latter voltage violation of load buses. The optimization problem is solved by a reduced gradient technique which can handle a great number of inequality constraints more easily. It has been verified that the use of the proposed algorithm for IEEE 14 bus system alleviates the obstacles efficiently during the viability crisis.

  • PDF