• 제목/요약/키워드: Noise benefit cost

검색결과 24건 처리시간 0.02초

Adjusting the Retry Limit for Congestion Control in an Overlapping Private BSS Environment

  • Park, Chang Yun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권6호
    • /
    • pp.1881-1900
    • /
    • 2014
  • Since 802.11 wireless LANs are so widely used, it has become common for numerous access points (APs) to overlap in a region, where most of those APs are managed individually without any coordinated control. This pattern of wireless LAN usage is called the private OBSS (Overlapping Basic Service Set) environment in this paper. Due to frame collisions across BSSs, each BSS in the private OBSS environment suffers severe performance degradation. This study approaches the problem from the perspective of congestion control rather than noise or collision resolution. The retry limit, one of the 802.11 attributes, could be used for traffic control in conjunction with TCP. Reducing the retry limit causes early discard of a frame, and it has a similar effect of random early drops at a router, well known in the research area of congestion control. It makes the shared link less crowded with frames, and then the benefit of fewer collisions surpasses the penalty of less strict error recovery. As a result, the network-wide performance improves and so does the performance of each BSS eventually. Reducing the retry limit also has positive effects of merging TCP ACKs and reducing HOL-like blocking time at the AP. Extensive experiments have validated the idea that in the OBSS environment, reducing the retry limit provides better performance, which is contrary to the common wisdom. Since our strategy is basically to sacrifice error recovery for congestion control, it could yield side-effects in an environment where the cost of error recovery is high. Therefore, to be useful in general network and traffic environments, adaptability is required. To prove the feasibility of the adaptive scheme, a simple method to dynamically adjust the value of the retry limit has been proposed. Experiments have shown that this approach could provide comparable performance in unfriendly environments.

목표지향적 정보처리에서 무의식적 사고의 효과 (The Effect of Unconscious Thought on Goal-Dependent Decision Making)

  • 김민정;이영애
    • 인지과학
    • /
    • 제22권4호
    • /
    • pp.405-427
    • /
    • 2011
  • 원자력과 같은 과학기술 정보를 처리할 때 무의식적 사고가 어떤 영향을 미치는지 알아보았다. 원자력의 위험과 이익을 의식적으로 비교하면서 결론에 이르는 일반적인 방법에서 벗어나, 무의식적 사고 과정을 거치는 방법으로 올바른 판단이 가능한지를 검토하였다. 참여자들은 원자력에 관한 정보를 제공받고 가장 긍정적인 기사와 부정적인 기사를 판단하였다. 결정을 내리기 전 무의식적 사고 조건의 참여자들은 방해 과제로 이전 숫자를 기억하는 과제(2-back task)를 하고, 의식적 사고 조건의 참여자들은 매우 신중하게 생각하고, 즉각 조건의 참여자들은 즉시 판단하였다. 무의식적 사고의 효과를 극대화하기 위해 실험 1에서 이전 연구들을 분석하여 실험 재료와 절차를 조정하고, 정보와 소음을 함께 제시하여 참여자들의 판단에 영향을 미치는 의식적 처리를 부하시켰으나, 무의식적 사고의 효과가 관찰되지 않았다. 실험 2에서 정보를 제공하기 전이 아니라 정보를 모두 제공한 후 과제의 목적을 알려주어 무의식적 사고의 목표지향적 특성을 부각시켰을 때 무의식적 사고의 효과가 관찰되었다. 이러한 결과는 판단 과정에서 과제의 목적을 분명히 제시하면 무의식적 사고가 적극적으로 활용됨을 시사한다.

  • PDF

공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001-)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 -)

  • 정광섭;김민수;김용찬;박경근;박병윤;조금남
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.