• Title/Summary/Keyword: Noise barrier

Search Result 291, Processing Time 0.024 seconds

Ag-sheathed Bi2223 tape의 교류손실 저감을 위한 oxide barrier의 형성에 관한 연구 (Preparation of oxide barrier on Ag-sheathed Bi2223 tape for the reduction of AC loss)

  • 이세종;이득용;배성규;예경환;송요승
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.149-152
    • /
    • 2002
  • SrZrO3 resistive oxide barriers on Ag sheathed Bi2223 tapes prepared by the sol-gel and dip coating method were evaluated with an aid of Taguchi method and orthogonal arrays to elucidate the effects of experimental parameters, such as ratio of starting solution, amount of additives, and heat treatment temperature and time on the properties of the thin films. Six experimental parameters were selected and then Ll8(21x37) orthogonal arrays were constructed. Finally, SEM and XRD results were related to signal to noise (S/N) ratio to evaluate the optimized experimental condition.

  • PDF

도로변 방음 수림대 유형별 시뮬레이션 모형개발 및 평가 (Model Development and Appraisal by Visual Simulation about Soundproof Grove Types of Street Side)

  • 김성균;정태영
    • 농촌계획
    • /
    • 제11권2호
    • /
    • pp.59-69
    • /
    • 2005
  • Because of increasing numbers of cars many highways are being constructed lively, and the noise of passing cars has influenced surrounding areas. In consideration of this, some alternatives and researches for soundproof facilities are proceeding, but aesthetic approach hasn't been considered. Therefore, this research is focused on soundproof effects for each types, effectual simulation methods, visual assessment and estimation between the landscape before simulation and the landscape after. Soundproof facilities are divided largely by the soundproof barrier, the soundproof mounding, the soundproof grove. The soundproof grove has three main function. First, leaves and branches absorbs sound vibrations. Second, leaves absorbs sound, and branches obstruct sounds. Third, by means of sounds of shaking leaves, forest can offset noises. This research was proceeded by means of classification of soundproof grove types and investigation of visual simulation methods. We made visual simulation for each types, and estimated the landscape for each types.

도시철도 차량기지의 기반녹화에 적합한 방수시스템 선정을 위한 환경 조건 분석 (Analysis of Field Condition for Proper Waterproofing Materials applied to Green Roof System for Depot)

  • 민광만;권시원;최성민;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.127-131
    • /
    • 2006
  • Depot have a lagged behind structure in the side of building up the view. With this reason, people have been recognized depot as hatred facility causes to have car noise, air pollution. In the other hand, depot become a underground and complex facility as a higher-value added building, and moreover, it need to understand the environment that depot structure have a specific field condition to apply green roof system. 1) Analysis proper waterproofing material and root barrier apply to depot need root penetrating test method 2) Suggest root barrier and waterproofing material relate to maintain and construction for green roof system 3) Construction condition for depot have crack movement of structure by vehicle vibration and root penetrating force by plant growth

  • PDF

400 km/h 고속철도 환경소음저감을 위한 선로 변 벽체 상단장치개발에 관한 연구 (A Study on the Device Installed on the Barrier for The Environmental Noise Reduction in 400 km/h High Speed Railway)

  • 장강석;김영찬;서효선;최찬용;박준홍
    • 대한환경공학회지
    • /
    • 제39권12호
    • /
    • pp.679-684
    • /
    • 2017
  • 고속열차의 설계 및 운행기술이 발전하면서 고속철도의 운행속도가 빠르게 증속되고 있다. 반면 증속 시 발생하는 소음으로 인해 고속철도 연변의 주거지역 등에서는 많은 소음문제가 발생하고 있으며, 고속철도 소음에 대한 민원도 지속적인 증가추세에 있다. 향후 고속철도가 원활히 설계속도대로 운행되기 위해서는 고속철도의 방사소음특성에 적합한 소음예측기술 및 저감기술이 개발되어야 한다. 이와 같은 요구에 부합하기 위해, 400 km/h 고속철도 인프라 연구가 수년에 걸쳐 진행되었다. 이 연구를 통해 신뢰성을 갖는 고속철도 소음예측평가 기술이 개발되었고, 현재 소음저감기술의 단점을 극복하기 위한 핵심방음장치가 개발되었다. 본 연구의 궁극적인 목적은 고속철도 환경소음을 줄이기 위해 개발된 선로 변 벽체 상단에 설치되는 상단장치의 소음성능평가 및 풍압안전성 검증에 관한 것이다.

군 소화기 사격장 소음측정 및 소음저감 방안 평가 (Measurement of Noise and Evaluation of Noise Control Methods for Military Rifle Shooting Ranges)

  • 이상우;김희석;정상조
    • 한국군사과학기술학회지
    • /
    • 제12권1호
    • /
    • pp.123-132
    • /
    • 2009
  • Civil petitions and law suits against the military rifle shooting noise have been increased because many military shooting ranges are located near civilian residential area. In order to solve the noise problems, military have devised various methods. In this study, propagation properties of rifle shot through atmosphere were investigated. The military rifle shooting noise level at 5m from muzzle was between $l14{\sim}120dB$ in all directions. The noise level loom both backward and sideward away from system firing range consisting lines of 8 shooting locations were 90dB, when shots were all fired within 10 seconds. At present some of military bases established sound barriers, muzzle enclosures, silencers, and indoor shooting ranges to reduce noises and these prevention methods can reduce noise by $5{\sim}20dB,\;5{\sim}9dB,\;5{\sim}13dB,\;40{\sim}50dB$, respectively. Even though indoor shooting range has the best performance, it requires very expensive construction cost and has short length between target and shooter. In comparison, muzzle enclosure is cheap, but because it is installed in fixed position it can only be used in one shooting position. Therefore a commander should select appropriate methods to reduce military rifle shooting noise considering distance from residential area to the range, mission of military training, budget, etc.

Comparison of Transfer Function Method and Reverberation Room Method in Measuring the Sound Absorption Coefficient of Rice Straw Particle Mat

  • Kang, Chun-Won;Jang, Eun-Suk;Jang, Sang-Sik;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권4호
    • /
    • pp.362-367
    • /
    • 2018
  • This study estimates the sound absorption capability of rice straw particle mats by two methods: the transfer function method and the reverberation room method. In the reverberation method, the central frequency was set to the one-third octave band in the 100-5000 Hz range; in the transfer function method, the frequency range was 500-6400 Hz. Both methods yielded similar noise reduction coefficients of the rice straw mats. The noise reduction coefficient was approximately 0.8, indicating a high sound-absorption property of the mats. Therefore, rice straw matting is a suitable candidate material for sound-barrier walls against highway noise.

위성 발사체 탑재부 저주파 음향 모드 제어를 위한 공명기 배치 설계 (Design of Acoustic Resonator Array for Low Frequency Mode Control of Launch Vehicle)

  • 서상현;박순홍;장영순;이영무;조광래
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.521-524
    • /
    • 2005
  • To protect a satellite and electronic equipment from the acoustic loads generated by rocket propulsion system, many launch vehicle use acoustic blanket. Most high frequency region of the acoustic loads is reduced by nose fairing skins and acoustic barrier, but low frequency region is not. In order to control low frequency acoustic mode, we designed away resonator panel which was made of composite materials. This paper shows the absorption coefficient measurement result of resonator and SPL(Sound Pressure Level) reduction by using resonators in a rectangular cavity for experiment. Proper arrangement of acoustic resonators at each mode reduce effectively SPL around the satellite through changing boundary condition.

  • PDF

지뢰폭압 방호용 V형 구조물의 거동에 대한 상사법칙 연구 (A Study of Scaling Law for the Response of V-shape Structure Protecting Landmine)

  • 김동규
    • 한국소음진동공학회논문집
    • /
    • 제25권5호
    • /
    • pp.337-344
    • /
    • 2015
  • As many of armored vehicles are seriously exposed to threat of IEDs(Improvised Explosive Devices) in the Afghanistan war and the Iraq war. V-shaped military vehicles are deeply studied in order to protect crews and mounted soldiers against land mines. Generally the experiment on full-scaled V-shaped structure needs excessively high cost, which becomes a huge barrier to study. In this paper, we explore the possibility to make a half-scaled model of the V-shaped structure by using the geometric similarity scaling. We demonstrate the geometric similarity scaling between the original model and the half-scaled model is established on the momentum and deflections of structure via computer simulations and experiments. At this stage, we conduct only numerical analysis of predicting vibration of V-shaped structure because measuring vibration of structure is difficult in the mass-explosion experiment, which is remained as future work.

H 파일과 프리캐스트 콘크리트로 형성된 벽체의 횡저항성능에 대한 실험적 연구 (An Experimental Study on Lateral Load Resistance of a Wall Structure Composed of Precast Concrete and H-Pile)

  • 서동주;강덕만;이현기;문도영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권3호
    • /
    • pp.9-17
    • /
    • 2020
  • 이 연구의 목적은 프리캐스트 콘크리트 벽체와 H-pile로 구성된 벽체구조의 횡하중저항 성능을 평가하는 것이다. 이러한 형태의 구조는 옹벽 및 방음벽 기초 구조물로 사용된다. 실제 크기의 목업시험체를 설계하였으며, 실험체를 제작하였다. 대상 구조체의 설계횡하중은 54.6kN이다. 실제 현장에서 6.5m의 파일과 유사한 변형 프로파일을 갖는 실험체의 파일의 길이를 이론적으로 결정하였으며, 1.5m로 제작하였다. 실험중 벽체의 횡방향 변위가 파일의 변형률을 모니터링 하였으며, 균열의 발생을 육안 조사하였다. 실험으로부터 평가된 하중 및 변형 능력을 설계능력과 비교하였다. 실험결과는 설계하중을 저항하는데 충분한 성능을 보유하고 있음을 나타냈다.

시험방법에 따른 흡음률 비교 (Comparison of Absorption Coefficient according to Test Methods)

  • 이재원;구진회;박형규;강대준
    • 한국소음진동공학회논문집
    • /
    • 제17권5호
    • /
    • pp.373-378
    • /
    • 2007
  • Today, the use of the sound absorptive material is increasing to improve the room acoustics in the auditorium and music hall, etc. Usually, the sound absorption materials have been used to enhance the performance of a noise barrier and improve the room acoustics in construction site. Generally, the sound absorbtion coefficients are the most important factor reflecting the sound absorbtion performance. There are two methods to measure the sound absorption coefficient. The first one is the reverberation room method, and the second is the impedance tube method. In this study, we measure the sound absorbtion coefficients using these two methods, and then we compared the results of the sound absorbtion coefficients to look into the difference of results between reverberation room method and impedance tube method. Also we compared the results of the sound absorbtion coefficients with respect to the size of sample and the volume of reverberation room. From the experiment, we could see that the sound absorbtion coefficients are measured equally for different sample size. But the sound absorbtion coefficients are measured differently according to test methods and test conditions.