• 제목/요약/키워드: Noise and vibration test

검색결과 1,768건 처리시간 0.027초

가속주행하는 오토바이 흡배기계 시스템의 소음 저감에 관한 연구 (Study on the Intake/Exhaust Noise Reductions of Motorcycle Pass-by Noise)

  • 김봉기;김재승;김상렬;이상문;이태원;박근태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.871-875
    • /
    • 2001
  • Evaluation of the contribution of each pass-by noise source to the overall pass-by noise is an important issue for reduction of pass-by noise. A lead-wrapping test for analyzing pass-by noise of motorcycle is used to identify the principal noise sources of the pass-by noise in this study. Lead-wrapping test is employed and the contribution analysis is carried out. Based on the contribution analysis of each pass by noise source from the action of the prior tests, the design modifications of intake/exhaust systems were performed for reducing the pass-by noise. Finally, the pass-by noise test based on ISO362 was carried out to verify the noise reduction.

  • PDF

15만 파운드급 테스트 셀을 이용한 엔진성능 시험기술 (Aircraft Engine Performance Test Technologies by 150K lbf Thrust Test Cell)

  • 김우철;김철;김상백
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.180-187
    • /
    • 2017
  • 항공기 엔진 지상 성능시험을 위한 15만 파운드 급 Test 설비를 구축하기 위해 Test Cell Type, Cell Flow, Cell Bypass Ratio, Approach Velocity, Cell Depression, Front Cell Distortion, Noise 및 Vibration 등의 주요 설계 목표를 설정 하였고, 설비 완공 후 최종 성능검사를 통해 목표 값을 충족하는 성능 데이터를 획득할 수 있었다.

  • PDF

환형소결체 하나로 조사시험용 무계장 캡슐의 연구로 설치 적합성시험 (Compatibility test of a non-instrumented irradiation test capsule for the HANARO test reactor)

  • 이강희;김대호;전태현;김형규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.226-229
    • /
    • 2008
  • To investigate an in-pile behavior of the newly developed DUO fuel pellet, the irradiation test will be carried out in the domestic test reactor. Irradiation test capsule for the HANARO reactor, which is a specially designed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this study, a pressure drop, a flow-induced vibration and a short-term endurance test for the newly developed non-instrumented test capsule were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin.

  • PDF

공동주택 월풀욕조의 소음진동 특성 및 저감 방안 (The properties of noise and vibration in Whirlpool bath and plan for its reduction)

  • 배상환;이병권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.506-510
    • /
    • 2005
  • This study shows work on the properties of noise and vibration in Whirlpool bath and plan for its reduction. Totally through 3 steps. we found out the properties of noise and vibration. various anti-vibration design for an effeciency test is conducted. By Anti-vibration for the pump causing vibration, about 4dB(A) was reduced. Moreover. by anti-vibration construction fixing the bathtub frame. about 3db(A) could be reduced. In the case of anti-vibration construction about the wall around the bathtub. and spreading damping paint on the bathtub. the noise was reduced.

  • PDF

선반 기어박스의 진동.소음 분석과 저감에 관한 연구 (A Study on Vibration and Noise Reduction of a Lathe Gear Box)

  • 박선균;최영휴;배병태;정택수;김청수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.552-558
    • /
    • 2001
  • When operating lathe gear box which is equipped with geared transmission, it sometimes generates loud noise and excessive vibrations. In order to identify their causes, in this study, torsional and lateral vibration characteristics including critical speeds of the gear transmission system are firstly analyzed using lumped parameter models. Natural frequencies and mode shapes of the gear box structure are also analyzed by using the modal test. Furthermore, measured vibration and noise signals during operations are analyzed and compared with theoretical analysis results. After all, it is concluded that the primary cause of the excessive noise and vibrations is the resonance between gear meshing frequency including its side bands, the frequencies of shaft bending and torsional vibrations, and the natural frequencies of the gear box structure. Consequently the noise and vibration levels are greatly reduced by avoiding resonance between the natural frequencies and gear meshing frequencies through the rearrangement of the gears on the transmission shaft without any gear ratio change.

  • PDF

항공용 마운트의 개발과 시뮬레이션 (The Development & Simulation for the Isolation Mount installed in Aircraft)

  • 전희호;박재민;이승준
    • 한국소음진동공학회논문집
    • /
    • 제20권3호
    • /
    • pp.223-228
    • /
    • 2010
  • The mount which is used in military airplane should be operated in various situations such as vibration, shock and temperature. The recent mounts cost a lot and take much time to replace when they broke down. That's why new mount was produced in domestic by reverse engineering and the product has been proved its performance through environment test regarding vibration and shock. According to simulation of dynamic characteristics on vibration and shock, the result turns out to be similar to the result of the environmental test with an error of within 10 percent. As a result this research, a draft of the military aviation mount designing program is arranged.

풍력발전기 소음 성능 실증 (Noise Performance Test and Evaluation of a Wind Turbing Generator)

  • 김석현;김태형;박무열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.241-245
    • /
    • 2005
  • This study introduces the wind turbine (W/T) noise evaluation procedure required in the international standard (IEC 61400-11) and monitoring system for the evaluation. Noise emission characteristics of a 750kW W/T generator is investigated. Test and evaluation are performed on J48 W/T model which is under operation in Daekwanryung Wind Test Site. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level and tonality of the W/T are estimated under the wind speeds required by the international standard.

  • PDF

A Study on the Noise and Vibration Analysis of 200kW PMSM for Electric Propulsion Ship

  • Cho, Yang-Uk;Kang, Gyu-Hong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권4호
    • /
    • pp.389-393
    • /
    • 2014
  • This paper presents one of the methods for design to reduce the noise and vibration of 200kW motor for electric propulsion ship. One of the important factors affecting vibration of the motor is the resonance. The natural frequency and natural mode of the 200kW motor is analyzed by using FEM tool and impact test equipment to avoid the resonance. Also, compare FEM result with impact test result to make a reliable FE model of 200kW motor. In order to find out the effect of the noise and vibration of the motor by electromagnetic excitation force, conduct electromagnetic-structure coupled analysis. These characteristics are much useful to design 200kW motor for electric propulsion ship.

가진기의 동적 거동 해석 (Analysis on the Dynamic Behavior of Shaker)

  • 한상보;김윤환;송장규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.81-85
    • /
    • 1997
  • It is a well known fact that the exciter used in the vibration test interacts with the test structure and thus influences the test results. A two degree of freedom model of exciter is suggested and the vibration parameters of this model is experimentally extracted. According to this experimental results, the vibration parameters of the exciter can vary with respect to the test structure as well as the stinger used in the connecting mechanism. It is also found that the vibration parameters provided by the manufacturer can not be accurate and these parameter values should be revaluated based on the test environments.

  • PDF

발파공법에 따른 진동 및 소음 분석 (Vibration and Noise Analysis According to Blasting Method)

  • 김민혁
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.150-151
    • /
    • 2022
  • Blasting is a method that uses explosives to crush the ground. This method is a highly efficient ground cleaning method that can secure high efficiency in a short time. However, explosions can damage local properties and produce high noise and vibration. Therefore, it is important to be careful because there are disadvantages such as the occurrence of many complaints from the surrounding area. In this paper measured and analyzed the noise and vibration generated during blasting at the blasting site in Korea. The noise and vibration generated during blasting were measured by ES03303.2b and ES03402.2a at a distance of 6 m, 12 m from the blasting point. As a result of the measurement, there was little difference between small and medium scale except for precision vibration blasting at a distance of 6m, but noise difference according to blasting scale was evident at a distance of 12m. As a result of the measurement, the maximum noise level was reduced to 5.5 dB(A) and the vibration level was reduced to 7.7 dB(V). In the future, the reliability of the test results can be further improved through additional tests, and it is judged that noise and vibration prediction models based on blasting methods, amount of charge, measuring distance, etc. can be developed.

  • PDF