• Title/Summary/Keyword: Noise Robust

Search Result 1,308, Processing Time 0.028 seconds

Infrared Visual Inertial Odometry via Gaussian Mixture Model Approximation of Thermal Image Histogram (열화상 이미지 히스토그램의 가우시안 혼합 모델 근사를 통한 열화상-관성 센서 오도메트리)

  • Jaeho Shin;Myung-Hwan Jeon;Ayoung Kim
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.3
    • /
    • pp.260-270
    • /
    • 2023
  • We introduce a novel Visual Inertial Odometry (VIO) algorithm designed to improve the performance of thermal-inertial odometry. Thermal infrared image, though advantageous for feature extraction in low-light conditions, typically suffers from a high noise level and significant information loss during the 8-bit conversion. Our algorithm overcomes these limitations by approximating a 14-bit raw pixel histogram into a Gaussian mixture model. The conversion method effectively emphasizes image regions where texture for visual tracking is abundant while reduces unnecessary background information. We incorporate the robust learning-based feature extraction and matching methods, SuperPoint and SuperGlue, and zero velocity detection module to further reduce the uncertainty of visual odometry. Tested across various datasets, the proposed algorithm shows improved performance compared to other state-of-the-art VIO algorithms, paving the way for robust thermal-inertial odometry.

An Efficient Approach for Noise Robust Speech Recognition by Using the Deterministic Noise Model (결정적 잡음 모델을 이용한 효율적인 잡음음성 인식 접근 방법)

  • 정용주
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.6
    • /
    • pp.559-565
    • /
    • 2002
  • In this paper, we proposed an efficient method that estimates the HMM (Hidden Marke Model) parameters of the noisy speech. In previous methods, noisy speech HMM parameters are usually obtained by analytical methods using the assumed noise statistics. However, as they assume some simplication in the methods, it is difficult to come closely to the real statistics for the noisy speech. Instead of using the simplication, we used some useful statistics from the clean speech HMMs and employed the deterministic noise model. We could find that the new scheme showed improved results with reduced computation cost.

A Double Loop Control Model Using Leaky Delay LMS Algorithm for Active Noise Control (능동소음제어를 위한 망각형 지연 LMS 알고리듬을 이용한 이중루프제어 모델)

  • Kwon, Ki-Ryong;Park, Nam-Chun;Lee, Kuhn-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.28-36
    • /
    • 1995
  • In this paper, a double loop control model using leaky delay LMS algorithm are proposed for active noise control. The proposed double loop control model estimates the loudspeaker characteristic and the error path transfer function with on-line using only gain and acoustic time delay to reduce computation burden. The control of error signal through double loop control scheme makes the more robust cntrol system. The input signal of filter to estimate acoustic time delay is used difference between input signal of input microphone and adaptive filter output. And also, in nonstationary environments, the leaky delay LMS algorithm is employed to counteract parameter drift of delay LMS algorithm. For practical noise signal, the proposed double loop control model reduces noise level about 12.9 dB.

  • PDF

An Adaptive Active Noise Cancelling Model Using M-Channel Subband QMF Filter Banks (M-채널 서브밴드 QMF 필터뱅크를 이용한 적응 능동소음제거 모델)

  • 허영대;권기룡;문광석
    • Journal of Korea Multimedia Society
    • /
    • v.2 no.1
    • /
    • pp.30-37
    • /
    • 1999
  • A wideband active noise cancelling system involves adaptive filters with hundreds of taps. The computational burden required with these long adaptive filters. This paper presents active noise cancelling system using M-channel QMF filter banks in which the adaptive weights are computed in subbands. The analysis and synthesis filter banks use cosine-modulated pseudo QMF filters. The reference signal for on-line identification of error path transfer characteristics is used to difference signal between the output of adaptive filters and the output of lowpass subband filters. The proposed adaptive subband filter bank suggests robust active noise cancelling system retaining the computational complexity and convergence speed advantaged of subband processing.

  • PDF

The Robust Estimation of Fundamental Matrix Using the SSOR (SSOR을 이요한 강인한 F-행렬의 추정)

  • Kim, Hyo-Seong;Nam, Gi-Gon;Jeon, Gye-Rok;Lee, Sang-Uk;Jeong, Du-Yeong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.1
    • /
    • pp.40-48
    • /
    • 2002
  • Three-Dimensional scene reconstruction from images acquired with different viewpoints is possible as estimating Fundamental matrix(F-matrix) that indicates the epipolar geometry of two images. Correspondence points required to calculate F-matrix of two images include noise such as miss matches, so generally it is hard to calculate F-matrix accurately. In this paper, we classify noise into two types; outlier and minute noise. we propose SSOR algorithm that estimate F-matrix effectively. SSOR algorithm is rejecting outlier step by step in a noise environment. To evaluate the performance of proposed algorithm we simulated with synthetic images and real images. As a result of simulation we show that proposed algorithm is better than conventional algorithms.

Implementation of Extended Kalman Filter for Real-Time Noncontact ECG Signal Acquisition in Android-Based Mobile Monitoring System

  • Rachim, Vega Pradana;Kang, Sung-Chul;Chung, Wan-Young;Kwon, Tae-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • Noncontact electrocardiogram (ECG) measurement using capacitive-coupled technique is a very reliable long-term noninvasive health-care remote monitoring system. It can be used continuously without interrupting the daily activities of the user and is one of the most promising developments in health-care technology. However, ECG signal is a very small electric signal. A robust system is needed to separate the clean ECG signal from noise in the measurement environment. Noise may come from many sources around the system, for example, bad contact between the sensor and body, common-mode electrical noise, movement artifacts, and triboelectric effect. Thus, in this paper, the extended Kalman filter (EKF) is applied to denoise a real-time ECG signal in capacitive-coupled sensors. The ECG signal becomes highly stable and noise-free by combining the common analog signal processing and the digital EKF in the processing step. Furthermore, to achieve ubiquitous monitoring, android-based application is developed to process the heart rate in a realtime ECG measurement.

A Study of Digital filter for context-awareness using multi-sensor built in the smart-clothes (멀티센서 기반 스마트의류에서 상황인지를 위한 디지털필터연구)

  • Jeon, Byeong-chan;Park, Hyun-moon;Park, Won-Ki;Lee, Sung-chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.911-913
    • /
    • 2013
  • The user's context awareness is important to the reliability of sensors data. The sensor data is constantly change to external temp, internal& external environment and vibration. This noise environment is affecting that the data collected information from sensors. Of course this method of digital filter and inference algorithm specifically request for the use of ripple noise and action inference. In this paper, experiment was a comparison of the KF(Kalman Filter) and WMAF(Weight Moving Average Filter) for noise decrease and distortion prevention according to user behavior. And, we compared the EWDF(Extended Weight Dual Filter) with several filer. In an experiment, in contrast to other filter, the proposed filter is robust in a noise-environment.

  • PDF

Fast Noise Reduction Approach in Multifocal Multiphoton Microscopy Based on Monte-Carlo Simulation

  • Kim, Dongmok;Shin, Younghoon;Kwon, Hyuk-Sang
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.421-430
    • /
    • 2021
  • The multifocal multiphoton microscopy (MMM) enables high-speed imaging by the concurrent scanning and detection of multiple foci generated by lenslet array or diffractive optical element. The MMM system mainly suffers from crosstalk generated by scattered emission photons that form ghost images among adjacent channels. The ghost image which is a duplicate of the image acquired in sub-images significantly degrades overall image quality. To eliminate the ghost image, the photon reassignment method was established using maximum likelihood estimation. However, this post-processing method generally takes a longer time than image acquisition. In this regard, we propose a novel strategy for rapid noise reduction in the MMM system based upon Monte-Carlo (MC) simulation. Ballistic signal, scattering signal, and scattering noise of each channel are quantified in terms of photon distribution launched in tissue model based on MC simulation. From the analysis of photon distribution, we successfully eliminated the ghost images in the MMM sub-images. If the priori MC simulation under a certain optical condition is established at once, our simple, but robust post-processing technique will continuously provide the noise-reduced images, while significantly reducing the computational cost.

Model adaptation employing DNN-based estimation of noise corruption function for noise-robust speech recognition (잡음 환경 음성 인식을 위한 심층 신경망 기반의 잡음 오염 함수 예측을 통한 음향 모델 적응 기법)

  • Yoon, Ki-mu;Kim, Wooil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.1
    • /
    • pp.47-50
    • /
    • 2019
  • This paper proposes an acoustic model adaptation method for effective speech recognition in noisy environments. In the proposed algorithm, the noise corruption function is estimated employing DNN (Deep Neural Network), and the function is applied to the model parameter estimation. The experimental results using the Aurora 2.0 framework and database demonstrate that the proposed model adaptation method shows more effective in known and unknown noisy environments compared to the conventional methods. In particular, the experiments of the unknown environments show 15.87 % of relative improvement in the average of WER (Word Error Rate).

Development of Real-time QRS-complex Detection Algorithm for Portable ECG Measurement Device (휴대용 심전도 측정장치를 위한 실시간 QRS-complex 검출 알고리즘 개발)

  • An, Hwi;Shim, Hyoung-Jin;Park, Jae-Soon;Lhm, Jong-Tae;Joung, Yeun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.280-289
    • /
    • 2022
  • In this paper, we present a QRS-complex detection algorithm to calculate an accurate heartbeat and clearly recognize irregular rhythm from ECG signals. The conventional Pan-Tompkins algorithm brings false QRS detection in the derivative when QRS and noise signals have similar instant variation. The proposed algorithm uses amplitude differences in 7 adjacent samples to detect QRS-complex which has the highest amplitude variation. The calculated amplitude is cubed to dominate QRS-complex and the moving average method is applied to diminish the noise signal's amplitude. Finally, a decision rule with a threshold value is applied to detect accurate QRS-complex. The calculated signals with Pan-Tompkins and proposed algorithms were compared by signal-to-noise ratio to evaluate the noise reduction degree. QRS-complex detection performance was confirmed by sensitivity and the positive predictive value(PPV). Normal ECG, muscle noise ECG, PVC, and atrial fibrillation signals were achieved which were measured from an ECG simulator. The signal-to-noise ratio difference between Pan-Tompkins and the proposed algorithm were 8.1, 8.5, 9.6, and 4.7, respectively. All ratio of the proposed algorithm is higher than the Pan-Tompkins values. It indicates that the proposed algorithm is more robust to noise than the Pan-Tompkins algorithm. The Pan-Tompkins algorithm and the proposed algorithm showed similar sensitivity and PPV at most waveforms. However, with a noisy atrial fibrillation signal, the PPV for QRS-complex has different values, 42% for the Pan-Tompkins algorithm and 100% for the proposed algorithm. It means that the proposed algorithm has superiority for QRS-complex detection in a noisy environment.