• Title/Summary/Keyword: Noise Reflection

Search Result 290, Processing Time 0.023 seconds

Microwave Absorbing Properties of Fe-Si-Al Alloy Flaky Powder-Rubber Composites (Fe-Si-Al 합금 분말 · 고무 복합 자성체의 전파 흡수 특성)

  • Lee Kyung-Sub;Yoon Yeo-Choon;Choi Gwang-Bo;Kim Sung-Soo;Lee Jun-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.2 s.93
    • /
    • pp.228-234
    • /
    • 2005
  • A magnetic composite as noise absorber of quasi-microwave band was developed. The Fe-Si-Al alloy powder were forged by attrition mill to get flaky shape. The magnetic composite sheet was fabricated in which powders are dispersed in polymer and aligned in the direction perpendicular to electromagnetic wave propagation. The permittivity of magnetic composite is increased as forging time increasing, while the permeability is decreased slightly. The maximum attenuation peak of reflection loss is shifted to lower fiequency range as milling time increasing, and the value of maximum attenuation peak is to get smaller gradually. From these result, we could designed a noise absorber sheet (t=1.0 mm) for quasi-microwave band, which is impedance matched at 1.4 GHz with respect to -8.2 dB reflection 1055.

Total-internal-reflection Holographic Photo-lithography by Using Incoherent Light (비가간섭광을 이용한 내부전반사 홀로그래픽 리소그라피)

  • Lee, Joon-Sub;Park, Woo-Jae;Lee, Ji-Whan;Song, Seok-Ho;Lee, Sung-Jin
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.334-338
    • /
    • 2009
  • Recently, with increasing demand for flat-panel display product, methods for large area patterning are required. TIR (total internal reflection) holographic photo-lithography isstudied as one of the methods of large area lithography. In conventional TIR holography, light sources for hologram recording and image reconstruction are coherent beams such as laser beams. If the image is reconstructed with an incoherent light source such a UV lamp, the image noise from the coherence of light will be reduced and the UV lamp will be a better light source for large area exposure. We analyzed the effect of spectral bandwidth and angular bandwidth of the light source in image reconstruction and verified image blurring with experiments. For large area patterning which has micro-scale line width, it is expected that TIR holographic photo lithography by UV lamp will become a low-noise and low-priced technique.

A Case Study for Analysis on Present Condition and Cause of Indoor Noise in University Cafeteria (대학교 학생식당의 실내소음 실태 및 원인 분석 사례연구)

  • Choi, Yoon-Jung;Lee, Seon-A;Kim, Hye-Kyeong
    • Journal of the Korean housing association
    • /
    • v.18 no.5
    • /
    • pp.85-91
    • /
    • 2007
  • This is a case study for improving the sound environmental quality of cafeteria in university campus. The purpose of the study is to find out the present condition of physical level, type, and cause of indoor noise of cafeteria in university campus by comparison with a restaurant near campus. Research methods were field survey and questionnaire survey. Field survey was consisted of measurement on equivalent and instant noise level and observation on noise type. Respondents of questionnaire survey were 60 students using subject cafeteria or restaurant. Surveys were carried out in the 8th and in the 14th of December 2005. The results are as follows. 1) Indoor noise levels of the cafeteria were measured as $67.2{\sim}76.6$ (average 73.3) dB(A)Leq5min and $60.3{\sim}90.5$ (average 71.2) dB (A), exceeded the indoor noise recommended value of ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers). But noise levels of the restaurant were $61.6{\sim}70.4$ (average 66.9) dB(A)Leq5min and $59.8{\sim}70.6$ (average 64.9) dB(A). 2) The users's responses on major noise type in the cafeteria were 'noise by handling equipment and tableware', 'noise by moving chairs', and 'talcing noise', but 'taking noise' and 'background music' in the restaurant. 3) It was found that indoor noise level of the cafeteria was caused by sound reflection of finishing materials, noise diffusion by open type kitchen, and dragging noise of movable furniture.

The Acoustic Performance Measurement of Silencers in Reflective Field (반사파가 존재하는 음향장에서의 소음기의 음향성능 측정)

  • Lee, Seong-Hyun;Ih, Jeong-Guon;Choi, Won-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.625-628
    • /
    • 2005
  • Silencers are extensively used for reducing noise in an exhaust system of internal combustion Engine and fluid machineries. The prediction and measurement of the transmission loss as the acoustic performance of silencers are important in early design stage. In the measurement of transmission loss, the semi-anechoic terminations are general used for reducing unwanted effects by reflecting wave. However it is very hard to remove reflecting wave perfectly. So the research about the error made by reflecting wave is important. The analysis about errors made by reflections and modification techniques are proposed. For an application example, the diesel particulate filter (DPF) is chosen. The transmission loss of DPF is measured with and without considerations of reflecting wave.

  • PDF

Investigating the spatial focusing performance of time reversal Lamb waves on a plate with respect to input source location and the number of sensors (입력소스의 위치와 센서개수에 따른 평판에서의 시간반전램파의 공간집속성능 규명)

  • Seo, dae jae;Park, huyn woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.722-725
    • /
    • 2014
  • The spatial focusing of time reversal Lamb waves on a plate has attracted considerable attention for identifying the location of an input source. This study investigates the spatial focusing performance on a plate with respect to the number of piezoelectric (PZT) sensors for varying locations of input sources. In particular, a small number of PZT sensors produce spatial focusing through the virtual sensor effect due to reflection of Lamb waves at plate edges. The spatial focusing performance with respect to the number of PZT sensors is quantified in terms of signal to noise ratio through numerical simulation and its implication is discussed.

  • PDF

A Study on the Broadband Microwave LNA(Low Noise Amplifier) (초고주파용 대역 저잡음 증폭기에 관한 연구)

  • Lee, S.W.;Cheon, C.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.487-488
    • /
    • 1995
  • Broadband Microwave Low Noise Amplifier(LNA) is designed. The matching method using the broadband BPF(BandPass Filter) is introduced in this paper. This method is that the filter having the same reflection coefficient of Microwave GaAs FET in the desired bandwidth is located on the input stage of FET. The Simulated results is obtained that the $S_{21}$ and noise figure in 2.5GHz$\sim$9GHz, band are 8.5dB $\pm$ 1.5dB, 2.5dB $\pm$ 0.3dB respectively.

  • PDF

Pressure Ripple Reduction in Hydrostatic Transmissions by Using a Hydraulic Filter (맥동흡수용 유압필터에 의한 유압전동장치의 압력맥동 감쇠)

  • 김도태
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.3
    • /
    • pp.33-38
    • /
    • 2002
  • This paper deals with pressure ripple attenuation far separated-type Hydrostatic Transmission (HST) consisting ova variable axial piston pump connected in an open loop to a fried displacement axial piston motor. Pressure ripples in HST is major source of vibration which can lead to fatigue failure of components and cause noise. In order to reduce the pressure ripple, an annular tube tripe hydraulic filter is proposed to attenuate pressure ripples with the high frequencies components to achieve better noise reduction in HST. The basic principle of a hydraulic filter is allied to propagation of pressure wave, reflection, absorption in cross section of discontinuity and resonance in the hydraulic pipeline. It is experimentally shown that the hydraulic filter attenuates about 30∼40dB of pressure ripple with high frequencies. These results will assist in modeling and design of noise reduction in hydraulic control systems, and provide a means of designing a quieter HST.

Design of a Low Noise Amplifier for Wireless LAN (무선 근거리 통신망용 저잡음 증폭기의 설계)

  • 류지열;노석호;박세현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.6
    • /
    • pp.1158-1165
    • /
    • 2004
  • This paper describes the design of a two stage 1V power supply SiGe Low Noise Amplifier operating at 5.25㎓ for 802.lla wireless LAN application. The achieved performance includes a gain of 17㏈, noise figure of 2.7㏈, reflection coefficient of 15㏈, IIP3 of -5㏈m, and 1-㏈ compression point of -14㏈m. The total power consumption of the circuit was 7㎽ including 0.5㎽ for the bias circuit.

Partial field decomposition using beamforming-based NAH under reflective condition (반사파가 존재할 때 음향홀로그래피에서 빔형성 방법을 이용한 부분음장 분리)

  • 이원혁;강연준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1323-1328
    • /
    • 2001
  • The theory of NAH is based on the assumption of reflection free. However, it is not always possible to meet this condition in many practical cases. Thus, a decomposition of direct and reflected fields is needed to apply NAH to reflective condition for noise problems. In addition, the decomposition of direct and reflected field can give acoustic characteristics of reflecting surfaces. This paper presents that in this condition the decomposition can also be successfully done by MUSIC(Multiple Signal Classification) power method and beamforming method, and that numerical simulation and real experiments verify its performance.

  • PDF

Quiet Zone Generation by Absorption Materials (흡음재 배치를 이용한 정숙 공간 형성 방법)

  • Park, Joo-Bae;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.403-408
    • /
    • 2000
  • An acoustic field in a 3 dimensional enclosure is caused from interference between sound sources and the complex reflections from wall. Therefore, changing an acoustic property of wall such as admittance means generating another acoustic field. The purpose of this paper is utilizing the characteristic to make a quiet zone. First, this paper shows that the control material is essentially on the same road as active noise control(ANC). That is, we can consider the control material as the control source of ANC. However we cannot control the reflection strength of it. Second, through a numerical simulation, this paper shows that the position of the control material is an important variable of the control.

  • PDF