화장실 배수관에 따른 배수소음 평가 (Rating of Noise Emission by Plumbing system in Bathroom)

  • 정진연;이성호;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.923-927
    • /
    • 2003
  • The aim of this study is to investigate the characteristics and quantity of the noise reduction by pipe material, wrapped pipe with glass wool and installed pipe height The characteristics of noise emission from drain-pipes is as follows. The noise reduction pipe in PVC can reduce noise levels in 7-10㏈ and the cast-iron pipe can reduce in 14㏈compared with the normal PVC pipe. In these days, the glass wool was used for preventing the burst and the noise reduction. But the glass wool for wrapping pipe is not effective to the noise reduction. The characteristics of noise emission from various installed pipe height were measured As the ceiling space of the remodeled building was raised, the noise level was troubled by increasing of the vertical pipe length.

  • PDF

광대역 전달 소음저감을 위한 지능패널의 개발 (The development of piezoelectric smart panels for wide range transmission noise reduction)

  • 이중근;김재환;정재천;강영규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1273-1279
    • /
    • 2000
  • A new concept of piezoelectric smart panels for noise reduction in wide band frequencies is proposed and their possibility is experimentally investigated. The proposed panels are based on active and passive methods. They use piezoelectric smart structure technology for active noise reduction at low band frequencies and passive sound absorbing materials for mid-range of noise frequencies. To prove the concept of piezoelectric smart panels, an acoustic measurement experiment was performed. The smart panels exhibit a good noise reduction in middle and high frequency ranges due to the mass effects of absorbing materials or/and the air gap. The use of piezoelectric smart panel renders noise reduction large at resonance frequency. Another concept of smart panel that uses piezoelectric damping is experimentally investigated. Since piezoelectric dampings can reduce vibration and noise at resonance frequencies with simple shunt circuit, they have merits in terms of economy and simplicity. Dissipated energy method(DEM) is adopted to tune the shunt circuit precisely in piezoelectric dampings. Noise reduction at multiple resonance frequencies is demonstrated.

  • PDF

Implementation of Noise Reduction Methodology to Modal Distribution Method

  • Choi, Myoung-Keun
    • 한국해양공학회지
    • /
    • 제25권2호
    • /
    • pp.1-6
    • /
    • 2011
  • Vibration-based Structural Health Monitoring (SHM) systems use field measurements of operational signals, which are distorted by noise from many sources. Reducing this noise allows a more accurate assessment of the original "clean" signal and improves analysis results. The implementation of a noise reduction methodology for the Modal Distribution Method (MDM) is reported here. The spectral subtraction method is a popular broadband noise reduction technique used in speech signal processing. Its basic principle is to subtract the magnitude of the noise from the total noisy signal in the frequency domain. The underlying assumption of the method is that noise is additive and uncorrelated with the signal. In speech signal processing, noise can be measured when there is no signal. In the MDM, however, the magnitude of the noise profile can be estimated only from the magnitude of the Power Spectral Density (PSD) at higher frequencies than the frequency range of the true signal associated with structural vibrations under the additional assumption of white noise. The implementation of the spectral subtraction method to MDM may decrease the energy of the individual mode. In this work, a modification of the spectral subtraction method is introduced that enables the conservation of the energies of individual modes. The main difference is that any (negative) bars with a height below zero after subtraction are set to the absolute value of their height. Both noise reduction methods are implemented in the MDM, and an application example is presented that demonstrates its effectiveness when used with a signal corrupted by noise.

움직임 추정 보정을 이용한 잡음 제거 및 디인터레이싱 기법 (Noise reduction and De-interlacing with motion vector validation)

  • 정재한;양승준
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.149-152
    • /
    • 2003
  • This paper presents a method to find motion vectors that are closer to true motion with noisy images for simultaneous noise reduction and do-interlacing. The proposed method requires four interlaced field images: one noisy field image and three field images from which noise is already removed. The validation of motion provides accurate motion vectors and allows us to utilize them even in very noisy environment. The validated motion vectors are first used for the noise reduction, buffered and used later for the noise reduction and de -interlacing.

  • PDF

영상에 포함된 잡음의 분산 추정과 잡음제거 (Estimation of the Noise Variance in Image and Noise Reduction)

  • 김영화;남지호
    • 응용통계연구
    • /
    • 제24권5호
    • /
    • pp.905-914
    • /
    • 2011
  • 영상처리 분야에서 원래의 순수 이미지를 오염시키는 잡음을 제거하는 것은 매우 중요한 문제이다. 그러나 여러 가지 원인으로 인하여 발생하는 잡음의 발생을 완벽하게 막는 것은 현실적으로 불가능하다. 따라서 영상에 포함되어 있는 잡음을 제거하거나 최대한 줄이는 것이 매우 중요한 과제이다. 본 연구에서는 이미지를 오염시키고 있는 잡음의 상대적인 크기를 측정하여 잡음의 분산의 수준을 추정하고, 이를 영상처리 분야에서 자주 사용되는 잡음제거 기법인 시그마 필터에 응용하여 잡음을 효과적으로 제거하는 통계적 알고리즘을 제시하였다. 결론적으로, 잡음의 분산의 수준에 관계없이 본 연구에서 제안한 통계적 잡음제거 방법론을 통해 기존의 시그마 필터보다 현저하게 개선된 결과를 얻을 수 있었다.

방음 터널 설치에 따른 소음 저감 효과 연구 (A Study on Noise Reduction of Railway Noise by Noise Barrier)

  • 김다래;김태민;김정태;손정곤;박광현;류래언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.125-130
    • /
    • 2014
  • High speed railroad car and high-rise apartment with development of railway technology cause different problems of noise contrary to the previous generation. It is the most efficient noise reduction countermeasure but we studied that is the way on noise propagation with sound proof wall or sound proof tunnel around railroad. But if it were railroad on bridge, additional cost which is more expensive than installing one on the ground is needed. So sound insulation material considering reducing weight of recent soundproof facilities must be selected. It is in this study that predicted and analyzed acoustical and structural effect for noise reduction by installing soundproof tunnel. If it were departmentalized into additional study, could be able to expect noise reduction effect of sound proof tunnel establishment on the bridge.

  • PDF

산업용 로봇의 소음/진동 저감 연구 (A Study of Industrial Robot for the Noise and the Vibration Reduction)

  • 이광열;정진태;정두한;임흥순;김영환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.146-151
    • /
    • 2002
  • The object of this study is an examination of source of robot noise and reduction of the noise and the vibration for an industrial robot system. As the first step in our study, the noise and the vibration from the robot are measured by microphones and by accelerometers and the source of the noise and the vibration are proved to be from the gear, shaft, and housing from the experiments. The occurrence of the noise may be classified according into kinds, Finally base on the result of the experiments, we consider a countermeasure for reducing the noise and the vibration of robot system by the parametric study.

  • PDF

산업용 로봇의 소음/진동 저감 연구 (A Study of Industrial Robot for the Noise and the Vibration Reduction)

  • Lee, Kwangyal;Jintai Chung;Duhan Jung;Yim, Hueng-Soon;Kim, Young-Hwin
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.321.1-321
    • /
    • 2002
  • The object of this study is an examination of source of robot noise and reduction of the noise and the vibration for an industrial robot system. As the frist step in our study, the noise and the vibration from the robot are measured by microphones and by accelerometers and the source of the noise and the vibration are proved to be from the gear, shaft, and housing from the experiments. The occurrence of the noise may be classified according into kinds, Finally base on the result of the experiments, we consider a countermeasure fur reducing the noise and the vibration of robot system by the parametric study.

  • PDF

도시철도 터널내 흡음재 시험설치 및 소음저감효과 분석에 관한 연구 (A Study on an Analysis of Noise Reduction Effects using the tentatively Installed Sound-absorbing Materials in Metro Tunnel)

  • 홍철기;정이택;김병홍
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.125-131
    • /
    • 2008
  • This research tries to analyze and investigate the effects of the noise reduction test for the sound-absorbing materials installed tentatively on Metro Line 5. Though the noise reduction effects of each sound-absorbing material showed that there was about $2{\sim}5\;dB$ compared with before and after of the tentative installation, it shows that the noise reduction effects are reducing because of the section change condition such as dust absorption and the rail abrasion as time passes after the tentative installation. Also, many difficulties are occurring in the maintenance of the orbit facilities because of the installation of sound-absorbing materials. Though various abroad products for noise reduction are imported like this, the researches for the noise reduction effect increase for this and the improvement direction are being required because of the poor circumstance of the efficiency aspect compared to the economic investment effect because those are not suited to the character of domestic Metro.

  • PDF

바닥 구조물의 폼재 충전을 통한 고속철도 차량의 실내 소음 저감 연구 (Analysis of Interior Noise Reduction in High Speed Trains by Filling up with Form)

  • 김태민;김정태;김정수;김석현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.663-669
    • /
    • 2011
  • Since railway vehicle's improvements on speed and weight has caused interior noise, the passenger's convenience fell dramatically. Therefore many on-going researches are dedicated to reduce interior noise. In this study the analytical prediction of interior noise reduction has done through filling up the empty space using form and to modify the floor structure, which contributes highly with interior noises. Using Statistical Energy Analysis(SEA), the interior noise of the vehicles without the form filling on the floor structure and the vehicles with form filling and also a modified structure has been predicted. The selected percentage of form filling was 0, 50, 100% and through this research the analysis of noise reduction by form filling has been made. When floor structure has been filled with form, approximately 2 dB of noise reduction was observed and the difference of noise reduction level with 50 and 100% form filling was predicted to be very little. Through this study, the expectation of interior noise reduction in high speed trains is considered high.

  • PDF