• Title/Summary/Keyword: Noise Reduction(NR)

Search Result 10, Processing Time 0.03 seconds

Study on Dual-Energy Signal and Noise of Double-Exposure X-Ray Imaging for High Conspicuity

  • Song, Boram;Kim, Changsoo;Kim, Junwoo
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.160-169
    • /
    • 2021
  • Background: Dual-energy X-ray images (DEI) can distinguish or improve materials of interest in a two-dimensional radiographic image, by combining two images obtained from separate low and high energies. The concepts of DEI performance describing the performance of double-exposure DEI systems in the Fourier domain been previously introduced, however, the performance of double-exposure DEI itself in terms of various parameters, has not been reported. Materials and Methods: To investigate the DEI performance, signal-difference-to-noise ratio, modulation transfer function, noise power spectrum, and noise equivalent quanta were used. Low- and high-energy were 60 and 130 kVp with 0.01-0.09 mGy, respectively. The energy-separation filter material and its thicknesses were tin (Sn) and 0.0-1.0 mm, respectively. Noise-reduction (NR) filtering used the Gaussian-filter NR, median-filter NR, and anti-correlated NR. Results and Discussion: DEI performance was affected by Sn-filter thickness, weighting factor, and dose allocation. All NR filtering successfully reduced noise, when compared with the dual-energy (DE) images without any NR filtering. Conclusion: The results indicated the significance of investigating, and evaluating suitable DEI performance, for DE images in chest radiography applications. Additionally, all the NR filtering methods were effective at reducing noise in the resultant DE images.

Noise Reduction Method in consideration of bandwidth of Low Pass Filter (저역통과 필터의 대역폭을 고려한 잡음 제거 방법)

  • Yang, Jeong-Ju;Jang, Won-Woo;Kwak, Boo-Dong;Kang, Bong-Soon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.157-159
    • /
    • 2010
  • Most digital cameras apply a Charge Coupled Device(CCD) Sensor or a Complementary Metal Oxide Semiconductor(COMS) Sensor. And the images captured these sensors include unwanted noises. In this paper, we proposed a method of the Noise Reduction(NR) about noise reduction or recovery in the image. The proposed NR method is related to Bandwidth of the Low Pass Filter(LPF). For improvement of NR, we were changing the filter coefficient of the LPF. The results of simulations with various filter coefficients, [1 2 1] in the LPF and [-1 2 -1] in the High Pass Filter(HPF) have ideal frequency bandwidth and high performance. We proposed a filter coefficient [1 2 1] and [-1 2 -1] in the LPF and the HPF respectively.

  • PDF

A Study on the Noise Characteristics of noise occurred when medical examination in dental clinic

  • Ji, Dong-Ha;Lee, Yong-Gyoo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.12
    • /
    • pp.163-170
    • /
    • 2018
  • This study was conducted to investigate the effects of noise from dental clinics on workers and to establish a reduction plan. The noise generated by the treatment instrument(Ultrasonic scaler, Hand piece, 3-way syringe, Suction, Compressor) was measured in order to determine the characteristics(level, frequency) of the noise during medical treatment(Oral prophylaxis, Conservation treatment, Prosthesis treatment, Implant Scaling, Tooth eliminating). We also assessed the noise levels in dental clinic using evaluation indicators such as NR-curves and NRN. The results of the analysis showed that the noise generated during the treatment was 85dB(A) ~ 70dB(A) and that the high frequency component was dominant, which would affect the workers working at the dental clinic. The NR-curve analysis showed NR-67 to NR-83 and the high frequency components of 4kHz to 8kHz were predominant and far exceeded noise levels in the workplace. To minimize the noise damage of workers and to provide high quality medical service, it is necessary to establish countermeasures such as wearing a soundproof and periodic hearing tests.

Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear

  • Biabani, Azam;Aliabadi, Mohsen;Golmohammadi, Rostam;Farhadian, Maryam
    • Safety and Health at Work
    • /
    • v.8 no.4
    • /
    • pp.364-370
    • /
    • 2017
  • Background: Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Methods: Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV102). Results: The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically (p < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant (p > 0.05). Conclusion: This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.

Study on the noise reduction occurred to rotation in duct (덕트 회전체에서 발생하는 소음저감에 대한 연구)

  • Park, Hong-Ul;Kim, You-Jae;Park, Sung-Kwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.875-879
    • /
    • 2006
  • Noise reduction has become a major issue of the duct air-conditioners. This paper describes the reduction of noise and vibration of rotational slim duct system. The design of slim duct system is the most important point of noise reduction in terms of the motor of 2f line noise, resonance noise between forced frequency and natural frequency of Sirocco fan, unbalance noise of motor axis and the noise induced refrigerant. The noise of duct system is mainly measured from diffuser and bottom of duct. The optimal design was implemented after measuring the effect of noise and vibration in each part which is composed of duct system. In this paper, experimental results show that the main elements in air-conditioner duct design. These elements are anti-vibration rubber of motor, axis length of motor, rubber coupler, materials of sirocco fan and control method of motor which are the most vital factors in reducing noise.

  • PDF

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.

Algorithm of Adaptive Noise Reduction with Modified Sigma Filter for Reduction of Edge Blurring and Minute Noises (윤곽선 훼손 방지 및 미세잡음 제거를 위한 Modified Sigma Filter를 이용한 적응적 잡음 제거장치 알고리즘)

  • Yang, Jeong-Ju;Han, Hag-Yong;Yang, Hoon-Gee;Kang, Bong-Soon;Lee, Gi-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2261-2268
    • /
    • 2010
  • The information captured by imaging devices such as CCD or CIS may contain external noises through the processes of passing signals or storing images. In this paper, we propose a Modified Sigma Filter (MSF) algorithm to reduce such noises. In experiment, we verified that our MSF algorithm showed better performance in PSNR and 1D plot of simulation results compared with Gaussian Filter (GF), Local Sigma Filter (LSF). Tested images include random Gaussian Noises.

Comparision Between Noise Levels of Hospital Wards and the Nurses Efforts for Noise Management in Selected General Hospital (종합병원 병동별 간호사실의 소음정도와 간호사실들의 소음인지도 및 소음관리노력 비교)

  • Jung, Hyun-Wook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.174-182
    • /
    • 2001
  • This study was performed to find out the differences between noise levels of hospital wards and the nurses efforts for noise management in some general hospitals. The hospital wards selected were the intensive care unit(ICU), the emergency room(ER), the nursery room(NR), the internal medicine(IM), the general surgery(GS) among the 5 general hospitals located in Seoul. The data were collected from August 3 to September 13, 1999 through questionnaire survey and noise measurement in each nursing station of hospital wards. Data analysis was done by SPSS 8.0 package among the 305 questionnaires and 24 hours monitored noise levels. Frequency, Chi-square and ANOVA test were used. The study results were as belows: 1. The noise level measured by 24 hours monitoring survey were exceeded on the standard limit in all the hospital wards. Data also showed that noise levels were significantly different in each ward among the three shifts working duties. 2. The subjects were all female nurses. They were mostly working in the ICU ward(28.9%). They were 26~30 years old (43.9%), junior college graduates(57.0%), working for 1~5 years(55.1%) as staff-nurse(85.6%). There were no significant differences between hospital wards and general characteristics of nurses. 3. The noise levels perceived by nurses were regarded as 'Highly noisy'(56.4%), especially during the 11:30 and 15:30 (30.2%) o'clock. Data also showed that noise education was not ever given to nurses(89.9%). Nurses also responded that they hardly put an effort to reduce noise level(54.8%). However, there were significant differences between wards and noisy working time, experience of noise education and level of effort for noise reduction. 4. Nurses also perceived the ventilator alarm and EKG-alarm as the most disturbing sounds in the ICU, human voice and telephone ringing in the ER, human voice and EKG-alarming in the NR, human voices and telephone ringing in IM and GS both wards respectively in order. There were significant differences between hospital wards and noise making factors. 5. Nurses were shown that they regarded highly 'Sound reduction of the human voice', 'Careful handling on medical instruments', and 'Immediate appliances on alarming materials' as the practical method for noise management. There were significant differences between hospital wards and behavioral practical efforts for noise management. According to that results, the statistical differences were shown in the 24 hour monitored noise levels in each ward. Also, nurses perceived the noise severity differently and they approached variously on the practical efforts for noise reduction in each ward. Thus, author thinks that concrete and systematic endeavor will be necessary for noise reduction and management in hospitals for better working and healing environment for both of patients and staffs.

  • PDF

A Study of Improving Transmissibility for Grommets in Air conditioner Compressor (에어컨 압축기 진동전달률 개선을 위한 그로메트 연구)

  • Park, Hong-Ul;Lee, Jai-Kwon;Mo, Jin-Yong;Park, Deug-Yong;Han, Hyung-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.651-655
    • /
    • 2004
  • This paper studies the designing method and application for grommets, rubber material used to absorb vibration on the air conditioner compressor. The existing grommet with hardness 40 degrees, EPDM, has the high transmissibility on the compressor that causes additional structure born sound. The problem for EPDM is transformation over long time usage possibly due to its design in which stress is concentrated on a certain position. In order to resolve it, silicon material was previously used with the same design in some models. The vibration performance did improve, but the cost became high. Below are the major developments regarding improvements in compressor rubber material, vibration performance and durability through design change, and new grommet to attain cost reduction. 1 The optimum grommet design for stress even distribution through FEM methods. 2. Comparison for grommet material and design for improved transmissibility. 3. Assess for grommets durability and product applications.

  • PDF

Comparison of Image Quality and Effective Dose by Additional Filtration on Digital Chest Tomosynthesis (Digital Chest Tomosynthesis에서 부가필터에 따른 화질 및 유효선량)

  • Kim, Kye-Sun;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.347-353
    • /
    • 2015
  • The purpose of this study is to suggest proper additional filtration by comparisons patient dose and image quality among additional filters in digital chest tomosynthesis (DTS). We measured the effective dose, dose area product (DAP) by changing thickness of Cu, Al and Ni filter to compare image quality by CD curve and SNR, CNR. Cu, Al and Ni exposure dose were similar thickness 0.3 mm, 3 mm and 0.3 mm respectively. The exposure dose using filter was decreased average about 33.1% than non filter. The DAP value of 0.3 mm Ni were decreased 72.9% compared to non filter and the lowest dose among 3 filter. The effective dose of 0.3 mm Ni were decreased 48% compared to 0.102 mSv effective dose of non filter. At the result of comparison of image quality through CD curve there were similar aspect graph among Cu, Al and Ni. SNR was decreased average 19.07%, CNR was average decreased 18.17% using 3 filters. In conclusion, Ni filtration was considered to be most suitable when considered comprehensive thickness, character, sort of filter, dose reduction and image quality evaluation in DTS.