• Title/Summary/Keyword: Noise Characteristic

Search Result 1,458, Processing Time 0.03 seconds

An Experimental Study on the Characteristic of Porous Concrete using different Aggregates (골재의 종류에 따른 포러스콘크리트의 특성에 관한 실험적 연구)

  • Jung, Si-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.89-96
    • /
    • 2004
  • Porous concrete is used of various parts by advantage of porous. Example of growing of plant is possible, and dwelling of creature, and filter functions of various contaminant, and decrease of noise, and so on. This research is for porous concretes that were used by four aggregate rubble, refreshing aggregate, expanded clay, orchid stone. This research estimate that physical and mechanical characteristics of fresh concrete and hardened concrete. The purpose of this research is to make environment-friendly porous concrete. This research's conclusion is as following : 1. Porous Concrete's slump was measured 12~14cm with rubble, 12~16cm with refreshing aggregate, 11~13cm with expanded clay, 11~13cm with orchid stone. Weight of aggregate was bigger, slump price appeared by bigger thing. Because placed Porous Concrete is low viscosity and small resistance between aggregate, it estimated that have high workability. 2. Porous Concrete's unit weight was measured 1.71~1.75t/$\textrm{m}^3$ with rubble, 1.58~1.62t/$\textrm{m}^3$ with refreshing aggregate, 1.19~1.20t/$\textrm{m}^3$ with expanded clay, 0.98~1.06t/$\textrm{m}^3$ with orchid stone. Showed aspect such as weight of aggregate. 3. Porous Concrete's compressive strength was measured 76~102kgf/$\textrm{cm}^2$ with rubble, 51~60kgf/$\textrm{cm}^2$ with refreshing aggregate, 30~40kgf/$\textrm{cm}^2$ with expanded clay, 13~16kgf/$\textrm{cm}^2$ with orchid stone. 4. Tendency of tensile strength and bending strength showed generally similarly with compressive strength, but showed low value fewer than 15kgf/$\textrm{cm}^2$ Therefore, wire mesh, reinforcing rod, such as establishment of frame is considered to need in reinforcement about tensility or flexures in case receive tensility or produce product of thin absence form. It concludes by speculating on the consequences of extrapolating the results of study to remodelling the office building being already existence.

Analysis of Permanent Magnet Eddy Current Loss by Permanent Magnet Attaching Method of Magnetic Gears (마그네틱 기어의 영구자석 부착방법에 따른 영구자석 와전류손실 분석)

  • Park, Eui-Jong;Kim, Sung-Jin;Jung, Sang-Yong;Kim, Yong-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.911-915
    • /
    • 2017
  • Recently, there has been an increasing interest in the non-contact power transmission method of magnetic gears. Since there is no mechanical contact, noise caused by friction can be reduced, and even if a sudden large force is applied, the impact of the gear is close to zero. Further, since the power is transmitted by the magnetic flux, it has high reliability. However, there is a problem that a loss due to a magnetic field due to use of a magnetic flux. The loss caused by the magnetic field of the magnetic gear is a joule loss called eddy current loss. In addition, the eddy current loss in the magnetic gear largely occurs in the permanent magnet, but it is a fatal loss to the permanent magnet which is vulnerable to heat. Particularly, magnetic gears requiring high torque density use NdFeB series permanent magnets, and this permanent magnets have a characteristic in which the magnetic force decreases as temperature increases. Therefore, in this paper, the eddy current loss of the permanent magnet according to the permanent magnet attaching method is analyzed in order to reduce the eddy current loss of the permanent magnet. We have proposed a structure that can reduce the eddy current loss through the analysis and show the effect of reducing the loss of the proposed structure.

An Efficient Routing Path Search Technique in Power Line Communication (효율적인 전력선통신 라우팅 경로 탐색 기법)

  • Seo, Chung-Ki;Kim, Jun-Ha;Jung, Joonhong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1216-1223
    • /
    • 2018
  • As field of application of AMI, AMR uses the power line as the primary means of communication. PLC has a big merit without installation of the new network for communication in a field using the power line which is the existing equipment. However, there is a serious obstacle in commercialization for the instability by noise and communication environment. Therefore, the technical method for maintaining the communication state which overcome such demerit and was stabilized is required essentially. PLC routing technology is applied with the alternative plan now. The routing technology currently managed by field includes many problems by applying the algorithm of an elementary level. PLC routing path search problem can be modeled with the problem of searching for optimal solution as similar to such as optimal routing problem and TSP(Travelling salesman problem). In this paper, in order to search for a PLC routing path efficiently and to choose the optimal path, GA(Genetic Algorithm) was applied. Although PLC was similar in optimal solution search as compared with typical GA, it also has a difference point by the characteristic of communication, and presented the new methodology over this. Moreover, the validity of application technology was verified by showing the experimental result to which GA is applied and analyzing as compared with the existing algorithm.

New feature and SVM based advanced classification of Computer Graphics and Photographic Images (노이즈 기반의 새로운 피쳐(feature)와 SVM에 기반한 개선된 CG(Computer Graphics) 및 PI(Photographic Images) 판별 방법)

  • Jeong, DooWon;Chung, Hyunji;Hong, Ilyoung;Lee, Sangjin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.2
    • /
    • pp.311-318
    • /
    • 2014
  • As modern computer graphics technology has been developed, it is hard to discriminate computer graphics from photographic images with the naked eye. Advances in graphics technology has brought a lot of convenience to human, it has side effects such as image forgery, malicious edit and fraudulent means. In order to cope with such problems, studies of various algorithms using a feature that represents a characteristic of an image has been processed. In this paper, we verify directly the existing algorithm, and provide new features based a noise that represents the characteristics of the computer graphics well. And this paper introduces the method of using SVM(Support Vector Machine) with features proposed in previous research to improve the discrimination accuracy.

The Multi-layer Fabrication and Characteristic Performance for Dark Current Reduction of Mercury Iodide (Hgl2의 누설전류 저감을 위한 다층구조 제작 및 특성 평가)

  • Kim, Kyung-Jin;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Youl;Cho, Sung-Ho;Kim, Jin-Yung;Mun, Chi-Ung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.388-389
    • /
    • 2005
  • In this paper, the electric properties of mercury Iodide multi-layer samples has been investigated. We measured and analyzed their performance parameters such as the X-ray sensitivity and dark-current for a mercury Iodide multi-layer X-ray detector with a dielectric layer. The digital X-ray image detector can be constructed by integrating photoconduction multi-layer that dielectric layer has characteristics of low dark-current, high X-ray sensitivity. However this process has found to have complexity on the performance of the sample. We have investigate dielectric layer that it substitute dielectric layer for HgO(Mercury Oxide). We have employed two approaches for producing the mercury Iodide sample : 1) Physical Vapor Deposition(PVD) and 2) Particle-In-Binder(PIB). In this paper fabricated by PIB Method with thicknesses ranging from approximately 180um to 240um and we could produce high-quality samples for each technique particular application. As results, the dielectric materials such as HgO between the dielectric layer and the top electrode may reduce the dark-current of the samples. Mercury Iodide multi-layer having HgO has characteristics of low dark-current, high X-ray sensitivity and simple processing. So we can acquired a enhanced signal to noise ratio. In this paper offer the method can reduce the dark-current in the X-ray detector.

  • PDF

Value of Echo-Planar Imaging and MRI Dynamic Study in Differentiation Liver Diseases (간 질환 감별에 있이 MR영상의 역동적 검사와 EPI의 유용성)

  • Park, Byung-Rae
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.73-78
    • /
    • 1997
  • The goal of this paper is that we know the usefulness of echo-planar imaging(EPI) for discriminate between hepatocellular carcinoma(HCC) and hemangioma. We get a time signal intensity curve for liver diseases from the dynamic contrast enhancement images and compared and analyze both the contrast ratio(CR) and the contrast to noise ratio(CNR) using echo planar imaging. The obtained results are follows : 1. Hepatocellular carcinoma was shown the best contrast after about 20 seconds when Is the earlist time in the main artery, and then reduced. The center where is disease was shown the characteristic that the best contrast is appeared after about 35-45 seconds and then slowly reduced. Liver parenchyma was shown the best contrast and reduced after 60 seconds. 2. The peripheral nodular of hemangioma was shown the better contrast soon. On the other hend, the contrast of center where is disease started to increase after 60 seconds and was equal to that of liver parenchyma. Increasing of the contrast continued after. 3. Turbo SE technic was used, the average of CR for hepatocellular carcinoma was $36.7{\pm}1.2$ and the average of CNR was $2.4{\pm}3.2$, while the average of CNR for hemangioma was $54.9{\pm}1.0$ and the average of CNR was $9.7{\pm}1.3$. 4. EPI technic was used, the average of CR for hepatocellular carcinoma was $47.8{\pm}1.2$ and the average of CNR was $3.4{\pm}2.1$, while the average of CNR for hemangioma was $75.7{\pm}2.2$ and the average of CNR was $9.5{\pm}1.1$. According to above we can find that hemangioma is more bright than hepatocellular carcinoma and the difference of brightness between hepatocellular carcinoma and hemangioma is useful sequence.

  • PDF

Measurement of Joint Resistance of $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag Superconducting Tape by Field decay Technique (자장감쇠법을 이용한 $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag 초전도선재의 접합저항 측정)

  • Kim, Jung-Ho;Lee, Seung-Muk;Joo, Jin-Ho
    • Progress in Superconductivity
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • We fabricated a closed coils by using resistive-joint method and the joint resistance of the coils were estimated by field decay technique in liquid nitrogen. We used the Runge-kutta method for the numerical analysis to calculate the decay properties. The closed coil was wound by $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag tape. Both ends the tape were overlapped and soldered to each other. The current was induced in a closed coils by external magnetic flux density. Its decay characteristic was observed by means of measuring the magnetic flux density generated by induced current at the center of the closed coil with hall sensor. The joint resistance was calculated as the ratio of the inductance of the loop to the time constants. The joint resistances were evaluated as a function of critical current of loop, contact length, sweep time, and external magnetic flux density in a contact length of 7 cm. It was observed that joint resistance was dependent on contact length of a closed coil, but independent of critical current, sweep time, and external magnetic flux density. The joint resistance was measured to be higher for a standard four-probe method, compared with that for the field decay technique. This implies that noise of measurement in a standard four-probe method is larger than that of field decay technique. It was estimated that joint resistance was $8.0{\times}10^{-9}{\Omega}$ to $11.4{\times}10^{-9}{\Omega}$ for coils of contact length for 7 cm. It was found that 40Pb/60Sn solder are unsuitable for persistent mode.

SACK-SNOOP Protocol for Wireless TCP Performance Improvement (무선 TCP 성능 향상을 위한 SACK-SNOOP 프로토콜)

  • Ahn, Chi-Hyun;Kim, Hyung-Chul;Woo, Jong-Jung;Kim, Jang-Hyung;Lee, Dae-Young;Jun, Kye-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.392-401
    • /
    • 2007
  • Wireless network has high BER characteristic because of path loss, fading, noise and interference. Many packet losses occur without any congestion in wireless network. Therefore, many wireless TCP algorithms have been proposed. SNOOP, one of wireless TCP algorithms, hides packet losses for Fixed Host and retransmits lost packets in wireless network. However, SNOOP has a weakness for bust errors in wireless network. This paper proposes the SACK-SNOOP to improve TCP performance based on SNOOP and Freeze-TCP that use ZWA messages in wireless network. This message makes FH stop sending packets to MH. BS could retransmit error packets to MH for this time. SACK-SNOOP use improved Selective ACK, thereby reducing the number of packet sequences according to error environment. This method reduces the processing time for generation, transmission, analysis of ACK. This time gain is enough to retransmit local burst errors in wireless link. Furthermore, SACK-SNOOP can manage the retransmitted error by extending delay time to FH. The simulation shows that our proposed protocol is more effective for packet losses in wireless networks.

A study on the work environment and accident exposure status of Tower Crane workers (타워크레인 작업 근로자의 작업환경과 사고 노출 실태에 관한 연구)

  • Choi, Seo-Yeon;Cho, Kee-Hong;Park, Dong-Hyun;Choi, Byung-Gil
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.3
    • /
    • pp.115-123
    • /
    • 2015
  • The study conducted statistical analysis of survey on the 239 workers participating in national Tower Crane installation/dismantlement in order to identify work environment and health hazard exposure of Tower Crane workers. Consequently for work related safety status of Tower Crane workers, the number of installation/dismantlement work was the highest at 15-20 times per month, and safety equipments were not arranged at work and they felt highly anxious when boarding on the Tower Crane. Furthermore, it is found that they feel anxious working in the influence of the weather, noise, vibration, wind, the sun ray, and structure characteristic. They have very low satisfaction in the insecureness of workplace and the work environment, and recognizes that their work affect highly on the health. 81.6% of workers have experienced accident at work, the cause of accidents were mainly due to poor work environment, and the health abnormality they have experienced were mostly fatigue and concentration reduction. For job stress, job demand and conflict in relationship were the highest sections. Total 66.5% of workers complained of musculoskeletal disorder related subjective symptom, and back pain patients were the highest of all groups.

Analysis of Effect of Pantograph Cover on the Current Collection Quality of High Speed Train using Real Train Experiment (실차시험을 통한 팬터그래프 커버가 고속열차의 집전성능에 미치는 영향에 대한 분석)

  • Oh, Hyuck Keun;Kim, Seogwon;Cho, Yong-hyun;Kwak, Minho;Kwon, Sam Young
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.409-416
    • /
    • 2016
  • The contact force characteristic between the pantograph and the catenary wire represents the current collection quality of trains; it should be precisely controlled under international standard. Recently, a noise reduction cover has been installed around the pantograph of high speed trains. However, little study on the contact force by the pantograph cover has been conducted. In this study, the impact on the current collection performance of the pantograph cover was analyzed by dynamic contact force measurement using a next generation high speed train (HEMU-430X). As a result, it was confirmed that the attachment of a pantograph cover could lower the mean contact force by approximately 50N at 300km/h. In addition, the pure difference of the average contact force by the presence of pantograph cover, except for the static pressure, was measured and found to be up to 110N at 300km/h. It was also found that the standard deviation of the contact force of 3~5N could be changed by use of a pantograph cover.