• 제목/요약/키워드: Noise Chamber

검색결과 344건 처리시간 0.032초

ISO 방법론을 이용한 음향 확산체 설계 (Design of the Acoustical Diffuser using the ISO method)

  • 서춘기;이평직;정정호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.29-32
    • /
    • 2008
  • In this study, acoustic diffusers were designed as to the ISO method, which measured the random-incidence scattering coefficient of surfaces in a diffuse field. The diffusers which were made of GFRG (Glass Fiber Reinforced Gypsum), consisted of the cubes with different height and width. The height was from 50 to 250 mm and the maximum height was at the center of the diffusers to provide the early reflections. The surfaces were irregularly designed in order to add the lateral reflections. The scattering coefficient of the diffusers was measured in a 1;10 reverberation chamber, but the absorption coefficient was measured in a real scale reverberation chamber. The result of the scattering coefficient was compared to the hemisphere diffusers and the absorption coefficient was compared to ISO 354 data. To validate the measurement results, the scattering coefficient of the diffusers will be measured in a real scale reverberation chamber.

  • PDF

음향 첨버 내부의 1/3-옥타브밴드 스펙트럼 실시간 제어 시스템 (Real-Time 1/3-Octave Band Spectrum Control System of High Intensity Acoustic Chamber)

  • Kim, Youngkey K.;Kim, Hong-Bae;Moon, Sang-Mu;Woo, Sung-Hyun;Lee, Sang-Seol
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.386.2-386
    • /
    • 2002
  • This paper reports the performance and the Algorithm of an 1/3-octave band spectrum control system. The system is developed to provide various required spectrums in a high intensity acoustic chamber. The required spectrums, which usually comes from launch vehicle specification, starts from 25㎐ band and ends 10,000㎐. Short settling time is required to guarantee the safety of test objects and reduce the amount of operating gas. (omitted)

  • PDF

ISO 방법론 및 1:10 축소잔향실을 이용한 확산률 측정 (Measuring Scattering Coefficient in 1:10 Reverberation Chamber Using the ISO Method)

  • 전진용;이병권;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.252-256
    • /
    • 2001
  • Scattering of surface materials has been known as one of the most important aspects in evaluating the acoustics of concert halls are designed. One of the methods that can reduce the errors in estimating the reverberation time and other acoustic parameters through computer modeling is to calculate scattering coefficient of surface materials. However. so far, no objective and reliable methods measuring scattering coefficient has been suggested. In this situation, ISO has suggested the method of measuring the random-incidence scattering coefficient on surfaces in diffuse field, whereas AES has introduced a method on directional-incidence in free field. In this study, the scattering coefficients of five kinds of hemispheres (1.5, 2.0. 2.5. 3.0. 3.5cm) were measured by using the ISO method in 1:10 reverberation chamber. It was found that 3.0cm hemisphere has the highest scattering coefficient satisfying 95% reliability.

  • PDF

대량생산용 음향방출제품의 돌출음 평가장비 개발 (Development of the evaluation equipment for the prominent discrete tone radiated by acoustic emission products in mass production)

  • 이용관;김선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.76-81
    • /
    • 2012
  • In-process evaluation equipment for the prominent discrete tone (PDT) emitted by small motors or actuators such as HDD(Hard Disk Driver), ODD(Optical Disk Driver) or linear motors has been developed and estimated on the basis of Prominence Ratio (PR) method in ECMA 74. Correlation of the evaluation equipment was performed in comparison with the method by ECMA 74 in anechoic chamber. Coherent function between two systems was applied in order to compensate traceability of ECMA 74 in anechoic chamber. Usability of the developed system with estimated Gage R&R shall be approved with real samples in the mass production line.

  • PDF

단순 확장 관 내부 파티션이 음향 투과손실에 미치는 영향해석 (Influence of Internal Partition of Simple Extension Chamber on the Acoustic Transmission Loss)

  • 박정필;정의봉;안세진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.690-692
    • /
    • 2014
  • To identify characterization of a simple extension chamber that have the two internal partition, produce the curve to estimate the transmission loss without the computer analysis. For helpful for internal optimum design, identify the characteristic of internal partition on transmission loss. Made estimated transmission loss curve by function of relationship of internal partition and transmission. Check the similarity of predicted transmission loss and analysis transmission loss. Usage of the predicted transmission loss made by relationship of internal partition and transmission loss is good information to place the internal partition so as to maximize the transmission loss on target frequency at optimal design on muffler.

  • PDF

Experimental Verification of Transverse Electric Mode Controlled Vacuum Chamber of PLS-II Storage Ring

  • 주영도;하태균
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.229-229
    • /
    • 2012
  • It is significant issue to control the unwanted transverse electric (TE) modes in the vacuum chamber for preventing the position reading noise from the beam position monitor (BPM) of storage ring. We introduce shunt structure to control the frequency distribution of TE resonance modes excited in the vacuum chambers of the Pohang Light Source II (PLS-II). The design of shunt structure is performed using the full three dimensional finite-difference time-domain (FDTD) simulation. It is verified that the sympton of the BPM noise is not oberved up to the beam current of 190 mA in the commmissioning of PLS-II.

  • PDF

패널형 흡음재를 이용한 무향실의 설계 (Anechoic Chamber Design using Broadband Compact Absorber)

  • 두세진;오세웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.393-396
    • /
    • 2003
  • Conventional method for designing and installing anechoic chambers is to utilize porous wedges for the sound absorbers. As cutoff frequency lowers down such as 63Hz or 50Hz, the corresponding long wedges diminish the free field area of the chamber. In this study, a new broadband compact absorber(BCA) is introduced which absorbs acoustic energy down to 50Hz. Most prominent is that it measures only 250mm thick. A freely vibrating panel between the non-fibrous absorbers allows tuned absorption at the low frequency region in addition to the high frequency absorption resulted from the conventional absorber installed at the front. Standing waves at low frequency range are suppressed as the BCA modules which are tuned to the corresponding modes absorb sound energy effectively, resulting in anechoic condition. Not only the low frequency performances, but the high frequency absorption is measured to meet adequate conditions for the anechoic chamber. Realized BCA chambers are presented.

  • PDF

이중챔버를 이용한 공압 가진기의 주파수 범위 확장 (Frequency range expansion of pneumatic exciter by using dual-chamber)

  • 박영우;김광준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.815-824
    • /
    • 2013
  • Pneumatic exciters can be good replacements of electrodynamic, piezoelectric and hydraulic exciters owing to simple structure and large exciting force. One problem to be solved is a slow response caused by compressibility of air. Desirable frequency response characteristics of exciter are constant magnitude and zero degree phase, because users want no time delay between input signal and output force. For this reason, frequency range of pneumatic exciters is limited about 0~1 Hz. Therefore, expansion of frequency range is an important issue when designing the pneumatic exciter. In this paper, the pneumatic exciter which has same structure with active pneumatic isolator is dealt with. The dynamic characteristics are presented, and its limitation of expanding frequency range is shown based on analytical studies. Then the pneumatic exciter with dual-chamber is suggested to overcome this problem. Based on simulation study, a design method is presented.

  • PDF

Effect of Suction Nozzle Modification on the Performance and Aero-acoustic Noise of a Vacuum Cleaner

  • Park, Cheol-Woo;Lee, Sang-Ik;Lee, Sang-Joon
    • Journal of Mechanical Science and Technology
    • /
    • 제18권9호
    • /
    • pp.1648-1660
    • /
    • 2004
  • The suction nozzle of a vacuum cleaner was modified to enhance the power performance and to reduce the airflow-induced acoustic noise. The suction power efficiencies of the vacuum cleaner were measured for various nozzles; (1) original nozzle, (2) original nozzle with modified trench height, (3) original nozzle with modified connecting chamber, and (4) a combination of (2) and (3). In addition, the suction pressure and sound pressure level around the suction nozzle were measured to validate the reduction of acoustic noise. The power efficiency and mean suction pressure increased when the trench height of the suction nozzle was increased. This was attributed to the suppression of the flow separation in the suction channel. Modification of the connecting chamber in the original nozzle, which had an abrupt contraction from a rectangular chamber into a circular pipe, into a smooth converging contraction substantially improved the suction flow into the connecting pipe. When both modifications were applied simultaneously, the resulting suction nozzle was more effective from the viewpoints of aerodynamic power increase and sound pressure level reduction.

Design of shunt structure to avoide TE mode in PLS-II storage ring vacuum chamber

  • 주영도;하태균;박성주;박종도
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.42-42
    • /
    • 2010
  • We, previously, proved that the noise in the vertical readback from some of beam position monitors (BPMs) in the vacuum chamber of Pohang Light Source (PLS) are caused by the transverse electric (TE) longitudinal harmonic resonances. Based on this analysis, we now design the shunt structure to remove the TE mode resonces near the BPMs operation frequency of 500 MHz in the storage ring vacuum chamber of PLS upgrade project (PLS-II). The simulation result and experimental test result will be presented.

  • PDF