• Title/Summary/Keyword: Noise Attenuation

Search Result 477, Processing Time 0.026 seconds

자동차 파워스티어링용 유압호스의 맥동감쇠특성

  • 김도태;이종만;윤인균
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.196-202
    • /
    • 1997
  • A reinforced hydraulic hoses,caiied a resonator hoses,with fixible metal tube are commonly used in automotive power steering hydraulic systems to attenuate and eliminate the objectionable fluid borne noise(pressure ripple) or vibration produced by a pump or steering gear. To achieve better nose attenuation in automotile vehicles, the investigations on propagation and attenuation characteristics of fluid borne pressure ripple in power steering hydraulic ciruit are required. So, this paper descibes a mathematical model of hydraulic hoses to support design the power steering hydraulic circuit and analyze the attenuation characteristics of flow and pressure ripples. The model is based on the transfer matrix approach. The experimental results show that the pulsation attenuation characteristics of hydraulic house is remarkably affected by the flexible metal tube inserted coaxially inside a hydraulic hose with a finite length as well as viscoelastic properties of house wall. It is also shown that the predicted results bymodel proposed here agree well with the measured results over a wide frequency range. These results will assist in the modeling and design of hydraulic hoses, and hear, should provide a means for designing a quieter automotive power steering hydraulic systems.

Attenuation Characteristics of the Buried Steel Water Pipes (지하매설 유체함입 강파이프의 감쇠특성 규명)

  • Park, K.J.;Kang, W.S.;Kim, Y.G.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • The attenuation of the fundamental non-torsional modes that propagate down buried steel water pipes has been studied. The mode shapes, mode attenuation due to leakage into the surrounding medium and the scattering of the modes as they interact with pipe joints and fittings have been investigated. In the low frequency region the mode predicted to dominate over significant propagation distances approximates a plane wave in the water within pipe. The established acoustic technique used to locate leaks in buried steel water pipes assumes that leak noise propagates as a single non-dispersive mode at a velocity related to the low frequency asymptote of this water borne mode.

  • PDF

The Estimation of Sound Attenuation Caused by Duct Silencer Using Sound Intensity Method (음향인텐시티법을 이용한 공조 덕트소음기의 감음성능평가방법에 관한 연구)

  • Kim, Seok-Hong;Son, Jang-Yeol;O, Jae-Eung;Kim, Yeo-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.54-61
    • /
    • 1987
  • This paper is to suggest the test method of sound attenuation caused by absorptive duct silencer using sound intensity method in field. In order to estimate sound attenuation, sound power being radiated from sound power source and duct exhaust terminal was measured by the sound pressure method and sound intensity method in semianechoic and common room. The results of the measured sound attenuation values by sound intensity method are more similar to those of theoretical calculation than those by the sound pressure method. In addition, sound intensity method is much less influenced by sound field condition or continuous background noise than the sound pressure method.

  • PDF

Analysis of Fiber-optic Link Budget for Optically fed Wireless Communication

  • Kim, Jung-Tae
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.1
    • /
    • pp.35-38
    • /
    • 2003
  • Analyses of performance of wireless broadband communication systems employing fiber-optic link have presented. We have analyzed CNR penalty to evaluate system performance by taking into account, radio link considering rainfall attenuation, and optical link considering several carrier-to-noise ratio versus the optical modulation index.

Development of the Soundproof Enclosure for Power Transformers (전력용 변압기 차음실 개발)

  • Kweon, Doug-Jin;Koo, Kyo-Sun;Lee, Wook-Ryun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.107-114
    • /
    • 2009
  • Because of the increase of power demand and expansion of downtown, it is necessary to install the power transformers at the substation in the residential area. But the public complaints have increased due to the noise of the power transformers in the substation. A soundproof wall has been employed to the power transformers in the outdoor substations and a soundproof door, a soundproof shutter and soundproof equipment for wind-path has been employed to power transformers in the indoor substations in order to isolate sound propagation from the noise of the power transformers. But the noise reduction results of these methods are not satisfied. In this study, a soundproof enclosure is developed to effectively isolate sound propagation from the noise of the power transformers. The performance of the sound attenuation of the developed soundproof enclosure is verified in a 154[kV] transformer. As a result, 15[dB] sound attenuation in 120[Hz] component is achieved by applying the developed soundproof enclosure to a 154[kV] transformer.

System Analysis for Receiving Performance Improvement of Mobile Station in PCS (개인휴대통신에서 이동국의 수신성능개선을 위한 시스템 분석)

  • Ju, Jae-Han;Park, Se-Seung;Park, Jong-An;Cheon, Jong-Hun
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.1
    • /
    • pp.159-166
    • /
    • 1999
  • In this paper, we examined noise figure and the 3rd order intercept point in sensitivity single tone desensitization, and response attenuation by intermodulation spurious of receiver and also analyzed them through simulation based on J-STD-0.18, which is the minimum specification of PCS mobile station. The result of simulation was as follows ; In sensitivity specification, the total noise figure was 5.99dB and the 3rd order intercept point was -33.979dB. Ins ingle tone desensitization and intermodulation spurious response attenuation specification, the total noise figure was 6.375dB and the 3rd order intercept point was -26.99dBm. When there is an interference tone, the nosie figure and the 3rd order intercept point have been increasedly 0.367dB respectively, compared wit that of no interference tone. Because the amount of increase in the 3rd order intercept point was highly raised more than that of noise figure, mixer, closely related to interference tone should be specified in high 3rd order intercept point. At a frequency spacing of 1.25MHz and 2.05MHz from center frequency in IF SAW filter, attenuation should be more than 45dB.

  • PDF

A Study on Sound Attenuation of Plant Noise by Enclosure (방음실에 의한 공장설비 소음의 감쇠 효과에 관한 연구)

  • 윤세철;이해경
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.119-124
    • /
    • 1994
  • The considerations in the noise control by enclosure are the rise of temperature and sound pressure, transmission loss, absorption coefficient of the materials, the structure of the soundproof panels, an opening and coincidence frequency. But it is very difficult that we obtain the accurate data about those in design, so, the noise reduction after enclosing does not correspond with the calculation. The difference of the noise reduction between the calculation and the measurement was 8.2dBA, and we can obtain the approximate result as the following formula which correct 10dBA, safely.

  • PDF